F410 Series 'T' Filters product photo Primary L

F410 Series 'T' Filters

Features

  • Out-to-in filter element flow path
  • Flows to 250 L/min (66 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 11?4 in. and 11?2 in.


Contact Us
* Required

Documents

Datasheets

Download: English

Description

Features

  • Out-to-in filter element flow path
  • Flows to 250 L/min (66 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 11?4 in. and 11?2 in.

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    70 bar (1015 psi)
  • Rated Fatigue Pressure:
    0 - 40 bar (580 psi) per NFPA T2.6.1 R2-2001 CAT C/90, verified by testing at 0 - 46.5 bar (675 psi)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    • Nitrile Seals: -43 ?C to 120 ?C (-46 ?F to 250 ?F)
    • Fluorocarbon Seals: -29 ?C to 120 ?C (-20 ?F to 250 ?F) 60 ®C (140 ®F) maximum in HWCF or water glycol fluids
  • Bypass Valve Settings:
    • 'B' option ® 3.4 bard (50 psid)
    • 'G' option ® 4.5 bard (65 psid)
  • Indicator Pressure Settings:
    • 2.4 bard (35 psid) for 'B'option
    • 3.4 bard (50 psid) for 'G'option
  • Materials of Construction:
    • Head: SG Iron
    • Bowl: Aluminium steel

Filter Element

  • Filter Element Collapse Pressure: 10 bard (145 psid)
  • Filter Element Construction: Pall Ultipor® filter medium, a propreitary composite structure with a fixed graded pore construction of inert, inorganic fibres impregnated and bonded with specifically formulated resins. Polyamide endcaps. Corrosion protected carbon steel core.

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.



HCG300 Filter Elements ® bard/1000 L/min (psid/US gpm)

Length Code KN KS KD KT
10 2.2 (0.12) 1.47 (0.08) 1.13 (0.06) 1.01 (0.05)
13 1.69 (0.09) 1.11 (0.06) 0.85 (0.05) 0.77 (0.04)

Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

Sample ?P calculation

F410 Series 10 in. length housing with C20 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 20 cSt and specific gravity (s.g.) 1.2.

Total Filter ?P
  • ?P housing + ?P element
  • (0.25 x 1.2/0.9) bard (housing)
    • ((100 x 2.2/1000) x 20/32 x 1.2/0.9) bard (element)
  • 0.33 bard (housing) + 0.18 bard (element)
  • 0.51 bard (7.44 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

Housing P/N: H [1] F410 [2] [3] [4] [5] [6] [7] X160
Element P/N: HCG300F [3] [4] [1]
Seal P/N: G400SK [1]

Table 1: Seal Options

Code Fluid Service Seal Material
H Petroleum, Water-Oil Emulsions, Water glycol Nitrile
Z Specified Synthetics Fluorocarbon

Table 2: Housing Port & Size Options

Style Code Size Code Port Size Port Style Option
A 20 1 1?4 in. O-Ring boss per SAE J1926
24 1 1?2 in.
C 20 1 in. BSP Thread to ISO 228
24 1 1?2 in.

Table 3: Filter Element Options

Code ®x(c) ?1000
KN 7
KS 12
KD 19
KT 22
++ No Element

Table 4: Length Options

Housing Code Element Code Length L*
K 10 271 mm ( 10.7 in. )
T 13 339 mm ( 13.35 in. )
* Nominal length


Table 5: Valve Options

Code Option
B 3.4 ®0.3 bar (50 psid)
G 4.5 ®0.5 bar (65 psid)

Table 6: Differential Pressure Indicator Options

Code Indicator 'H' Dim.
1 Machined port with plastic shipping plug
Indicator must be installed prior to operation
Only available to distributors
-
B Bleed plug and seal in place of indicator 16
D Visual indicator, red button rises 5mm on actuation
Remains up until manually reset
23
C Electrical switch - normally closed, automatic reset
Connection: deutsch DT042P
Reed switch operation suitable for low current applications
56
P Visual indicator with thermal lockout and manual reset
No signal below 0 ®C , signal above 27 ®C
Indicator includes clear plastic cover and internal dirt protection
23
R Electrical switch-SPDT with neon light indicator
Connection: plug and socket as per DIN43650,
ISO 4400, Hirschmann type (24 volt DC)
90
U Electrical switch - normally closed, automatic reset
Connection: AMP junior timer connector
Reed switch operation suitable for low current applications
47

Table 7: Drain Options

Code Option
0 None
3 1?4 BSP
6 1?4 BSP

Reviews

We appreciate your review of this product. Please login to your account to leave a review.