Product image is a representative example for illustration purposes. Actual product may vary.
Acrodisc® Syringe Filter with Supor® Membrane - 0.8/0.2 µm, 32 mm modified acrylic housing (1000/pkg)
Product ID: 4659 Need this product with different specifications
In stock 4 available
Need More?
Need More?
Pore Size
0.8/0.2 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
Maximum Operating Pressure (bar)
5.2 bar
Maximum Operating Temperature (Metric)
55 °C
Typical Flow Rate
700 mL/min at 2.1 bar (210 kPa, 30 psi)
Documents
Datasheets
Download:Description
Materials of Construction
0.1, 0.2, 0.45, 0.8, 1.2, and 5 µm Effective Filtration Area
13 mm: 1.0 cm2
25 mm: 2.8 cm2
32 mm: 5.8 cm2
37 mm: 7.5 cm2 Inlet/Outlet Connections
Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume(with air purge)
13 mm: <500 µL
25 mm: < 500 µL
32 and 37 mm: < 500 µL Maximum Operating Temperature
55 °C (131 °F) Maximum Operating Pressure
5.2 bar (520 kPa, 75 psi) Typical Water Flow Rate mL/min at 3.1 bar (310 kPa, 45 psi)
0.1 μm, 25 mm: 35
0.1 μm, 32 mm: >75
0.2 μm, 13 mm: 22
0.2 μm, 25 mm: 175
0.2 μm, 32 mm: >330
0.45 μm, 13 mm: 35
0.45 μm, 25 mm: 300
0.45 μm, 32 mm: >560
0.8 μm, 13 mm: 150
0.8 μm, 25 mm: 700
0.8/0.2 μm, 25 mm: >400
0.8/0.2 μm, 32 mm: >400
1.2 μm, 32 mm: >1500
5 μm, 32 mm: >1725
GF/0.2 μm, 37 mm (Serum
Acrodisc Filter): 425 Endotoxin Level< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test< 0.4 EU/mL using Limulus Amoebocyte Lysate (LAL) test - 32 mm Acrodisc SterilizationSterilized by gamma irradiation and individually blister packaged. All bulk packages provided non-sterile including PN 4504, 4506, 4508, 4509, 4655, 4653, 4659, 4660, 4661, 4662, 4668, and 4692.
0.8/0.2 µm, 32 mm (50/pkg)
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."
Filter Media: Supor membrane [hydrophilic polyethersulfone (PES)]
Serum Acrodisc Prefilter Media: Binder-free borosilicate glass
Acrodisc Housing:
- 13 mm: Polypropylene
- 25 and 32 mm: Modified acrylic
- 37 mm: Polypropylene
0.1, 0.2, 0.45, 0.8, 1.2, and 5 µm Effective Filtration Area
13 mm: 1.0 cm2
25 mm: 2.8 cm2
32 mm: 5.8 cm2
37 mm: 7.5 cm2 Inlet/Outlet Connections
Female luer lock inlet, male slip luer outlet Typical Hold-Up Volume(with air purge)
13 mm: <500 µL
25 mm: < 500 µL
32 and 37 mm: < 500 µL Maximum Operating Temperature
55 °C (131 °F) Maximum Operating Pressure
5.2 bar (520 kPa, 75 psi) Typical Water Flow Rate mL/min at 3.1 bar (310 kPa, 45 psi)
0.1 μm, 25 mm: 35
0.1 μm, 32 mm: >75
0.2 μm, 13 mm: 22
0.2 μm, 25 mm: 175
0.2 μm, 32 mm: >330
0.45 μm, 13 mm: 35
0.45 μm, 25 mm: 300
0.45 μm, 32 mm: >560
0.8 μm, 13 mm: 150
0.8 μm, 25 mm: 700
0.8/0.2 μm, 25 mm: >400
0.8/0.2 μm, 32 mm: >400
1.2 μm, 32 mm: >1500
5 μm, 32 mm: >1725
GF/0.2 μm, 37 mm (Serum
Acrodisc Filter): 425 Endotoxin Level< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test< 0.4 EU/mL using Limulus Amoebocyte Lysate (LAL) test - 32 mm Acrodisc SterilizationSterilized by gamma irradiation and individually blister packaged. All bulk packages provided non-sterile including PN 4504, 4506, 4508, 4509, 4655, 4653, 4659, 4660, 4661, 4662, 4668, and 4692.
0.8/0.2 µm, 32 mm (50/pkg)
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."
Type
Syringe Filters
Use
HPLC/UHPLC SAMPLE PREPARATION
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.