Free ground shipping on Laboratory products for registered Credit Card users.
AcroPak™ 400, 800, and 1500 Capsules With Supor® EKV Membrane product photo Primary L

AcroPak™ 400, 800, and 1500 Capsules With Supor® EKV Membrane

For Cost-Effective Filtration of Buffers, Tissue Culture Media, and Other Biological Solutions

  • Newer technology recommended for simplified scale-up
  • Disposable design reduces labor costs associated with assembling, cleaning, and testing stainless steel filter holders
  • Encapsulated format for ease of use
  • Extended life with built-in MachV asymmetric prefilter layer for maximum flow and throughput performance
  • Low adsorption and high chemical compatibility with hydrophilic polyethersulfone membrane for high compatibility over the entire pH range and low protein binding
  • Gamma-irradiated, non-pyrogenic, and non-cytotoxic
  • Inherently hydrophilic for reliable integrity testing 
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520."

Video: Using an AcroPak Filter With a Peristaltic Pump



* Required
Need Help?
Download Datasheet

AcroPak 1500 Capsules With Supor EKV Membrane

List Price
$ 200.00
List Price
$ 200.00

AcroPak 400 Capsules With Supor EKV Membrane

List Price
$ 106.00
List Price
$ 106.00

AcroPak 800 Capsules With Supor EKV Membrane

List Price
$ 160.00
List Price
$ 160.00
Description

For Cost-Effective Filtration of Buffers, Tissue Culture Media, and Other Biological Solutions

  • Newer technology recommended for simplified scale-up
  • Disposable design reduces labor costs associated with assembling, cleaning, and testing stainless steel filter holders
  • Encapsulated format for ease of use
  • Extended life with built-in MachV asymmetric prefilter layer for maximum flow and throughput performance
  • Low adsorption and high chemical compatibility with hydrophilic polyethersulfone membrane for high compatibility over the entire pH range and low protein binding
  • Gamma-irradiated, non-pyrogenic, and non-cytotoxic
  • Inherently hydrophilic for reliable integrity testing 
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please contact Labcustomersupport@pall.com or call 1-800-521-1520."

Video: Using an AcroPak Filter With a Peristaltic Pump

Applications
  • Suitable for sterile filtration of a wide range of fluids, including:
    • Buffers
    • Biological fluids
    • Cell culture media
    • Ophthalmic products
Specifications

Materials of Construction

  • Filter Media: Supor EKV [hydrophilic polyethersulfone (PES)] membrane
  • Housing, Vent Plug, and Support Material: Polypropylene
  • Filling Bell: Polycarbonate (no filling bell on sanitary flange option)
  • Sealing Technology: Thermal bonding without adhesives

Pore Size

  • 0.2 μm

Effective Filtration Area

  • 400 Series: 375 cm2
  • 800 Series: 750 cm2
  • 1500 Series: 1500 cm2

Dimensions

  • Housing Diameter (including valves): 9.4 cm (3.7 in.)
  • 400 Series Housing Length:
       12460: 11.7 cm (4.6 in.)
       12461: 15.7 cm (6.2 in.)
  • 800 Series Housing Length:
       12463: 15.7 cm (6.2 in.)
       12464: 19.7 cm (7.7 in.)
  • 1500 Series Housing Length:
       12466: 17.4 cm (6.8 in.)
       12467: 21.0 cm (8.3 in.)

Inlet/Outlet Connections

  • 400 Series
       12460: 25 - 38 mm (1 - 1.5 in.) sanitary flange inlet/outlet connection
       12461: 13 mm (1/2 in.) hose barb inlet/outlet connection
  • 800 Series
       12463: 25 - 38 mm (1 - 1.5 in.) sanitary flange inlet/outlet connection
       12464: 13 mm (1/2 in.) hose barb inlet/outlet connection
  • 1500 Series
       12466: 25 - 38 mm (1 - 1.5 in.) sanitary flange inlet/outlet connection
       12467: 13 mm (1/2 in.) hose barb inlet/outlet connection

Maximum Operating Temperature

  • 40 ºC (104 ºF) at 4.0 bar (400 kPa, 58 psi)

Maximum Operating Pressure

  • 5.2 bar (520 kPa, 75 psi) at 20 ºC (68 ºF)

Recommended Integrity Test Minimum Bubble Point - Water

  • 3.32 bar (332 kPa, 48 psi) Typical Water Flow Rate

Typical Water Flow Rate

  • 400 Series: 700 mL/min/0.1 bar (483 mL/min/psi)
  • 800 Series: 1.5 L/min/0.1 bar (1.0 L/min/psi)
  • 1500 Series: 3.2 L/min/0.1 bar (2.2 L/min/psi)

Bacterial Retention

  • Lot samples retain a minimum of 107 cfu/cm2 of B. diminuta per modified ASTM F838, current revision

Endotoxin Level

  • < 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test

Biological Safety

  • Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>

Sterilization

  • Sterilized by gamma irradiation and individually packaged
Type
Capsule Filter
Use
Microfiltration
Application
Sterile Filtration
Product Summary
For cost-effective filtration of buffers, tissue culture media, and other biological solutions. Disposable design reduces labor costs associated with assembling, cleaning, and testing stainless steel filter holders.
Segment
Shop Laboratory Products
Sterile Filtration and Clarification