UP319 Series Ultipleat® SRT High Pressure Filters product photo Primary L

UP319 Series Ultipleat® SRT High Pressure Filters

Features

  • Flows to 600 L/min (160 US gpm)
  • Pressures to 250 bard (3625 psid)
  • Port size 114", 112" and 2"
  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UP319 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.


Contact Us
* Required

Description

Features

  • Flows to 600 L/min (160 US gpm)
  • Pressures to 250 bard (3625 psid)
  • Port size 114", 112" and 2"
  • Patented Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UP319 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.

Specifications

Filter Housing

  • Maximum Working Pressure:
    250 bard (3625 psid) For high cyclic applications, use UH319 series
  • Typical Burst Pressure:
    1050 bard (15,230 psid)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids
  • Bypass Valve Setting:
    4.5 bard (65 psid)
  • Indicator Pressure Setting:
    3.5 bard (50 psid)
  • Materials of Construction:
    Tube: Carbon steel
    Head and Cover: Ductile Cast Iron

Filter Element

  • Filter Element Burst Pressure:
    10 bard (150 psid)
  • Ultipleat SRT Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.
 
Length
Code
‘C’ Option
Overall
Length
mm (in.)
‘C’ Option
Element
Removal
Clearance
mm (in.)
Empty
Weight
kg (lb)
08 442 (17.4) 205 (8.07) 138 29.7 (65.5)
13 577 (22.7) 340 (13.4) 33.4 (73.6)
20 747 (29.4) 510 (20.1) 38 (83.8)
40 1255 (49.4) 1020 (40.2) 52 (114.6)
 








Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

319 Series Filter Elements — bard/1000 L/min (psid/US gpm)

 
Length Code AZ AP AN AS AT
08 5.52 (0.302) 2.30 (0.126) 1.82 (0.100) 1.32 (0.072) 0.82 (0.045)
13 3.31 (0.182) 1.38 (0.076) 1.09 (0.060) 0.79 (0.043) 0.49 (0.027)
20 2.18 (0.120) 0.91 (0.050) 0.72 (0.040) 0.52 (0.029) 0.33 (0.018)
40 1.10 (0.060) 0.46 (0.025) 0.36 (0.020) 0.26 (0.014) 0.16 (0.009)
 

Sample ΔP calculation

UP319 Series 13" length housing with F24 (11⁄2" SAE) split flange ports using AN grade media. Operating conditions 200 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.14 x 1.2/0.9) bard (housing)
+ ((200 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.19 bard (housing) + 0.45 bard (element)
= 0.64 bard (9.3 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

Please select only from the following list of preferred filter housing options.

Available UP319 Series Options

 
UP319CA20 08ZG9
UP319CD20 08ZG9
UP319CA24 08ZG9
UP319CD24 08ZG9
UP319CC20 08ZG9
UP319CF20 08ZG9
UP319CC24 08ZG9
UP319CF24 08ZG9
UP319CA20 13ZG9
UP319CD20 13ZG9
UP319CA24 13ZG9
UP319CD24 13ZG9
UP319CA32 13ZG9
UP319CD32 13ZG9
UP319CC20 13ZG9
UP319CF20 13ZG9
UP319CC24 13ZG9
UP319CF24 13ZG9
UP319CC32 13ZG9
UP319CF32 13ZG9
UP319CA24 20ZG9
UP319CD24 20ZG9
UP319CA32 20ZG9
UP319CD32 20ZG9
UP319CC24 20ZG9
UP319CF24 20ZG9
UP319CC32 20ZG9
UP319CF32 20ZG9
UP319CA32 40ZG9
UP319CD32 40ZG9
UP319CC32 40ZG9
UP319CF32 40ZG9
 

The specification of each filter housing part number is outlined in the tables below.

Section 1

Housing P/N: UP 319 [Table 1] [Table 2] ++ [Table 3] ZG9

Seal Kit P/N: UP 319 SK Z


Note: Pall Ultipleat SRT filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The number '9' at the end of the Housing P/N designates 2 indicator ports, one fitted with a plastic shipping plug and the other with a bleed plug.
*Other seal material options are available; Contact Pall.

Table 1: Housing Orientation Options

 
Code Port
C Cap service (tube up) -standard
 

Table 2: Port Options

 
Code Port
A20 114" SAE J514 straight thread
D20 114" Flange J518C code 61 with 7/16"-14 UNC holding bolts
A24 112" SAE J514 straight thread
D24 112" Flange J518C code 61 with 12"-13 UNC holding bolts
A32 2" SAE J514 straight thread
D32 2" Flange J518C code 61 with 12"-13 UNC holding bolts
C20 114" BSP ISO 228 threads
F20 114" ISO 6162 split flange with M10 x 1.5 holding bolts
C24 112" BSP ISO 228 threads
F24 112" ISO 6162 split flange with M12 x 1.75 holding bolts
C32 2" BSP ISO 228 threads
F32 2" ISO 6162 split flange with M12 x 1.75 holding bolts
 

Table 3: Housing Length Options

 
Code Length (in.)*
08 8
13 13
20 20
40 40
 
* Nominal length

Section 2

Element P/N: UE 319 [Table 1] [Table 2] Z

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 1: Filter Element Options

 
Code ßx(c) ≥1000
based on ISO 16889
CST Rating*
AZ 3 08/04/01
AP 5 12/07/02
AN 7 15/11/04
AS 12 16/13/04
AT 22 17/15/08
 
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205

Table 2: Element Length Options

 
Code Length (in.)*
08 8
13 13
20 20
40 40
 
* Nominal length

Section 3 (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)

Differential Pressure Indicator P/N: RC [Table 1] 091 Z [Table 2] [Table 3] [Table 4]

Note: Two Differential Pressure Indicators can be fitted on this housing
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 1: Differential Pressure Indicator Options*

 
Code Indicator 'H' Dim.
778NZ 'P' type Visual indicator with thermal lockout 21mm (0.83in.)
860MZ 'D' type Visual indicator with no thermal lockout 21mm (0.83in.)
861CZ 'L' type Electrical switch (SPDT) with 6" leads 38mm (1.50in.)
861CZ 'M' type Electrical switch (SPDT) with DIN43650 connector and matching cap 78mm (3.07in.)
861CZ 'R' type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap 89mm (3.50in.)
771BZ 'S' type Electrical switch (SPDT) with 3-pin MS connector 57mm (2.24in.)
 

Table 2: Differential Pressure Indicator Material

 
Code Pressure Setting
Omit Aluminium Alloy Indicator: use at operating pressures < 200 bard (3000 psid)
SS Stainless Steel Indicator: use at operating pressures > 200 bard (3000 psid)
 
* Other setting options are available; contact Pall.

Table 3: 'M' & 'R'-Type Indicator Codes*

 
Code Option
YM 'M' option
YR 'R' option
 
* Use only if 'R' or 'M' Indicator is selected from Table 1

Table 4: 'R' Indicator Options

 
Code Option
110AC 110V AC
220AC 220V AC
24DC 24V DC
 
* Use only if 'R' Indicator is selected from Table 1

Reviews