UR319 Series Ultipleat® SRT Return Line Filters product photo Primary L

UR319 Series Ultipleat® SRT Return Line Filters

Features

  • Flows to 760 L/min (200 US gpm)
  • Pressures to 41 bard (600 psid)
  • Port size 112", 2" and 212"
  • Unique Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UR319 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.


Contact Us
* Required

Description

Features

  • Flows to 760 L/min (200 US gpm)
  • Pressures to 41 bard (600 psid)
  • Port size 112", 2" and 212"
  • Unique Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UR319 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    41 bard (600 psid)
  • Rated Fatigue Pressure:
    41 bard (600 psid) 106 cycles per NFPA T2.06.01R2-2001
  • Typical Burst Pressure:
    145 bard (2100 psid)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids
  • Materials of Construction:
    Tube: Carbon steel
    Head and Cover: Ductile Cast Iron

Filter Element

  • Filter Element Burst Pressure:
    10 bard (150 psid)
  • Ultipleat SRT Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.

'C' Housings with 'G' option valve

 
Length
Code
'C' Option
Overall
Length
mm (in.)
'C' Option Element
Removal
Clearance
mm (in.)
Empty
Weight
kg (lb)
08 424 (16.69) 230 (9) 18 (40)
13 559 (21.99) 370 (14.5) 21 (46)
20 729 (28.69) 530 (21) 23 (51)
40 1237 (48.69) 1040 (41) 30 (66)
 

'C' Housings with 'C' option valve

 
Length
Code
'C' Option
Overall
Length
mm (in.)
'C' Option Element
Removal
Clearance
mm (in.)
Empty
Weight
kg (lb)
08 511 (20.13) 230 (9) 20 (45)
13 646 (25.43) 370 (14.5) 23 (51)
20 816 (32.13) 530 (21) 25 (56)
40 1324 (52.13) 1040 (41) 32 (71)
 






Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

319 Series Filter Elements — bard/1000 L/min (psid/US gpm)

 
Length Code AZ AP AN AS AT
08 5.52 (0.302) 2.30 (0.126) 1.82 (0.100) 1.32 (0.072) 0.82 (0.045)
13 3.31 (0.182) 1.38 (0.076) 1.09 (0.060) 0.79 (0.043) 0.49 (0.027)
20 2.18 (0.120) 0.91 (0.050) 0.72 (0.040) 0.52 (0.029) 0.33 (0.018)
40 1.10 (0.060) 0.46 (0.025) 0.36 (0.020) 0.26 (0.014) 0.16 (0.009)
 

Sample ΔP calculation

UR3 19 Series 20" length housing with F24 (11⁄2" SAE) split flange ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.48 x 1.2/0.9) bard (housing)
+ ((300 x 0.72/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.64 bard (housing) + 0.45 bard (element)
= 1.09 bard (15.8 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

Please select only from the following list of standard filter housing options.

Available UR319 Series Options

 
UR319CA24 08ZA9YR85
UR319CC24 08ZA9YR85
UR319CA24 13ZA9YR85
UR319CC24 13ZA9YR85
UR319CA24 20ZA9YR85
UR319CC24 20ZA9YR85
UR319CA24 40ZA9YR85
UR319CC24 40ZA9YR85
UR319CA32 13ZA9YR85
UR319CC32 13ZA9YR85
UR319CD32 13ZA9YR85
UR319CF32 13ZA9YR85
UR319CA32 20ZA9YR85
UR319CC32 20ZA9YR85
UR319CD32 20ZA9YR85
UR319CF32 20ZA9YR85
UR319CA32 40ZA9YR85
UR319CC32 40ZA9YR85
UR319CD32 40ZA9YR85
UR319CF32 40ZA9YR85
UR319CD40 13ZA9YR85
UR319CF40 13ZA9YR85
UR319CD40 20ZA9YR85
UR319CF40 20ZA9YR85
UR319CD40 40ZA9YR85
UR319CF40 40ZA9YR85
UR319CA24 08ZG9YR85
UR319CC24 08ZG9YR85
UR319CA24 13ZG9YR85
UR319CC24 13ZG9YR85
UR319CA24 20ZG9YR85
UR319CC24 20ZG9YR85
UR319CA24 40ZG9YR85
UR319CC24 40ZG9YR85
UR319CA32 13ZG9YR85
UR319CC32 13ZG9YR85
UR319CD32 13ZG9YR85
UR319CF32 13ZG9YR85
UR319CA32 20ZG9YR85
UR319CC32 20ZG9YR85
UR319CD32 20ZG9YR85
UR319CF32 20ZG9YR85
UR319CA32 40ZG9YR85
UR319CC32 40ZG9YR85
UR319CD32 40ZG9YR85
UR319CF32 40ZG9YR85
UR319CD40 13ZG9YR85
UR319CF40 13ZG9YR85
UR319CD40 20ZG9YR85
UR319CF40 20ZG9YR85
UR319CD40 40ZG9YR85
UR319CF40 40ZG9YR85
UR319CA24 08ZN9YR85
UR319CC24 08ZN9YR85
UR319CA24 13ZN9YR85
UR319CC24 13ZN9YR85
UR319CA24 20ZN9YR85
UR319CC24 20ZN9YR85
UR319CA24 40ZN9YR85
UR319CC24 40ZN9YR85
UR319CA32 13ZN9YR85
UR319CC32 13ZN9YR85
UR319CD32 13ZN9YR85
UR319CF32 13ZN9YR85
UR319CA32 20ZN9YR85
UR319CC32 20ZN9YR85
UR319CD32 20ZN9YR85
UR319CF32 20ZN9YR85
UR319CA32 40ZN9YR85
UR319CC32 40ZN9YR85
UR319CD32 40ZN9YR85
UR319CF32 40ZN9YR85
UR319CD40 13ZN9YR85
UR319CF40 13ZN9YR85
UR319CD40 20ZN9YR85
UR319CF40 20ZN9YR85
UR319CD40 40ZN9YR85
UR319CF40 40ZN9YR85
 

