Pall Advanta™ In-Line Liquid and Gas Filter Housings product photo Primary L

Pall Advanta™ In-Line Liquid and Gas Filter Housings

The Pall Advanta range of liquid and gas housings has been specifically designed and engineered for today’s manufacturing processes. This advanced liquid gas cartridge housing is manufactured from 316L stainless steel and is engineered to meet the requirements of the biopharmaceutical industry. State-of-the-art manufacturing technologies are used to construct a housing ideal for the most critical applications.

Fine filtration of liquids and gases is a key part of many production processes. The Pall Advanta housings have been specifically designed to meet the many requirements of these demanding applications. Optimization of critical features during the design process has provided a housing range that ensures trouble-free use and low installation and maintenance costs. Areas included in this process were:
  • Surface finish
  • Suitability for CIP and SIP
  • Integrity testing
  • Incorporation into automated production processes

Features of Liquid and Gas Filter Housings

  • Aseptic design
    • Crevice-free electropolished surfaces with an internal Ra value of < 0.4 µm (< 15 µin.)
    • Fully self-draining
    • No dead legs
  • Low hold-up volumes for maximum product recovery
  • Quick fit Stäubli1 type connections for easy filter integrity testing
  • Easy to use low point sanitary drain valve
  • Range of options to aid use in automated production systems
  • Every housing is supplied with a quality certificate and manufactured to ATEX Directive 94/9/EC (Group ll Category 2)
  • CE marked in accordance with Pressure Equipment Directive 97/23/EC

1Stäubli is a trademark of Stäubli AG.


Contact Us
* Required

Documents

Datasheets

Download: English

Description

The Pall Advanta range of liquid and gas housings has been specifically designed and engineered for today’s manufacturing processes. This advanced liquid gas cartridge housing is manufactured from 316L stainless steel and is engineered to meet the requirements of the biopharmaceutical industry. State-of-the-art manufacturing technologies are used to construct a housing ideal for the most critical applications.

Fine filtration of liquids and gases is a key part of many production processes. The Pall Advanta housings have been specifically designed to meet the many requirements of these demanding applications. Optimization of critical features during the design process has provided a housing range that ensures trouble-free use and low installation and maintenance costs. Areas included in this process were:
  • Surface finish
  • Suitability for CIP and SIP
  • Integrity testing
  • Incorporation into automated production processes

Features of Liquid and Gas Filter Housings

  • Aseptic design
    • Crevice-free electropolished surfaces with an internal Ra value of < 0.4 µm (< 15 µin.)
    • Fully self-draining
    • No dead legs
  • Low hold-up volumes for maximum product recovery
  • Quick fit Stäubli1 type connections for easy filter integrity testing
  • Easy to use low point sanitary drain valve
  • Range of options to aid use in automated production systems
  • Every housing is supplied with a quality certificate and manufactured to ATEX Directive 94/9/EC (Group ll Category 2)
  • CE marked in accordance with Pressure Equipment Directive 97/23/EC

1Stäubli is a trademark of Stäubli AG.

Specifications

Materials of Construction

  • Housing: AISI 316L stainless steel
  • Clamp: 431 Stainless Steel
  • Seals: Silicone elastomer
  • Surface Finish: All electropolished
       Internal: Ra < 0.4 µm (< 15 µin.) (typical)
       External: Ra < 0.8 µm (< 32 µin.) (typical)

Inspection Documentation

  • Certificate type 2.3 to EN10204

Operating Conditions

  • Maximum Operating Pressure: -1 to 10 barg (-14.52 to 1503 psig)
  • Maximum Operating Temperature:150 °C (300 °F)

Nominal Dimensions

Part Number Overall Height Clearance Required Weight
ALI105G23LABH4  301 mm (11.8 in.) 150 mm (5.9 in.) 2.2 kg (4.8 lbs)
ALI105G23LDDH4 301 mm (11.8 in.) 150 mm (5.9 in.) 2.2 kg (4.8 lbs)
ALI11G23LAAH4 437 mm (17.2 in.) 310 mm (12.2 in.) 2.6 kg (5.7 lbs)
ALI11G23LABH4 437 mm (17.2 in.) 310 mm (12.2 in.) 2.6 kg (5.7 lbs)
ALI11GA23LDDH4 437 mm (17.2 in.) 310 mm (12.2 in.) 2.6 kg (5.7 lbs)
ALI12G23LABH4 688 mm (27 in.) 564 mm (22.2 in.) 3.5 kg (7.7 lbs)
ALI12G23LDDH4 688 mm (27 in.) 564 mm (22.2 in.) 3.5 kg (7.7 lbs)
ALI13G23LABH4 961 mm (37.8 in.) 818 mm (32.2 in.) 4.3 kg (9.47 lbs)
ALI13G23LDDH4 961 mm (37.8 in.) 818 mm (32.2 in.) 4.3 kg (9.47 lbs)

Gas Filtration: This housing style is suitable for use in the filtration of gases. The inline design ensures that the pressure drops are exceptionally low. Pall recommends using the cartridge pressure drop when calculating the system pressure drops. Please refer to the relevant cartridge literature or contact Pall.

Typical Air Flow Rates4


Advanta In-Line Liquid and Gas Filter Housings Air Flow 

Typical Water Flow Rates4


Advanta In-Line Liquid and Gas Filter Housings Water Flow 

2Full vacuum.
3With compatible fluids, which do not soften, swell or adversely affect the gasket materials.
4The flow and pressure drop characteristics refer to the empty housing only for water at 20 °C (68 °F). For other liquids multiply pressure drop by relative density. To obtain the total pressure drop of a complete filter assembly, the cartridge pressure drop must be added.

Type

Housings, Vessels, or Assemblies

Ordering Information

This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please contact Pall.

Example Part Number: ALT D 1 294 A B H45 (See bold references in tables below)

Part Number: ALT < Design Code from Table 1 > 1 < Cartridge Code from Table 2 > G < Inlet/Outlet Code from Table 3 > < Vent Code from Table 4 > < Drain Code from Table 5 > H4

Table 1 - Design

Code Design
- To European Pressure Equipment Directive
D To European Pressure Equipment Directive with enhanced documentation including 3.1b stamped material and certification

Table 2 - Cartridge Type

Code Cartridge Type
05 AB05 code 2
1 AB1 code 7
2 AB2 code 7
3 AB3 code 7

Table 3 - Inlet/Outlet

Code Inlet and Outlet
23L 1 1/2 in. sanitary flange to ISO 2037/BS 4825
94 33.7 mm (1.33 in.) O.D x 2.0 mm (0.079 in.) wall butt weld to ISO 1127

Table 4 - Vent

Code Vent
A Sanitary valve fitting for Stäubli type couplings
D 1⁄2 in. sanitary flange to ISO 2037/BS 4825

Table 5 - Drain

Code Drain
A Sanitary valve coupling to Stäubli type RBE.03
B Sanitary valve with hosetail for 6 mm (1⁄4 in.) ID tubing
D 1⁄2 in. sanitary flange connection to to ISO 2037/BS 4825

5Gasket material — silicone, other gasket materials available on request. Please contact Pall.

Reviews