Combining fixed Docking Station and exchangeable Filter Capsule for up to 2 months use
The QPoint® Tap Water Filter Assembly with exchangeable Filter Capsule for up to 62 day (2 months) use provides 0.2 μm sterilizing-grade filtered water at the Point-of-Use.The high technology integrated prefiltration layer delivers exceptional particulate trapping capacity with good flow rates, and protects the proven double layer sterilizing grade membranes enabling long performance life. The Filter Capsule retains fungi, protozoa and bacteria such as Legionella spp., Pseudomonas spp., non-tuberculous Mycobacteria and Escherichia coli without volume restriction.
The smooth, chrome finish Docking Station is hygienically designed, and will fit to all standard tap water outlets. The combination of this fixed Docking Station with the disposable Filter Capsule is compact, reduces waste, reduces costs and improves logistics for the user.
Features | Benefits |
Secure double layer 0.2 μm sterilizing grade filter membranes | Retains microorganisms without volume restriction |
Fixed docking station and exchangeable filter capsule | Waste reduction, cost reduction and improved logistics |
Improved pre-filtration | Higher dirt capacity for better flow rates |
Intelligent protection from back splash | Minimizes retrograde contamination |
Reuseable and recyclable materials | Environmentally friendly |
규격사양
QPoint Docking Station - Tap Assembly (QDTC)
Diameter (nominal) | 3.5 in. (88 mm) |
Weight (nominal) | 3.0 oz (84 g) |
Temperature | Continuous influent temperature 140 °F (60 °C) Maximum influent temperature 167 °F (75 °C) for a total cumulative period of 90 minutes over the life of each Filter Capsule |
Maximum Operating Pressure | 5 bar (75 psi) at continuous 140 °F (60 °C) influent temperature |
Cleansing and Disinfection | External surfaces may be cleaned using common sanitising agents During routine water system disinfection the Docking Station with attached Filter Capsule can be left in place to enable the outlet to be flushed |
Main Materials of Construction | Polycarbonate/Acrylonitrile Butadiene Styrene (51%), Glass Filled Nylon (22%), Polyester (20%), Stainless Steel (4%) |
Packaging | Recycled cardboard outer packaging |
Pall QPoint Docking Station - Tap Assembly (QDTC) Materials of Construction (% by weight)
Polycarbonate/Acrylonitrile Butadiene Styrene | 51% |
Glass Filled Nylon | 22% |
Polyester | 20% |
Stainless Steel | 4% |
Ethylene-Propylene-Diene-Monomer | 2% |
Polycarbonate | 0.7% |
Silicone | 0.3% |
Brass | 0.1% |
QPoint Filter Capsule (QJ212U, QJ22U)
Flow Rates (nominal) | 5.7 L / min at 1 bar 13.1 L / min at 3 bar 18.8 L / min at 5 bar |
(1.5 gal / min at 15 psi) (3.5 gal / min at 44 psi) (5.0 gal / min at 75 psi) |
Diameter (nominal) | 3.5 in. (88 mm) | |
Weight (nominal) | 4.2 oz (119 g) | |
Temperature | Continuous influent temperature 140 °F (60 °C) Maximum influent temperature 167 °F (75 °C) for a total cumulative period of 90 minutes over the life of each Filter Capsule |
|
Maximum Operating Pressure | 5 bar (75 psi) at continuous 140 °F (60 °C) influent temperature | |
Sanitisation | Compatible and complementary to common surface and systemic disinfection programs | |
Main Materials of Construction | Polyester (83.4%), Polypropylene (10.1%), Polyethersulphone (6.5%), (Recyclable) | |
Packaging | Recycled cardboard outer packaging. Ethylene Vinyl Acete (EVA) plastic film blister. Tyvek polyethylene lid | |
Pall QPoint Filter Capsule (QJ212U, QJ22U) Materials of Construction
(% by weight)
Polyester | 83% |
Polypropylene | 10.5% |
Polyethersulphone | 6.5% |
종류
Point-of-Use Filters
사용
Filtration, Removal, Retention
추가 정보
Pall QPoint& Docking Station (QDTC)
Pictorial Installation GuideDescription
The Pall QPoint Docking Station - Tap Assembly with Quick Connect Inlet is supplied non-sterile.For full details, refer to the Instructions for Use.
![]() |
![]() |
![]() |
|
|
|
![]() |
![]() |
|
|
|
Disconnection
- Press latch on Quick Connect Adaptor to release Docking Station and remove.
Disposal
- The used Docking Station should be disposed of according to local procedures.
Pall QPoint& Filter Capsule (QJ212U, QJ22U)
Pictorial Installation GuideDescription
The Pall QPoint Filter Capsules are:- Provided sterile.
- Disposable and may be used for up to 62 days (2 months) following initial connection.
![]() |
![]() |
![]() |
|
|
|
![]() |
![]() |
![]() |
|
|
|
![]() |
||
The Filter Capsule should not be
|
Disconnection
- Lift release button on the Docking Station to disengage Filter Capsule, and turn Filter Capsule to remove.
