Pediatric IV Filter product photo Primary L

Pediatric IV Filter

Air-eliminating filter protects against air emboli in adult, pediatric, and neonate patients.

  • Patented vent design allows filter to be taped down in any position.
  • Easy priming and accurate drug delivery - even at low drug delivery rates.
  • Rotating hub.
  • Male slip.
  • Capping available.
  • Small, compact design makes it ideal for alternate site and ambulatory care applications.
  • Supor® membrane's low protein binding characteristics provide minimal adsorption and contain no external wetting agents or surfactants which might introduce unwanted extractables downstream of the filter.
  • Housing designed for comfortable, secure placement in even the most difficult body areas, such as the scalp.
  • Materials of construction contain no natural rubber latex, or latex derivatives, PVC, or hydroxyvinyl chloride.
  • 0.2 µm Supor membrane is retentive of B. diminuta and meets USP 25/NF20 requirements for a sterilizing grade filter per ASTM F838-83 test methods.


* Required
Need Help?
Download Datasheet
Description

Air-eliminating filter protects against air emboli in adult, pediatric, and neonate patients.

  • Patented vent design allows filter to be taped down in any position.
  • Easy priming and accurate drug delivery - even at low drug delivery rates.
  • Rotating hub.
  • Male slip.
  • Capping available.
  • Small, compact design makes it ideal for alternate site and ambulatory care applications.
  • Supor® membrane's low protein binding characteristics provide minimal adsorption and contain no external wetting agents or surfactants which might introduce unwanted extractables downstream of the filter.
  • Housing designed for comfortable, secure placement in even the most difficult body areas, such as the scalp.
  • Materials of construction contain no natural rubber latex, or latex derivatives, PVC, or hydroxyvinyl chloride.
  • 0.2 µm Supor membrane is retentive of B. diminuta and meets USP 25/NF20 requirements for a sterilizing grade filter per ASTM F838-83 test methods.
Applications
  • Neonate and pediatric IV therapy
  • Chemotherapy
  • Antibiotic therapy
  • Nutrient admixture
Specifications

Materials of Construction
Filter Media: Supor® (polyethersulfone) membrane
Housing: Modified acrylic
Vent: 0.02 µm supported PTFE

Pore Size
0.2, 1.2 µm, custom products available

Effective Filtration Area
4.5 cm2

Dimensions
56 x 34 mm (2.187 x 1.312 in.)

Priming Volume
0.7 mL

Inlet/Outlet Connections
FLL/MLL, (male luer inner diameter accepts microbore tubing)
MSL

Maximum Operating Temperature
55 °C (131 °F)

Maximum Operating Pressure
3.1 bar (45 psi)

Minimum Water Bubble Point
0.2 µm: ≥ 3.1 bar (45 psi)
1.2 µm: ≥ 0.3 bar (5 psi)

Minimum Water Flow Rate
0.2 µm: ≥ 10 mL/min at 91 cm (36 in.) head pressure
1.2 µm: ≥ 90 mL/min at 91 cm (36 in.) head pressure

Pyrogenicity
< 0.25 EU/mL using the LAL test method

Sterilization Compatibility
EtO, gamma irradiation (tested to 50 kGy)

Biological Safety
Materials of construction pass USP Biological Reactivity Tests, In Vivo <88>

Type
Membranes and Materials, Sheet Filters and Modules
Use
Filtration
Ordering Information
Part Number Pore Size Description
6074422 0.2 µm Supor membrane, clear housing, non-sterile, FLL/MLL
6074423 0.2 µm Supor membrane, clear housing, non-sterile, MSL
6104423 1.2 µm Supor membrane, clear/blue housing, non-sterile, DLL
Application