Acrodisc® Syringe Filters with Supor® Membrane product photo Primary L

Acrodisc® Syringe Filters with Supor® Membrane

Syringe Filters with High Flow Rates and Low Protein Binding

  • Superior flow rates and higher throughputs than competitive devices.
  • Low protein binding to minimize sample loss.
  • Pre-sterilized products are sterilized by gamma irradiation to eliminate potential contamination by EtO residuals.
  • A range of sizes (13 to 37 mm) accommodates sample volumes from < 10 to 150 mL.
  • Acrodisc PF and Serum Acrodisc syringe filters feature built-in prefilter for increased throughput of difficult-to-filter liquids.
  • Reduces mycoplasma with the use of 0.1 μm pore size.
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520."


* Required

Acrodisc 13mm Nonsterile

List Price
$ 1,405.83

Acrodisc 25mm Nonsterile

List Price
$ 1,806.99
List Price
$ 1,836.88
List Price
$ 1,843.14
List Price
$ 1,815.85
List Price
$ 2,495.04

Acrodisc 32mm Nonsterile

List Price
$ 2,238.06
List Price
$ 2,438.30
List Price
$ 2,282.08
List Price
$ 2,079.89
List Price
$ 2,282.08
List Price
$ 2,282.08

Acrodisc PF Syringe Filters with Supor Membrane, Sterile

List Price
$ 140.00
List Price
$ 150.00

Acrodisc Syringe Filters with Supor Membrane, Sterile

List Price
$ 171.02
List Price
$ 171.02
List Price
$ 174.20
List Price
$ 130.00
List Price
$ 130.00
List Price
$ 130.00
List Price
$ 130.00
List Price
$ 140.00
List Price
$ 140.00
List Price
$ 140.00
List Price
$ 140.00
List Price
$ 140.00

Serum Acrodisc Syringe Filter with Supor Membrane, Sterile

List Price
$ 121.76
Description

Syringe Filters with High Flow Rates and Low Protein Binding

  • Superior flow rates and higher throughputs than competitive devices.
  • Low protein binding to minimize sample loss.
  • Pre-sterilized products are sterilized by gamma irradiation to eliminate potential contamination by EtO residuals.
  • A range of sizes (13 to 37 mm) accommodates sample volumes from < 10 to 150 mL.
  • Acrodisc PF and Serum Acrodisc syringe filters feature built-in prefilter for increased throughput of difficult-to-filter liquids.
  • Reduces mycoplasma with the use of 0.1 μm pore size.
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520."
Applications
  • 0.1 and 0.2 μm pore sizes provide sterilization of small volumes of buffers, culture media, and additives.
  • Acrodisc PF and Serum Acrodisc syringe filters are ideal for clarification/sterilization of viscous or particulate-laden solutions.
  • Use larger pore size filters for prefiltration and particulate removal.
Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520.
Specifications

Materials of Construction

Filter Media: Supor membrane [hydrophilic polyethersulfone (PES)]
Serum Acrodisc Prefilter Media: Binder-free borosilicate glass
Acrodisc Housing:
  13 mm: Polypropylene
  25 and 32 mm: Modified acrylic
  37 mm: Polypropylene
Serum Acrodisc Housing: ABS 

Pore Size

0.1, 0.2, 0.45, 0.8, 1.2, and 5 µm

Effective Filtration Area

13 mm: 1.0 cm2
25 mm: 2.8 cm2
32 mm: 5.8 cm2
37 mm: 7.5 cm2

Inlet/Outlet Connections

Female luer lock inlet, male slip luer outlet

Typical Hold-Up Volume

(with air purge)
13 mm: < 28 µL
25 mm: < 70 µL
32 and 37 mm: <100 µL

Maximum Operating Temperature

55 °C (131 °F)

Maximum Operating Pressure

5.2 bar (520 kPa, 75 psi)

Typical Water Flow Rate

mL/min at 3.1 bar (310 kPa, 45 psi)
0.1 μm, 25 mm: 35
0.1 μm, 32 mm: 100
0.2 μm, 13 mm: 22
0.2 μm, 25 mm: 175
0.2 μm, 32 mm: 490
0.45 μm, 13 mm: 35
0.45 μm, 25 mm: 300
0.45 μm, 32 mm: 700
0.8 μm, 13 mm: 150
0.8 μm, 25 mm: 700
0.8/0.2 μm, 25 mm: 145
0.8/0.2 μm, 32 mm: 440
1.2 μm, 32 mm: 1700
5 μm, 32 mm: 1750
GF/0.2 μm, 37 mm (Serum
Acrodisc Filter): 425

Endotoxin Level

< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test

Biological Safety

Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>

Sterilization

Sterilized by gamma irradiation and individually blister packaged. All bulk packages provided non-sterile including PN 4504, 4506, 4508, 4509, 4655, 4653, 4659, 4660, 4661, 4662, 4668, and 4692.
Performance

Built-In Prefilter Enhances Throughput of Viscous, Particulate-Laden, or Proteinaceous Solutions
Built-In Prefilter Enhances Throughput of Viscous, Particulate-Laden, or Proteinaceous Solutions


Acrodisc and Acrodisc PF syringe filters with 0.2 μm Supor membrane were challenged with bovine serum or a bacterial culture (107 cfu/mL) at a constant pressure of 1.4 bar (140 kPa, 20 psi).

Acrodisc with Supor Membrane

Type
Syringe Filter
Use
Microfiltration
Application
Sterile Filtration
Segment
Sterile Filtration and Clarification