Ultralab™ Systems & Ultrareservoir™ Containers

Simplify Processing of 100 mL to 5 L Volumes When Using the Ultrasette™ Device

  • Self-contained siphoning units allow continuous buffer exchange
  • Uses less liquid with less handling and mess than conventional dialysis systems
  • Constructed of clear acrylic with easy-to-read volume graduations
  • Connections located in base plate for easy access and minimal sample hold-up
  • Feed pressure gauge monitors sample processing
  • Three-way sampling valve allows maximum sample recovery without decanting
  • Peristaltic pump action minimizes shear of sensitive molecules, eliminates air in the system, and reduces foaming
  • A variable speed controller allows precise adjustment of crossflow during sample processing
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."


Need Help?
Ask a Question
* Required

Order Products

Spare Parts and Accessories

Ultralab Systems with 115 V pump

Ultralab Systems with 230 V Pump

Ultrareservoir Containers

Description

Simplify Processing of 100 mL to 5 L Volumes When Using the Ultrasette™ Device

  • Self-contained siphoning units allow continuous buffer exchange
  • Uses less liquid with less handling and mess than conventional dialysis systems
  • Constructed of clear acrylic with easy-to-read volume graduations
  • Connections located in base plate for easy access and minimal sample hold-up
  • Feed pressure gauge monitors sample processing
  • Three-way sampling valve allows maximum sample recovery without decanting
  • Peristaltic pump action minimizes shear of sensitive molecules, eliminates air in the system, and reduces foaming
  • A variable speed controller allows precise adjustment of crossflow during sample processing
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."

Specifications

Ultrareservoir Containers

Total Volume 500 mL 2 L 5 L
Materials of Construction
Sample Reservoir Acrylic Acrylic Acrylic
Valves, Lid,
and Barb Connectors
Polypropylene Polypropylene Polypropylene
O-ring (Lid) EPR* EPR* EPR*
Gauge Stainless steel Stainless steel Stainless steel
Dimensions
(Excluding Valves)
12.7 W x 12.7 D x 19.1 H cm
(5W x 5D x 7.5H in.)
15.2 W x 15.2 D x 22.9 H cm
(6W x 6D x 9H in.)
20.3 W x 20.3 D x 27.9 H cm
(8W x 8D x 11H in.)
Typical Hold-up
Volume
< 2 mL < 2 mL < 5 mL
Minimum Recirculating
Volume
15 - 20 mL 20 - 30 mL 20 - 30 mL
Inlet/Outlet
Connections
4.0 mm (5/32 in.) 6.4 mm (1/4 in.) 6.4 mm (1/4 in.)
Weight 0.9 kg (2 lb.) 1.8 kg (4 lb.) 3.0 kg (6.6 lb.)

*Ethylene Propylene Rubber

Applications

  • For concentration of dilute sample volumes of up to 5 L
  • For use in diafiltration procedures which are faster and more efficient than dialysis for buffer exchange and desalting

Type

Systems

FAQs

1 Q. How many times can a Minimate™ capsules be reused?
A. There are no specific guidelines for the total number of times a Minimate capsule can be reused as it is dependent on usage frequency, particles in the fluid, clean-in-place (CIP) procedure, normalized water permeability (NWP), and integrity testing. Pall recommends that a NWP value is taken on all new Minimate capsules prior use so after use and CIP, NWP can be re-evaluated. Typically, after CIP/regeneration the NWP of capsules should be >75% of the original NWP value, if it is not Pall recommends doing the cleaning procedure again. When the NWP value on a used Minimate capsule drops below 50% of the original NWP value, it is suggested that a new capsule is used.

2 Q. How many times can a Centramate™ cassettes be reused?
A. There are no specific guidelines for the total number of times a Centramate cassette can be reused as it is dependent on usage frequency, particles in the fluid, clean-in-place (CIP) procedure, normalized water permeability (NWP), and integrity testing. Pall recommends that a NWP value is taken on all new Centramate cassettes prior use so after use and CIP, NWP can be re-evaluated. Typically, after CIP/regeneration the NWP of cassettes should be >75% of the original NWP value, if it is not Pall recommends doing the cleaning procedure again. When the NWP value on a used Centramate cassette drops below 50% of the original NWP value, it is suggested that a new cassette is used.

3 Q. When should I order Centramate™ vs Centramate PE?
A. Certain applications require a fluid path that is free from metal. Our standard Centramate has stainless steel fittings and a 100% stainless steel cassette holder, so it would not be a good option for these applications. Pall’s Centramate PE has plastic fittings and the fluid path of the holder is polyethylene plastic. The pressure gauge that comes standard with the Centramate PE will have a stainless steel pathway, but the ¼” NPT fittings the system uses makes it easy to use a pressure gauge whose wettable parts will be free from metal.

4 Q. What do I need to attach an LV Centramate™ to the Minimate™ EVO system?
A.
Pall recommends ordering the Minimate EVO Fittings kit, PN 97014, to get the additional 3-way stop cocks, hose barb adapters, and tubing needed to properly connect the LV Centramate holder to the Minimate EVO system. Contact your Pall representative or technical support if you have further questions.

5 Q. How many cassettes can I stack in a Centramate™ or Centramate PE?
A.
You can stack up to 5 0.1 m2 T12 cassettes on Centramate, giving you up to 0.5m2 of effective filtration area. For the Centramate PE, only 4 0.1 m2 T12 cassettes will fit because of the thicker PE base. Stacking multiple cassettes in the holders increases the surface area of the membrane which gives a higher permeate flow rate and increases the throughput.

6 Q. Guidance on average recirculation flow rates and permeate flux rates for the Minimate™, LV Centramate™, Centramate PE/SS.
A.
For the Minimate we recommend a recirculation flow rate of 30-40 ml/min. If the inlet pressure is >30PSI at these flow rates, the rate should be decreased. A typical permeate flux rate will be 4 ml/min. For the LV Centramate we recommend a recirculation flow rate of 120-160 ml/min. If the inlet pressure is >30PSI at these flow rates, the rate should be decreased. A typical permeate flux rate will be 15 ml/min. For the Centramate and Centramate PE we recommend a recirculation flow rate of 600-800 ml/min. If the inlet pressure is >30PSI at these flow rates, the rate should be decreased. A typical permeate flux rate will be 75 ml/min. Note: These are typical values. Actual values may be higher or lower depending on the membr