Marksman™ XLD High Flow Series Filter Elements product photo Primary L

Marksman™ XLD High Flow Series Filter Elements

High Flow, High Capacity Pleated Polypropylene Filter Elements

  • Large cartridge geometry
  • Innovative joining of depth and pleated technologies
  • High flow capacity1
  • Poly-Fine® Extended Life Depth (XLD) proprietary media for highly consistent filtration
  • Inside to out flow traps contaminant inside the element
  • Fits into standard Pall High Flow filter housings

Housing Design

Three configurations are available: horizontal, vertical and centerpipe design.

The in-line horizontal configuration eliminates the need for a platform, or ladder, to remove the filters from the housing.

Vertical vessels may be more appropriate when floor space is limited. However, a platform may be needed to easily remove the elements.

In both the standard horizontal and vertical configurations, the inlet pipe is located between the filter element tubesheet and housing lid. The larger the vessel diameter, the longer the distance to reach in and remove the elements from the vessel. In a centerpipe vessel the housing lid is closer to the filter tubesheet. When the lid is opened the filters are easily accessible for installation and removal.


  • Designed to the ASME, section VIII, division 1 code
  • Maximum differential pressure across tubesheet: 75 psid (5.2 bar) maximum
  • Standard housing gasket: spiral wound 304 stainless steel mineral fiber
  • Carbon steel exterior surfaces: sandblasted and coated with an inorganic zinc
  • Vent and drains: 1 inch FNPT
  • Corrosion allowance: 1⁄8 inch for carbon steel  only

Filter Installation and Filter Seal Mechanism

To install a filter element, remove the element hold down plate by lifting it off the locating pins. Lubricate the O-ring on the open-end of the filter with a compatible fluid, and slide the closed end of the filter into the perforated cage, which is welded to the tubesheet. Seat the elements in place by pressing down on the open-end of the filter until the element is snug in the tubesheet. This provides a seal between the filter and housing via the filter O-ring. The open-end cap must be below the tubesheet surface. After installing all the filter cartridges, reinstall and secure the element hold down plate by guiding it over the locating pins on the tubesheet. The purpose of the hold down plate is to prevent the elements from becoming dislodged in the event of reverse flow.

A filter element tool is provided with each housing to aid with the installation and removal of the filter cartridges. This tool eliminates the need for an operator to reach within the filter vessel to either remove or install the filters.


Marksman XLD High Flow Filter System Reduces Costs

Begin reducing your capital and operating costs today. Contact your local Pall distributor, or call Pall directly for a system quotation.



Contact Us
* Required

Documents

Datasheets

Download: English | English | Japanese

Description

High Flow, High Capacity Pleated Polypropylene Filter Elements

  • Large cartridge geometry
  • Innovative joining of depth and pleated technologies
  • High flow capacity1
  • Poly-Fine® Extended Life Depth (XLD) proprietary media for highly consistent filtration
  • Inside to out flow traps contaminant inside the element
  • Fits into standard Pall High Flow filter housings

Housing Design

Three configurations are available: horizontal, vertical and centerpipe design.

The in-line horizontal configuration eliminates the need for a platform, or ladder, to remove the filters from the housing.

Vertical vessels may be more appropriate when floor space is limited. However, a platform may be needed to easily remove the elements.

In both the standard horizontal and vertical configurations, the inlet pipe is located between the filter element tubesheet and housing lid. The larger the vessel diameter, the longer the distance to reach in and remove the elements from the vessel. In a centerpipe vessel the housing lid is closer to the filter tubesheet. When the lid is opened the filters are easily accessible for installation and removal.


  • Designed to the ASME, section VIII, division 1 code
  • Maximum differential pressure across tubesheet: 75 psid (5.2 bar) maximum
  • Standard housing gasket: spiral wound 304 stainless steel mineral fiber
  • Carbon steel exterior surfaces: sandblasted and coated with an inorganic zinc
  • Vent and drains: 1 inch FNPT
  • Corrosion allowance: 1⁄8 inch for carbon steel  only

Filter Installation and Filter Seal Mechanism

To install a filter element, remove the element hold down plate by lifting it off the locating pins. Lubricate the O-ring on the open-end of the filter with a compatible fluid, and slide the closed end of the filter into the perforated cage, which is welded to the tubesheet. Seat the elements in place by pressing down on the open-end of the filter until the element is snug in the tubesheet. This provides a seal between the filter and housing via the filter O-ring. The open-end cap must be below the tubesheet surface. After installing all the filter cartridges, reinstall and secure the element hold down plate by guiding it over the locating pins on the tubesheet. The purpose of the hold down plate is to prevent the elements from becoming dislodged in the event of reverse flow.

A filter element tool is provided with each housing to aid with the installation and removal of the filter cartridges. This tool eliminates the need for an operator to reach within the filter vessel to either remove or install the filters.


Marksman XLD High Flow Filter System Reduces Costs

Begin reducing your capital and operating costs today. Contact your local Pall distributor, or call Pall directly for a system quotation.