Disposal
- The used Filter Capsule should be disposed of according to local procedures. All materials are suitable for plastics recycling, as per local guidelines.
Systemic Chemical Disinfection
A wide variety of systemic chemical treatments are used to mitigate microbial contamination within potable water supplies to hospitals, hotels, leisure centres, schools, apartment blocks and other building complexes. Such chemical treatments may be used in conjunction with Pall Point of Use Water Filters as part of the engineering solution.Testing has been performed to support compatibility of Pall QPoint Filter Capsules (QJ212U, QJ22U) with a range of common systemic chemical treatments, particularly shock treatments completed during periods of critical water system contamination.
Active chlorine at 100 parts per million (ppm)
Following exposure to active chlorine for 1 hour at 22 °C (72 °F) all Filter Capsules passed. No visual abnormalities were observed.Continuous treatment with active chlorine for up to 62 days (at 1-7 ppm)
Following exposure at 1-7 ppm active chlorine for 62 days at 22°C (72 °F) all Filter Capsules passed integrity test. No visual abnormalities were observed.Shock treatment with pH > 12
Following exposure to pH>12 for 1 hour at 22 °C (72 °F) all Filter Capsules passed integrity test. No visual abnormalities were observed.Shock treatment with peracetic acid (1000 ppm)
Following exposure to 1000 ppm peracetic acid for 2 hours at 60 °C (140 °F) all Filter Capsules passed integrity test. No visual abnormalities were observed.Conclusion
Pall QPoint Filter Capsules maintain their filter integrity and are compatible with shock treatment of 100 ppm active chlorine for 1 hour, continuous active chlorine treatment of up to 1-7 ppm for 62 days, pH>12 for one hour or 1000 ppm peracetic acid for 2 hours.Surface Disinfection
- If a filter is visibly, or known to have been contaminated, it should be replaced.
- QPoint Filter Capsules should not come into contact with contaminated surfaces or cloths.
- If there is a local Standard Operating Procedure in place for Filter Capsule cleansing and hygiene, which includes a new or sterile wipe/cloth for each filter outlet, then the external surfaces of the Filter Capsule (QJ212U, QJ22U) may be cleansed with the following common sanitising solutions containing Iso-Propyl Alcohol, Quaternary Ammonium Compounds, Benzyl Ammonium Compounds, Iodides and non-ionic surfactants. The following solution compositions (qualitative compositions) have been tested:
- Solution A: n-propanol (29%), propionic quaternary ammoniums, polhexanide.
- Solution B: glycolic acid, propionic quaternary ammoniums, n-propanol, non-ionic surfactants, fragrance, colour.
- Solution C: propionic quaternary ammoniums, guanidium acetate, n-propanol, non-ionic surfactants, excipients.
- Solution D: alkyl (60% C14, 30% C16, 5% C12, 5% C18) dimethyl benzyl ammonium chloride (2.25%), alkyl (68% C12, 32% C14) dimethylethylbenzyl ammonium chloride (2.25%), inert ingredients (95.5%).
- Solution E: di-isobutylphenoxyethoxyethyl dimethyl benzyl ammonium chloride (0.28%), isopropanol (17.2%), inert ingredients (82.52%).
- Solution F: povidone iodine (4%), excipients.
- Solution G: n,n-didecyl-n-methyl-poly(oxyethyl) ammonium propionate (2.5-10%), sodium n-lauryl b-iminodipropionate (2.5-10%), ethoxylated isotridecanol (2.5-10%), monopropylene glycol (10-25%), ethane-1,2-diol,homopolymere (0-2.5%), polyhexamethylene biguanide hydrochloride (0-2.5%).
- Periodic wiping or spraying of the housing / outlet with the solutions listed above does not adversely affect the polyester (polybutylterepthalate) housing material of the QPoint Filter Capsules. At no point should the Filter Capsule be disconnected during cleansing.
주문정보
Reorder Code | Product Description | Packaging |
Docking Station | ||
QDTC | Tap Assembly with Quick Connect Inlet | 1 unit/pkg |
Filter Capsules | ||
QJ212U | Jet Outlet, 0.2 μm Filter | 12 units/pkg |
QJ22U | Jet Outlet, 0.2 μm Filter | 2 units/pkg |
Quick Connect Adaptors | ||
TAP1/2MN | 1/2 inch, male thread, non-valved | 1 unit |
TAP1/2MV | 1/2 inch, male thread, valved | 1 unit |
TAP1/2FN | 1/2 inch, female thread, non-valved | 1 unit |
TAP1/2FV | 1/2 inch, female thread, valved | 1 unit |
TAP22FN | 22 mm, female thread, non-valved | 1 unit |
TAP22FV | 22 mm, female thread, valved | 1 unit |
TAP24MN | 24 mm, male thread, non-valved | 1 unit |
TAP24MV | 24 mm, male thread, valved | 1 unit |
TAPUC | Universal (15 – 29 mm), non-threaded | 1 unit |
TAP21MN | 21 mm, male thread, non-valved | 1 unit |
TAP21MV | 21 mm, male thread, valved | 1 unit |