The specification of each filter housing part number is outlined in the tables below.

Section 1

Housing P/N: UR 319 [Table 1] [Table 2] ++ [Table 3] Z [Table 4] 9 YR85

Seal Kit P/N: UR 319 SKZ
Note: Pall Ultipleat SRT filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The suffix ‘9’ at the end of the Housing P/N designates 2 indicator ports, one fitted with a plastic shipping plug and the other with a bleed plug.

Table 1: Housing Orientation Options

 
Code Port
C Cap service (tube up)
 

Table 2: Housing Port Options

 
Code Port
A24 1½" SAE J514 straight thread
A32 2" SAE J514 straight thread
C24 1½" BSP ISO 228 threads
C32 2" BSP ISO 228 threads
D32 2" Flange J518C code 61 with ½"-13 UNC holding bolts
D40 2½" Flange J518C code 61 with ½"-13 UNC holding bolts
F32 2" ISO 6162 split flange with M12 x 1.75 holding bolts
F40 2½" ISO 6162 split flange with M12 x 1.75 holding bolts
 

Table 3: Housing Length Options

 
Code Length (in)*
08 8
13 13
20 20
40 40
 
* Nominal length

Table 4: Housing Bypass Valve Options

 
Code Valve
A 1.7 bard - 25 psid
Use 084 code indicator only
C 4.5 bard - 65 psid bypass valve with resevse flow
Use 091 code indicator only
N Non-Bypass
Use 091 code indicator only
 

Section 2

Element P/N: UE 319 [Table 1] [Table 2] Z
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 1: Filter Element Options

 
Code ßx(c) ≥1000
based on ISO 16889
CST Rating*
AZ 3 08/04/01
AP 5 12/07/02
AN 7 15/11/04
AS 12 16/13/04
AT 22 17/15/08
 
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205

Table 2: Filter Element Length Options

 
Code Length (in.)*
08 8
13 13
20 20
40 40
 
* Nominal length

Section 3 (At least one Differential Pressure Indicator or ‘B’ type blanking plug must be ordered)

Differential Pressure Indicator P/N: RC [Table 1] [Table 2] Z [Table 3] [Table 4]

Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 1: Differential Pressure Indicator Options*

 
Code Indicator ‘H’ Dim.
778NZ ‘P’ type Visual indicator with thermal lockout 21mm (0.83in)
860MZ ‘D’ type Visual indicator with no thermal lockout 21mm (0.83in)
861CZ ‘L’ type Electrical switch (SPDT) with 6" leads 38mm (1.50in)
861CZ ‘M’ type Electrical switch (SPDT) with DIN43650 connector and matching cap 78mm (3.07in)
861CZ ‘R’ type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap 89mm (3.50in)
771BZ ‘S’ type Electrical switch (SPDT) with 3-pin MS connector 57mm (2.24in)
 
* Other options available on application.

Table 2: Indicator Pressure Setting Option*

 
Code Valve
084 For ‘A’ Valve Option - Housings (1.1 bard - 16 psid)
091 For ‘C’, ‘G’ and ‘N’ Valve Options - Housings (3.5 bard - 50 psid)
 
* Other setting options are available; contact Pall.

Table 3: ‘M’ & ‘R’-Type Indicator Codes*

 
Code Option
YM ‘M’ option
YR ‘R’ option
 
* Use only if ‘R’ or ‘M’ Indicator is selected from Table 1

Table 4: ‘R’ Indicator Options

 
Code Option
110AC 110V AC
220AC 220V AC
24DC 24V DC
 
* Use only if ‘R’Indicator is selected from Table 1

Reviews

We appreciate your review of this product. Please login to your account to leave a review.