UH319X128 Series Athalon® High Pressure Filters product photo Primary L

UH319X128 Series Athalon® High Pressure Filters

Athalon® maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity. Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today. (* per ISO 16889)

  • Flows to 600 L/min (160 US gpm)
  • Pressures to 420 bar (6100 psi)
  • Port size 114", 112" and 2"


Contact Us
* Required

Description

Athalon® maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity. Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today. (* per ISO 16889)

  • Flows to 600 L/min (160 US gpm)
  • Pressures to 420 bar (6100 psi)
  • Port size 114", 112" and 2"

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    420 bar (6100 psi)
  • Rated Fatigue Pressure:
  • 0-240 bar (3500 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million cycles), verified by testing at 0-280 bar (4050 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles
  • Typical Burst Pressure:
    1500 bar (21760 psi)
  • Temperature Range:
    Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids. Consult sales for other fluid group suitability
  • Bypass Valve Setting:
    4.5 bard (65 psid)
  • Indicator Pressure Setting:
    3.5 bard (50 psid)
  • Materials of Construction:
    Head and cover: Ductile cast iron
    Tube: Carbon steel

Filter Element

  • Filter Element Burst Pressure:
    10 bard (150 psid)
  • Athalon™ Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design.
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.

 Specifications

 
Length
Code
'C' Option
Overall
Length
mm (in.)
‘H’ Option
Overall Length
mm (in)
'C' Option
Element
Removal
Clearance
mm (in.)
‘H’ Option
Element Removal
Clearance mm (in)
Empty
Weight
kg (lb)
08 454 (17.9) 467 (18.4) 205 (8.07) 138 (5.43) 38.6 (85)
13 589 (23.2) 602 (23.7) 340 (13.39) 138 (5.43) 43.6 (96.1)
20 759 (29.9) 772 (30.4) 510 (20.08) 138 (5.43) 49.9 (110)
40 1267 (49.9) 1280 (50.4) 1020 (40.16) 138 (5.43) 68.7 (151.4)
 

UH319X128 Housing









Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

319 Series Filter Elements — bard/1000 L/min (psid/US gpm)

 
Length Code AZ AP AN AS AT
08 5.52 (0.302) 2.30 (0.126) 1.82 (0.100) 1.32 (0.072) 0.82 (0.045)
13 3.31 (0.182) 1.38 (0.076) 1.09 (0.060) 0.79 (0.043) 0.49 (0.027)
20 2.18 (0.120) 0.91 (0.050) 0.72 (0.040) 0.52 (0.029) 0.33 (0.018)
40 1.10 (0.060) 0.46 (0.025) 0.36 (0.020) 0.26 (0.014) 0.16 (0.009)
 

Sample ΔP calculation

UH319 Series 13" length housing with G24 (1 1/2"SAE) split flange ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.34 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.45 (housing) + 0.68 bard (element)
= 1.13 bard (16.4 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

For new installations, select one complete part number from each section below

Section 1

Housing P/N:

Note: Pall filter housings are supplied without filter elements or filter change out warning devices. Never operate the filter housing unless a filter element is fitted and all warning device ports are sealed.

Housing part number designates indicator port is fitted with a plastic shipping plug.

 
Part Number Part Number
UH319CA2008ZG9X128 UH319CE2013ZG9X128
UH319CA2013ZG9X128 UH319CE2408ZG9X128
UH319CA2408ZG9X128 UH319CE2413ZG9X128
UH319CA2413ZG9X128 UH319CE2420ZG9X128
UH319CA2420ZG9X128 UH319CE3213ZG9X128
UH319CA3213ZG9X128 UH319CE3220ZG9X128
UH319CA3220ZG9X128 UH319CE3240ZG9X128
UH319CC2008ZG9X128 UH319CG2008ZG9X128
UH319CC2013ZG9X128 UH319CG2013ZG9X128
UH319CC2408ZG9X128 UH319CG2408ZG9X128
UH319CC2413ZG9X128 UH319CG2413ZG9X128
UH319CC2420ZG9X128 UH319CG2420ZG9X128
UH319CC3213ZG9X128 UH319CG3213ZG9X128
UH319CC3220ZG9X128 UH319CG3220ZG9X128
UH319CE2008ZG9X128 UH319CG3240ZG9X128
 

 
Part Number (Description) Breakdown
UH319C = UH319 series housing cover service
A20, A24, A32 = 1¼”, 1½”, 2” SAE J514 straight thread ports
C20, C24, C32 = 1¼”, 1½”, 2” BSP ISO228 thread ports
E20, E24, E32 = 1¼”, 1½”, 2” Flange J518C code 62 ports
G20, G24, G32 = 1¼”, 1½”, 2” ISO 6162 split flange ports
(400 bar/5800 psi max pressure)
08 = 8 inch nominal length
13 = 13 inch nominal length
20 = 20 inch nominal length
40 = 40 inch nominal length
Z = Fluorocarbon seals
G = 4.5 bard (65 psid) bypass valve
9 = 2 indicator warning device ports
X128 = High fatigue design
 

Section 2

Element P/N: UE 310 [Table 1] [Table 2] Z                                                  

Table 1: Filter Element Options

 
Code ßx(c) ≥1000
based on ISO 16889
CST Rating*
AZ 3 07/04/01
AP 5 11/08/03
AN 7 13/09/04
AS 12 15/11/06
AT 25 16/14/08
 


Table 2: Filter Element Length Options

 
Code Length (in.)*
08 8 inch nominal length 
13 13 inch nominal length 
20 20 inch nominal length 
40 40 inch nominal length 
 
* Nominal length

Section 3 

Differential Pressure Indicator P/N: RC [Table 3]  Z [Table 4] Z [Table 5]

Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 3: Indicator Options

For applications with operating conditions less than 200 bar (3000 psi)

 
Code Brass Option indicator
A218M Electrical switch (SPDT) with Hirschmann connector
A218R Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators
A219D Visual indicator
 

 
Code Stainless Steel Option indicator
778N Visual filter with thermal lockout
861C Electrical switch (SPDT) with Hirschmann connector
771B Electrical switch (SPDT) with 3-pin
 


Table 4: Indicator Pressure Setting Option

 
Code Description
084 For A valve option housings (1.1. bard. 16 psid)
091 For G valve option housings (3.5. bard. 50 psid)
 


Table 5: Differential Pressure Indicator Material

 
Code Pressure Setting
Omit Brass Indicator: use at operating pressures < 200 bar (3000 psi)
SS Stainless Steel Indicator: recommended for high pressure cycle applications with pressures > 200 bar (3000 psi)
 

Reviews