Free ground shipping on Laboratory products for registered Credit Card users.
AcroPrep Advance Filter Plates for Aqueous Filtration - 350 µL, 0.2 µm Supor membrane (10/pkg) product photo Primary L

AcroPrep Advance Filter Plates for Aqueous Filtration - 350 µL, 0.2 µm Supor membrane (10/pkg)

8019
$ 183.84
Unit of Measure
EA
Min Order Qty
1


* Required
Need this product with different specifications?
Click here for more options
Description
AcroPrep Advance Filter Plates for Aqueous Filtration, 350 _L, 0.2 _m Supor membrane smooth well wall provides efficient bead recovery, ensuring reproducible results lot after lot., Pall AcroPrep Advance Filter Plates for Aqueous Filtration, 350 _L, 0.2 _m Supor membrane (10/pkg)
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520."
Applications
  • Bead-based multiplexing assays
  • Flow cytometry
Specifications

Materials of Construction

  • Filter Media: PP/PE non-woven (polypropylene/polyethylene) and Supor (polyethersulfone) membrane
  • Plate Housing: Polyproylene
  • Lid: Polystyrene

Dimensions

  • Length: 12.8 cm (5.0 in.)
  • Width: 8.6 cm (3.4 in.)
  • Height With Lid: 1.8 cm (0.7 in.)
  • Height Without Lid: 350 μL, 1.4 cm (0.6 in.)

Well-Bottom Area

  • 0.25 cm2

Recommended Working Volume

  • 350 μL: < 300 μL

Recommended Operating Vacuum

  • > 25.4 cm Hg (10 in. Hg)

Recommended Centrifugal Force

  • 1,500 x g

Typical Processing Time

  • Vacuum: 2 seconds
  • Centrifuge: < 2 minutes

Typical Hold-Up Volume

  • Vacuum: 5 μL
  • Centrifuge: 3 μL
Performance

Pall Supor Membrane Reduces the Occurrence of False Positive Results




The serological immunoassays were performed with multiple lots of xMAP microspheres in both the Pall Supor and Competitor M filter plates. The results from these filter plates were read with one Luminex LX100 Instrument. The responses represent the reactivity toward microspheres without proteins coupled to them to maximize the indications of false positive “non-specific” reactivity by the microspheres. In all lots of microspheres tested, the Pall Supor filter plates exhibited a marked reduction in non-specific reactivity than competitive plates. Data generated in conjunction with Luminex Corporation.
Type
Plates
Use
Protein purification
Application
Protein Concentration & Buffer Exchange
Segment
Protein Sample Prep & Detection
Shop Laboratory Products