Specifications

Performance Specifications

Filter Grades:

1.5, 3, 4.5, 10, 20, 30, 70 micron (μm)

Maximum Operating Differential Pressure:2

50 psid (3.4 bard) @ 68°F (20°C)
35 psid (2.4 bard) @ 160°F (71°C)

Product Specifications

Materials of Construction:

Filter Medium: Polypropylene
Support: Polypropylene
End caps: 10% glass fiber reinforced polypropylene
Center core (60" length only): Polypropylene
O-ring/U-cup seal options: Ethylene propylene, Fluorocarbon elastomer, Nitrile

Dimensions (nominal):

Cartridge length: 20" (508 mm),
40" (1016 mm),
60" (1524 mm)
Cartridge max. OD: 6.3" (160 mm)
Medium OD: 5.9" (150 mm)
Medium ID: 3.5" (89 mm)


1 Maximum flow through the filter element is application dependent. Pall suggests not to exceed 500 gpm (1892 lpm) per 60" element; 333 gpm (1260 lpm) per 40" element; 167 gpm (632 lpm) per 20" element, as good application practice.
2 Maximum operating differential pressure recommended for inside to out flow only.


Horizontal Housings


Horizontal Housings, Centerpipe Design

Performance

Particle Removal Ratings (μm)3

 
Grade ≥ 90% Removal (Beta 10)
XLDM1.5 1.5 μm
XLDM 3 3 μm
XLDM 4.5 4.5 μm
XLDM 10 10 μm
XLDM 20 20 μm
XLDM 30 30 μm
XLDM 70 70 μm
 


Typical Liquid Flow Specifications

 
Filter
Grade
PSID per 1 GPM (mbard/lpm) -
Water @ 68°F (20°C)4
20" 40" 60"
XLDM 1.5 0.0278
(0.5058)
0.0139
(0.2529)
0.0093
(0.1686)
XLDM 3 0.0111
(0.2027)
0.0056
(0.1014)
0.0037
(0.0676)
XLDM 4.5 0.0065
(0.1182)
0.0032
(0.0591)
0.0022
(0.0393)
XLDM 10 0.0044
(0.0795)
0.0022
(0.0397)
0.0015
(0.0265)
XLDM 20 0.0017
(0.0308)
0.0008
(0.0154)
0.0006
(0.0103)
XLDM 30 0.0023
(0.0427)
0.0012
(0.0213)
0.0008
(0.0142)
XLDM 70 0.0026
(0.0466)
0.0013
(0.0233)
0.0009
(0.0155)
 
3 Removal efficiencies based upon a modified ASTM F795 Dynamic Single Pass Efficiency test.
4 Pressure drop in psid per gpm for the cartridge length shown. M13:28:02ultiply this value by the total system flow to determine the aqueous pressure drop. Note, for fluids other than water, multiply this value by the fluids viscosity at the operating temperature in centipoise. This value is the pressure drop across the Marksman XLD High Flow filter(s) only; it must be added to the pressure drop due to the High Flow filter housing. For kPa/lpm, multiply mbard/lpm by 0.1000.


House Ratings

 
Vessel Material Tubesheet and Hold Down Plate
Material of Construction
Pressure Rating in Psig/Bar @
140°F / 60°C
Carbon steel 304 stainless steel 275 psig (19.0 bar)
304 stainless steel 304 stainless steel 259 psig (17.9 bar)
304L stainless steel 304L stainless steel 216 psig (14.9 bar)
316 stainless steel 316 stainless steel 261 psig (18.0 bar)
316L stainless steel 316L stainless steel 216 psig (14.9 bar)
 


Figure 1: High Flow Horizontal Housings (Aqueous Housing Pressure Drop - PSID)


Type

Large Format Filters

Ordering Information

XLDM ■ - ● U-HF ♦ (e.g., XLDM3-20U-HFJ)



 
Code
Filter Grades
1.5 1.5 μm
3 3 μm
4.5 4.5 μm
10 10 μm
20 20 μm
30 30 μm
70 70 μm
 


 
Code
Cartridge Lengths - nominal (inches/mm)
20 20/508
40 40/1016
60 60/1524
 


 
Code
Seal/O-ring Material
H13 Nitrile O-ring
H13U Nitrile U-cup
H Fluorocarbon Elastomer O-ring
HU Fluorocarbon Elastomer U-cup
J Ethylene Propylene O-ring
JU Ethylene Propylene U-cup
 


Ordering Information-Standard Horizontal and Vertical Housings



Ordering Information - Horizontal Orientation, Centerpipe Designed Housings



 
Code
Housing Configuration
H Horizontal
V Vertical
 


 
Code
Nominal Cartridge Length
(Inches/mm)
2 20/508
4 40/1016
6 60/1524
 


 
Code
Housing Metallurgy
285 Carbon Steel Vessel, 304 Stainless Steel Tubesheet
S3 304L Stainless Steel
S8 304 Stainless Steel
L3 316L Stainless Steel
L8 316 Stainless Steel
 


 
Code
Optional Outlet Size5
Horizontal Housings
XU Upper Outlet Location
XL Lower Outlet Location
 

5 If the housing is to be used as a prefiller to a horizontal liquid/liquid coalescer, then the vessel should be ordered using the XU or XL option for the outlet location. The orientation of the outlet should be the same as that of the sump on the coalescer. In this way no buildup of coalesced liquid will occur in the prefiller.

Reviews

We appreciate your review of this product. Please login to your account to leave a review.