6500 Series Filter Assemblies product photo Primary L

6500 Series Filter Assemblies

Flows to 300 gpm (1135 L/min)
Pressures to
250 psi (17 bar)
Port sizes:
2" and 2-1/2"

Please Note:
The 6500 series filter assemblies are no longer available and are being replaced with Ultipleat® UT319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.


問い合わせ
* Required

概要

Flows to 300 gpm (1135 L/min)
Pressures to
250 psi (17 bar)
Port sizes:
2" and 2-1/2"

Please Note:
The 6500 series filter assemblies are no longer available and are being replaced with Ultipleat® UT319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.

仕様

Maximum Allowable Working Pressure:

250 psi (17 bar)

Fatigue Pressure Rating:

Rated Fatigue pressure: 250 psi (17 bar) 107 cycles per NFPA T2.6.1 - 1974

Temperature Range:

Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

T length– 26.0 lbs. (11.8 kg)
U length– 30.0 lbs. (13.6 kg)
V length– 35.5 lbs. (16.1 kg)

Filter Element Collapse Pressure:

150 psid (10 bar)

Caution:

120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings



 



 

性能

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific gravity.

 
 
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor

Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

  
 
6500 Series Element P factor (psid/gpm)
 

Length

DP
DN
DS
DT
         
13"
0.14
0.08
0.06
0.05
         
16"
0.11
0.06
0.04
0.04
         
26"
0.08
0.04
0.03
0.02
 

 

製品カテゴリー

Housings, Vessels, or Assemblies

型式

Assembly P/N:     

H

6500

 

 

Table1

 

Table2
Table3
Table4
Table5
Table6
Table7
Table8
Table9


Element P/N:       

HC

6500F

 

 

 

 

 

 

 

Table4
Table5
Table1
 

 

 

 


 
Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS 
 
Code
Seals
   
H
Nitrile
   
Z
Fluorocarbon
 
 
 
 

TABLE 2: PORT STYLE OPTIONS

 
Code
Port Style
   
A
SAE J514 straight thread
   
B
NPT
   
D
Flange SAE J518c-Code 61
 
 

 

TABLE 3: INLET PORT SIZE OPTIONS
 
Code
Size
   
32
2"
   
40
2-1/2"
 
 


 

TABLE 4: FILTER ELEMENT OPTIONS
 
Code
ßx  200
ßx(c)=1000
     
DP
3
5
     
DN
6
7
     
DS
12
12
     
DT
25
22
 
 


 

TABLE 5: LENGTH OPTIONS*
 
Assembly Code
Element Code**
   
T
13
   
U
16
   
V
26
 
* Use code in second column for element part no.
** Nominal length in inches.
 
TABLE 6: BYPASS VALVE OPTIONS
 
Code
Description
   
A
25 psid
   
B
50 psid
   
W
Non-bypass
   
8
25 psid with ABFV*
   
9
50 psid with ABFV
   

V

Non-bypass with ABFV
 
* ABFV- Anti-backflow valve.


 

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
 
Code
Description
   
PM
Visual indicator with thermal lockout
   
DM
Visual indicator with no thermal lockout
   
LL
Electrical switch (SPDT) with 6" leads
   
TL
Electrical switch with DIN connector
   
ML
'TL' type switch with matching wiring cap
   
SL
Electrical switch with MS receptacle
   
BL
Plug in place of indicator
   
PL
Same as PM but with plastic body
   
DL
Same as DM but with plastic body
 
Indicator and switch pressure settings
16 psid with "A"and "8" bypass valve
35 psid with "W," "V," "B," and "9" option.


 

TABLE 8: SECONDARY PORT OPTIONS

 
Code
Port Option
Port Size
     
S
Port machined
1-1/2"
     
N
Non-machined
-
 
Port opposite main inlet in style consistent with main inlet port (see Table 2).

 

 

TABLE 9: AUXILIARY PORT OPTIONS 
 
Code
Port Option
Port Size
     
R
Right side*
1-1/4"
     
L
Left side*
1-1/4"
     
B
Both
1-1/4"
     
N
Non-machined
-
 
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2).

レビュー

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.