UH310 Series Athalon® High Pressure Filters product photo Primary L

UH310 Series Athalon® High Pressure Filters

Athalon® maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.

Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)

  • Keeps fluids the cleanest, longest, for the greatest value
  • Provides consistent, reliable, protection of system components over the full service life of the filter element
  • Rapidly achieves and sustains required fluid system cleanliness
  • Delivers maximum filter capacity in the smallest footprint
  • Prevents electrostatic discharge from damaging your filter and degrading your fluid

Features

  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Pall Stress-Resistant Technology (SRT) Media
  • Coreless filter element configuration
  • Low clean pressure drop for low energy operation


Contact Us
* Required

Documents

Datasheets

Download: English | German

Description

Athalon® maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.

Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)

  • Keeps fluids the cleanest, longest, for the greatest value
  • Provides consistent, reliable, protection of system components over the full service life of the filter element
  • Rapidly achieves and sustains required fluid system cleanliness
  • Delivers maximum filter capacity in the smallest footprint
  • Prevents electrostatic discharge from damaging your filter and degrading your fluid

Features

  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Pall Stress-Resistant Technology (SRT) Media
  • Coreless filter element configuration
  • Low clean pressure drop for low energy operation

Specifications

Specifications Filter Housing

  • Flows to 600 L/min (160 US gpm)
  • Pressures to 414 bar (6000 psi)
  • Port size 1¼", 1½" and 2"
  • Rated Fatigue Pressure:
    0-240 bar (3500 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million cycles), verified by testing at 0-280 bar (4050 psi) for 1 million cycles. Not applicable to 'D' and 'F' port options. Contact Pall for applications with higher pressures at lower cycles
  • Filter Element Burst Pressure:
    10 bard (150 psid)
  • Fluid Compatibility:
    Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals:
    -29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F)
    60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids
  • Bypass Valve Setting:
    4.5 bard (65 psid)
  • Indicator Pressure Setting:
    3.5 bard (50 psid)
  • Materials of Construction:
    Head and Cover: Ductile Cast Iron
    Tube: Carbon steel
  • Filter Element :
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design

Dimensional Drawings

Dimensions in mm (inches)
 
Length Code Overall length mm (in) Cover Service Element Removal Clearance mm (in) Head Service Element Removal Clearance mm (in) Empty Weight kg (lb)
08 476 (18.74) 248 (9.76) 305 (12) 29.7 (65.5)
13 612 (24.09) 383 (15.08) 440 (17.32) 34.5 (76.1)
20 782 (30.79) 553 (21.77) N/A 40.6 (89.5)
40 1290 (50.79) 1061 (41.78) N/A 58.8 (129.6)
 


Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

310 Series Filter Elements – bard/1000 L/min (psid/US gpm)
 
Length Code AZ AP AN AS AT
08 085.52 (0.302) 2.30 (0.126) 1.82 (0.100) 1.32 (0.072) 0.82 (0.045)
13 3.31 (0.182) 1.38 (0.076) 1.09 (0.060) 0.79 (0.043) 0.49 (0.027)
20 2.18 (0.120) 0.91 (0.050) 0.72 (0.040) 0.52 (0.029) 0.33 (0.018)
40 1.10 (0.060) 0.46 (0.025) 0.36 (0.020) 0.26 (0.014) 0.16 (0.009)
 

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm

Sample ΔP calculation

UH310 Series 13" length housing with G24 (1 1/2"SAE)) split flange ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP
= ΔP housing + ΔP element
= (0.33 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.44 (housing) + 0.68 bard (element)
= 1.12 bard (16.2 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

For new installations, select one complete part number from each section below

Section 1 Housing P/N: UH310 [Table A] [Table B]

Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.

 
Table 1 Table 2
Port & Length Options
Tables 1, 2 and 3
Bypass & Orientation Options
Tables 4
A2008Z C, G or GH
A2013Z C, G or GH
A2020Z C or G
A2408Z C, G or GH
A2413Z C, G or GH
A2420Z C or G;
C2008Z C, G or GH
C2013Z C, G or GH
C2020Z C or G
C2408Z C, G or GH
C2413Z C, G or GH
C2420Z C or G
C3213Z C, G or GH
C3220Z C or G
D2408Z G or GH
D2413Z G or GH
D2420Z G
D3213Z G or GH
D3220Z G
E2008Z C, G or GH
E2013Z C, G or GH
E2020Z C or G
E2408Z C, G or GH
E2413Z C, G or GH
E2420Z C or G
E3213Z C, G or GH
E3220Z C or G
E3240Z C or G
F2008Z G or GH
F2013Z G or GH
F2020Z G
F2408Z G or GH
F2413Z G or GH
F2420Z G
F3213Z G or GH
F3220Z G
G2008Z C, G or GH
G2013Z C, G or GH
G2020Z C or G
G2408Z C, G or GH
G2413Z C, G or GH
G2420Z C or G
G3213Z C, G or GH
G3220Z C or G
G3240Z C or G
 

Table 1: Housing Port Options

 
Code Port Style Max. Operating Pressure
A SAE J1926 straight thread 414 bar (6000 psi)
C BSP ISO 228 threads 414 bar (6000 psi)
D Flange J518C code 61 207 bar (3000 psi)
E Flange J518C code 62 414 bar (6000 psi)
F ISO 6162 split flange 250 bar (3625 psi)
G ISO 6162 split flange 400 bar (5800 psi)
 

Table 2: Port Size

 
Code Port Style
20 1 1/4" nominal
24 1 1/2" nominal
32 2" nominal
 

Table 3: Housing Length and Seal Options

 
Code Length and Seal Material
08Z 8" nominal length, fluorocarbon seals
13Z 13" nominal length, fluorocarbon seals
20Z 20" nominal length, fluorocarbon seals
40Z 40" nominal length, fluorocarbon seals
 

Table 4: Bypass Valve and Service Options

 
Code Bypass Valve and Service Type
C 4.5 bard (65 psid) bypass valve with reverse flow, Cap service
G 4.5 bard (65 psid) bypass valve, Cap service
GH 4.5 bard (65 psid) bypass valve, Head service
 

Seal Kit P/N: SH 310 SKZ

*Other seal material options are available; Contact Pall.

Section 2 Element P/N: UE 310 [Table 5] [Table 3]

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 5: Filter Element Options

 
Code ßx(c) ≥2000 based on ISO 16889 CST Rating*
AZ 3 07/04/01
AP 5 11/08/03
AN 7 13/09/04
AS 12 15/11/06
AT 25 16/14/08
 

Section 3 (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)

Differential Pressure Indicator P/N: RC [Table 6]  Z 091 Z [Table 7]

Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 6: Indicator Options

For applications with operating conditions less than 200 bar (3000 psi)
 
Code Brass Option indicator
A218M Electrical switch (SPDT) with Hirschmann connector
A218R Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators
A219D Visual indicator
 

For applications with operating conditions greater than 200 bar (3000 psi)
 
Code Stainless Steel indicator
778NZ Visual filter with thermal lockout
861CZ Electrical Switch (SPDT) with 6" leads
861CZ* Electrical switch (SPDT) with Hirschmann connector
771BZ Electrical switch (SPDT) with 3-pin
 
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 7.

Table 7: Differential Pressure Indicator Material

 
Code Pressure Setting
Omit Brass Indicator: use at operating pressures < 200 bar (3000 psi)
SS Stainless Steel Indicator: use at operating pressures > 200 bar (3000 psi)
 
Other setting options are available; contact Pall.

Reviews