9900/01 Series Filter Assemblies product photo Primary L

9900/01 Series Filter Assemblies

Features

  • Flows to 910 L/min (250 US gpm)
  • Pressures to 420 bard (6100 psid)
  • Port size 2"
  • Ultipor® III filter medium pack
  • Out-to-in filter element flow path
Please Note:
The 9900/01/04 Series is a Preferred Product Line utilizing Ultipor® III filter medium. The 9900 and 9904 Series are no longer available as standard products. See Ordering Information for the list of available 9901 Series housing part numbers.

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.


Contact Us
* Required

Description

Features

  • Flows to 910 L/min (250 US gpm)
  • Pressures to 420 bard (6100 psid)
  • Port size 2"
  • Ultipor® III filter medium pack
  • Out-to-in filter element flow path
Please Note:
The 9900/01/04 Series is a Preferred Product Line utilizing Ultipor® III filter medium. The 9900 and 9904 Series are no longer available as standard products. See Ordering Information for the list of available 9901 Series housing part numbers.

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.

Specifications

Maximum Acceptable Working Pressure:

6000 psi (414 bar)

Fatigue Pressure Rating:

(NFPA/T2.6.1-1974 category 2/90)
3000 psi (207 bar)

Typical Burst Pressure:

15,000 psi (1035 bar)

Temperature Range:

Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

X length– 134 lbs. (61.1 kg)

Filter Element Collapse Pressure:

9400– 290 psid (20 bar)
9901– 3000 psid (207 bar)
9404– 150 psid (10 bar)

Dimensional Drawings

Performance

 

Element Pressure Drop Factor

Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

 
9400 Series Element P factor (psid/gpm)
 
Length
CZ
CP
CN
CS
CT
           
39"
0.06
0.03
0.02
0.02
0.01
 

 

 
9901 Series Element P factor (psid/gpm)
 
Length
CP
CT
     
26"
0.10
0.03
     
39"
0.06
0.02
 

Type

Housings, Vessels, or Assemblies

Ordering Information

Please select only from the following list of standard filter housing options.

Available 9900/9901 Series Options

 
HZ9900D32 XB1
HZ9900E32 XB1
HZ9900F32 XB1
HZ9900G32 XB1
HZ9900G32 XC1
HZ9901E32 XW1
HZ9901E32 VW1
HZ9901G32 XW1
HZ9901G32 VW1
 


The breakdown of filter housing, replacement element and seal kit part numbers is outlined in the tables below. However, housings are only available in the part numbers listed above.

Assembly P/N:     

H

990

Note: For heavy duty valve (B,C,or K option) add Y128 to end of part number

 

 

Table1

 

Table2
Table3
Table4
Table5
Table6
Table7
Table8


Element P/N:       

HC

F

 

 

 

 

 

 

Table2
 
Table5
Table6
Table1
 

 

 

 



TABLE 1: SEAL OPTIONS
 
Code
Seals
   
H
Nitrile
   
Z
Fluorocarbon
 

 

TABLE 2: ELEMENT OPTIONS
 
Code
Element Code
Rating
     
0
9400
290 psid (standard)
     
1
9901
3000 psid (high collapse)
 

 

TABLE 3: PORT STYLE OPTIONS
 
Code
Port Style
   
D
Flange SAE J518c-Code 61
   
E
Flange SAE J518c-Code 62
   
F
ISO 6162 Split Flange (3000 psi)
   
G
ISO 6162 Split Flange (6000 psi)
 

 

TABLE 4: PORT SIZE OPTIONS
 
Code
Size
   
32
2"
 

 

TABLE 5: FILTER ELEMENT OPTIONS
 
Code
ßx  200
ßx(c)=1000
     
CZ
<1
2.5
     
CP
3
5
     
CN
6
7
     
CS
12
12
     
CT
25
22
     
CP*
3
5
     
CT*
17
15
 
*9901 only.

 

TABLE 6: LENGTH OPTIONS*
 
Assembly Code
Element Code**
   
N/A
13
   
V
26
   

X

39

 
* Use code in second column for element part no.
** Nominal length in inches.

 

TABLE 7: BYPASS VALVE OPTIONS
 
Code
Description
   
B
50 psid- 9900/04 only
   
C
50 psid bypass with Reverse Flow-9900/04 only
   

W

Non-bypass-9901 only
 
Valve option W requires use of 3000 psid collapse element (series code ending in 'l').

 

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Differential Pressure Indicator P/N: RC [Table 8A]  Z 091 Z [Table 8B]

Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
TABLE 8A: Indicator Options
For applications with operating conditions less than 200 bar (3000 psi)
 

Code

Brass Option indicator

   

A218M

Electrical switch (SPDT) with Hirschmann connector
   

A218R

Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators
   

A219D

Visual indicator
 

For applications with operating conditions greater than 200 bar (3000 psi)
 

Code

Stainless Steel indicator

   

778NZ

Visual filter with thermal lockout
   

861CZ

Electrical Switch (SPDT) with 6" leads
   

861CZ*

Electrical switch (SPDT) with Hirschmann connector
   

771BZ

Electrical switch (SPDT) with 3-pin
 
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 8B.
TABLE 8B: Differential Pressure Indicator Material
 

Code

Pressure Setting

   

Omit

Brass Indicator: use at operating pressures < 200 bar (3000 psi)
   

SS

Stainless Steel Indicator: recommended for high pressure cycle applications with pressures > 200 bar (3000 psi)
 
Other setting options are available; contact Pall.

Reviews