GeneDisc® Plates for Listeria Detection product photo Primary L

GeneDisc® Plates for Listeria Detection

Listeria monocytogenes is an opportunistic foodborne pathogen that can affect a wide range of food products and can cause severe infections with high mortality rate to the elderly, immunodepressed persons and pregnant women. Since L. monocytogenes has the ability to grow slowly at refrigerated temperatures, it is a major concern for food companies.

Two factors have also raised interest for Listeria spp. detection. Cases of listeriosis related to other Listeria spp. have been reported. Furthermore, evidence suggests the presence of other non-pathogenic Listeria spp. can be an early indication of L. monocytogenes contamination.

Pall GeneDisc Technologies provides solutions for food processors in need of a reliable control of L. monocytogenes and/or Listeria spp. risk.

GeneDisc System Benefits

Rapid — Accelerate your controls workflow and achieve fast releases of short shelf life products and testing of raw materials. While other methods such as immunoassays or culture methods (chromogenic media) require up to 3 days to get a result, Pall's GeneDisc method allows a detection of Listeria in as fast as 20 hours.

Easy to use — GeneDisc solutions are designed for routine use. Implementing PCR (Polymerase Chain Reaction) has never been this easy.

Modular — System modularity fits your throughput needs: up to 96 samples can be analyzed in a one hour PCR run.

A Solution Designed For Food Industries

In line with MLG 8, BAM 10, OMA 993.12 and ISO 11290 – NF VALIDATION and AOAC certified method.

Adaptive to testing needs – Simultaneous or individual testing solutions for L. monocytogenes and Listeria spp. are available with same hands-on time and enrichment.

Listeria monocytogenes Identification

 
Bacteria Gram + bacilli
Food Vehicle Large variety of food especially dairy, raw meat and ready-to-eat products
Disease Listeriosis – can cause severe, invasive infections (e.g., sepsis, meningitis, fetal death)
Incidence of Cases (per 100,000 population) 0.28 (FoodNet, 2010)
Notification Rate (per 100,000 population) 0.35 (EFSA, ECDC, 2010)
Related Outbreaks 3 (strong evidence) (EFSA, ECDC, 2010)
7 (CDC, 2010)
Related Recalls 102 (FDA & FSIS, 2012)
Related Alerts / Information 106 (RASFF, 2011)
 

How the System Works



Validations

 
Validation Matrix Time to Result
AOAC Variety of foods and selected environmental surfaces 26 h
NF VALIDATION Food products and environmental samples 26 h
Raw milk 20 h
 


Need Help?
Ask a Question
* Required

Order Products

GeneDisc® Listeria, GLISMON206006

Product ID: GLISMON206006
Unit of Measure
1/EA
Min Order Qty
1
Number of Samples per GeneDisc Plate
6
Number of Samples per Kit
36

GeneDisc® Listeria, GLISMON212006

Product ID: GLISMON212006
Unit of Measure
1/EA
Min Order Qty
1
Number of Samples per GeneDisc Plate
12
Number of Samples per Kit
72

GeneDisc® Listeria, GLISSPP106006

Product ID: GLISSPP106006
Unit of Measure
1/PAC
Min Order Qty
1
Number of Samples per GeneDisc Plate
6
Number of Samples per Kit
36

GeneDisc® Listeria, GLISSPP112006

Product ID: GLISSPP112006
Unit of Measure
1/PAC
Min Order Qty
1
Number of Samples per GeneDisc Plate
12
Number of Samples per Kit
72

Documents

Datasheets

Download: English

Description

Listeria monocytogenes is an opportunistic foodborne pathogen that can affect a wide range of food products and can cause severe infections with high mortality rate to the elderly, immunodepressed persons and pregnant women. Since L. monocytogenes has the ability to grow slowly at refrigerated temperatures, it is a major concern for food companies.

Two factors have also raised interest for Listeria spp. detection. Cases of listeriosis related to other Listeria spp. have been reported. Furthermore, evidence suggests the presence of other non-pathogenic Listeria spp. can be an early indication of L. monocytogenes contamination.

Pall GeneDisc Technologies provides solutions for food processors in need of a reliable control of L. monocytogenes and/or Listeria spp. risk.

GeneDisc System Benefits

Rapid — Accelerate your controls workflow and achieve fast releases of short shelf life products and testing of raw materials. While other methods such as immunoassays or culture methods (chromogenic media) require up to 3 days to get a result, Pall's GeneDisc method allows a detection of Listeria in as fast as 20 hours.

Easy to use — GeneDisc solutions are designed for routine use. Implementing PCR (Polymerase Chain Reaction) has never been this easy.

Modular — System modularity fits your throughput needs: up to 96 samples can be analyzed in a one hour PCR run.

A Solution Designed For Food Industries

In line with MLG 8, BAM 10, OMA 993.12 and ISO 11290 – NF VALIDATION and AOAC certified method.

Adaptive to testing needs – Simultaneous or individual testing solutions for L. monocytogenes and Listeria spp. are available with same hands-on time and enrichment.

Listeria monocytogenes Identification

 
Bacteria Gram + bacilli
Food Vehicle Large variety of food especially dairy, raw meat and ready-to-eat products
Disease Listeriosis – can cause severe, invasive infections (e.g., sepsis, meningitis, fetal death)
Incidence of Cases (per 100,000 population) 0.28 (FoodNet, 2010)
Notification Rate (per 100,000 population) 0.35 (EFSA, ECDC, 2010)
Related Outbreaks 3 (strong evidence) (EFSA, ECDC, 2010)
7 (CDC, 2010)
Related Recalls 102 (FDA & FSIS, 2012)
Related Alerts / Information 106 (RASFF, 2011)
 

How the System Works



Validations

 
Validation Matrix Time to Result
AOAC Variety of foods and selected environmental surfaces 26 h
NF VALIDATION Food products and environmental samples 26 h
Raw milk 20 h
 

Specifications

 
Enrichment Time Down to 18 hours
Sample Preparation Time ‹ 1 hour for 48 samples
PCR Cycle Time ‹ 1 hour
Total Turnaround Time Down to 20 hours
Hands On Time About 45 minutes for 48 samples (‹1 min/sample)
Limit Of Detection 1 bacteria in 25 g of food sample and in environmental samples.
Specificity Wide range of strains tested for inclusivity and exclusivity
Internal Positive Control Per Sample Analysis Detects presence of inhibitors in DNA extract sample
 

Type

GeneDisc

Use

Diagnostics, Monitoring, Testing

Ordering Information

 
Part Number Description Samples/pack
Equipment
EGDUL1A230 (EU)
EGDUL1A120 (US)
GeneDisc Ultra-Lyser -
EGDCV3A GeneDisc Cycler Base Unit -
EGDSV3A GeneDisc Cycler Sub Unit -
Consumables
PFOOD1100 Extraction Pack Food 1 100
GLISMON206006
GLISMON212006
GeneDisc Listeria monocytogenes 36
72
GLISSPP106006
GLISSPP11200
GeneDisc Listeria spp. 36
72
GLISDUO106006
GLISDUO112006
GeneDisc Listeria DUO
(Listeria monocytogenes and Listeria spp.)
36
72
 

We also offer a full product range for pathogen detection in food and water and for spoilage organisms in beverage.

Quantitative tests for pathogens in water (Legionella, E. coli, Enterococcus…) are also available.

For more information including part numbers please contact us.