F410 Series Versalon® Medium Pressure Filters product photo Primary L

F410 Series Versalon® Medium Pressure Filters

Features

  • Flows to 250 L/min (66 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 114 in. and 112 in.
  • Out-to-in filter element flow path


Contact Us
* Required

Documents

Datasheets

Download: English

Description

Features

  • Flows to 250 L/min (66 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 114 in. and 112 in.
  • Out-to-in filter element flow path

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    70 bar (1015 psi)
  • Rated Fatigue Pressure:
    0 - 40 bar (580 psi) per NFPA T2.6.1 R2-2001 CAT C/90, verified by testing at 0 - 46.5 bar (675 psi)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals:
    -29 ?C to 120 ?C (-20 ?F to 250 ?F)
    50 ºC (122 ºF) maximum in HWCF or water glycol fluids
  • Bypass Valve Settings:
    ‘G’ option – 4.5±0.5 bard (50±7 psid)
  • Indicator Pressure Settings:
    3.4±0.5 bard (50±7 psid) for ‘G’option
  • Materials of Construction:
    Head: SG Iron
    Bowl: Aluminium

Filter Element

  • Filter Element Collapse Pressure:
    10 bard (145 psid)
  • Filter Element Construction:
    Inorganic fibers impregnated and bonded with specifically formulated resins. Polyamide endcaps. Corrosion protected carbon steel core.

Dimensional Drawings

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.



HCG300 Filter Elements – bard/1000 L/min (psid/US gpm

 
Length Code KN KS KD KT
10 2.20 (0.12) 1.47 (0.08) 1.13 (0.06) 1.01 (0.05)
13 1.69 (0.09) 1.11 (0.06) 0.85 (0.05) 0.77 (0.04)
 


Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

Sample ΔP calculation

F410 Series 10 in. length housing with C20 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 20 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.21 x 1.2/0.9) bard (housing)
   + ((100 x 2.2/1000) x 20/32 x 1.2/0.9) bard (element)
= 0.28 bard (housing) + 0.18 bard (element)
= 0.46 bard (6.67 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

 
Part Number Description
HZF410C20CSKG00001 HZF410C20CSKG11X160
HZF410C24CSTG00001 HZF410C24CSTG11X160
HZF410A20CSKG00001 HZF410A20CSKG11X160
HZF410A24CSTG00001 HZF410A24CSTG11X160
 
* Other options available, contact factory
Element P/N: HCG300F [Table 2] [Table 3] Z

Seal P/N: G300SKZ

Table 1: Housing Port & Size Options

 
Code Port Size Port Style Option
A20 1 14 in. SAE J1926 straight thread
A24 1 12 in.
C20 1 14 in. BSP Thread to ISO 228
C24 1 12 in.
 

Table 2: Filter Element Options

 
Code ßx(c) ≥1000 based on ISO 16889
CN 7
CS 12
KD 19
CT 22
 

Table 3: Length Options

 
Housing Code Element Code Length (in)*
K 10 271 mm (10.67 in.)
T 13 339 mm (13.35 in.)
 
* Nominal length

Table 4: Differential Pressure Indicator Options

 
Code Indicator
1 Machined port with plastic shipping plug
Indicator must be installed prior to operation
 

Reviews

We appreciate your review of this product. Please login to your account to leave a review.