8900/04/10/14 Series Rotolok Filter Assemblies product photo Primary L

8900/04/10/14 Series Rotolok Filter Assemblies

Featuring Coreless Element Technology
Flows to 200 gpm (755 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 2" and 2-1/2"

Please Note:
The 8900 series filter assemblies are no longer available and are being replaced with Ultipleat® UR319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.


問い合わせ
* Required

概要

Featuring Coreless Element Technology
Flows to 200 gpm (755 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 2" and 2-1/2"

Please Note:
The 8900 series filter assemblies are no longer available and are being replaced with Ultipleat® UR319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.

仕様

Features

  • Optional Differential Pressure Devices
  • Full Flow Fast Response Bypass Valve
  • Easy Service Rotolok Ring
  • Drawn Steel Bowl
  • Optional Anti-Backflow Valve (not shown).  Prevents drainage of reservoir or lines where filter is mounted below fluid level
  • High Strength Fatigue Rated Housing
  • Gray Cast Iron Head
  • O-Ring Seals
  • Ultipor® III Element

Maximum Allowable Working Pressure:

600 psi (41 bar)

Fatigue Pressure Rating:

Rated Fatigue pressure: 400 psi (28 bar) 107 cycles per NFPA T2.6.1 - 1974

Temperature Range:

Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

S length– 26 lbs. (12 kg)
T length– 28 lbs. (13 kg)
U length– 30 lbs. (14 kg)

Filter Element Collapse Pressure:

150 psid (10 bar)

Dimensional Drawings

 

性能

Element Pressure Drop Factor.

Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8900 Series Element P factor (psid/gpm)
 
LengthKZKPKNKSKT
           
8" 0.30 0.14 0.12 0.09 0.06
           
13" 0.19 0.09 0.07 0.05 0.04
           
16" 0.14 0.07 0.05 0.04 0.03
 

 

8904 Series Element P factor (psid/gpm)
 
LengthKZKPKNKSKT
           
8" 0.36 0.17 0.14 0.10 0.07
           
13" 0.21 0.10 0.08 0.06 0.04
           
16" 0.15 0.07 0.06 0.04 0.03
 

製品カテゴリー

Housings, Vessels, or Assemblies

型式

Assembly P/N:     

H

89

 

 

 

Table1

 

Table2
Table3
Table4
Table5
Table6
Table7
Table8
Table9
Table10
 


Element P/N:       

HC  8900 (8900/10 Housing)

   F   

 

 

 

 

 

HC  8904 (8904/14 Housing)

 
Table5
Table6
Table1
 

 

 

 



Note:
Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options
 
CodeSeals
   
H Nitrile
   
Z Fluorocarbon
 


 

Table 2: Element/Head Options
 
CodeOption*
   
00 'L' (standard element)
   
04 'L' (coreless element)
   
10 'T' (standard element)
   
14 'T' (coreless element)
 
*"L" = L Head. "T" = T Head.



Table 3: Port Style Options
 
CodePort Style
   
A SAE J514 straight thread
   
B NPT tapered pipe thread
   
D Flange SAE J518c-code 61
 


 

Table 4: Port Size Options
 
CodeSize
   
32 2"
   
40* 2-1/2"
 
* D ports only.



Table 5: Filter Element Options
 

Code

ßx  200

ßx(c) = 1000

     

KZ

<1

2.5

     

KP

3

5

     

KN

6

7

     

KS

12

12

     

KT

25

22

 

 

Table 6: Length Options*
 

Assembly Code

Element Code**

   

S

8

   

T

13

   

U

16

 
* Use code in second column for element part no.
** Nominal length in inches.



Table 7: Bypass Valve Options
 
CodeDescription
   
A 25 psid
   
B 50 psid
   
W* Non-bypass
   
8* 25 psid with ABFV
   
9* 50 psid with ABFV
   
V* Non-bypass with ABFV
 
* ABFV - Anti-backflow valve, available for 'T' head units only: 8910/14.



Table 8: Differential Pressure Device Options
 

Code

Description

   

P

Visual indicator with thermal lockout

   

D

Visual indicator with no thermal lockout

   

L

Electrical switch (SPDT) with 6" leads

   

T

Electrical switch with DIN connector

   

M

'T' type switch with matching wiring cap

   

S

Electrical switch with MS receptacle

   

V

Combined visual/electrical with DIN connector

   

B

Bleed plug and seal in place of indicator

   

2

'P' and 'L'

   

3

'P' and 'S'

 


Table 9: Auxiliary Ports
 

Code

Auxiliary Ports

   

N

Unmachined

   

B

Both† sides

   

R*

Right only†

   

L*

Left only†

 
* Special order-contact factory.
† Shipping plugs provided only.


Table 10: Ejector Spring Options
 

Code

Description

   

N

No ejector spring

   

S

Ejector spring

 

レビュー

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.