Fluorodyne® II DBL - Kleenpak™ Nova Capsules product photo Primary L

Fluorodyne® II DBL - Kleenpak™ Nova Capsules

These 0.45 micron capsule filters are predominantly used in pre-filtration applications or viscous fluid filtrations. Validated removal of Serratia marcescens (ATCC 14756) with a typical titer reduction (TR) of > 106 ensures that they are also suitable for bioburden control. A serial layer (0.65/0.45 micron) membrane construction allows for high throughputs and high flow rates compared with other 0.45 micron-rated filters.

Kleenpak Nova capsules are designed for use in medium-to-large-scale production environments (100 L to > 1000 L) and are often selected by the end-user following scaling studies using the smaller Kleenpak capsule formats. Kleenpak Nova capsules can be offered in ‘In-line’'(NP) or ‘T’style (NT) inlet/outlet configurations with sanitary flange or hose barb fittings. With the AB-style filter cartridge at their core, Kleenpak Nova filter capsules can be supplied with the most comprehensive range of filter media among all of 'Pall's single-use capsules.

Key Features and Benefits

  • Encapsulated format for higher flexibility, minimized cleaning, and low installation costs
  • Incorporated prefiltration layer
  • Low extractables  
  • High protein transmission
  • Rapid preservative recoveries 
  • Easy integrity testing 
  • Compatible with organic solvents, acids, and chemicals¹
  • Resin and surfactant-free 
  • Melt-sealed, non-shedding
    ¹ Except for ketones and amides

Quality Standards

  • Manufactured for use in conformance with cGMP 
  • 100% integrity tested
  • ISO 9000 Certified Quality System
  • Meets USP Biological Reactivity Test in vivo for Class VI-121 °C plastics
  • Every filter tested during manufacture
  • Test correlated to microbial retention
  • Certificate of Test provided includes
    • Fabrication Integrity 
    • Bacterial Retention 
    • Materials of Construction
    • Effluent quality for cleanliness, TOC and water conductivity, pH and pyrogens


Need Help?
Ask a Question
* Required

Order Products

Currently shopping by | Clear All

Format

Kleenpak Nova

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 30-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 30-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NT8DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 10-inch filter, 1-1½ in sanitary flange connections, gamma irradiated product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 10-inch filter, 1-1½ in sanitary flange connections, gamma irradiated

Product ID: NP6DBLP1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 20-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 20-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NP7DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 30-inch filter, 1-1½ in sanitary flange connections, gamma irradiated product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 30-inch filter, 1-1½ in sanitary flange connections, gamma irradiated

Product ID: NT8DBLP1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 20-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 20-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NT7DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 20-inch filter, 1-1½ in sanitary flange connections, gamma irradiated product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 20-inch filter, 1-1½ in sanitary flange connections, gamma irradiated

Product ID: NT7DBLP1S
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 30-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 30-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NP8DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 10-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, T style, 10-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NT6DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes
Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 10-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DBL membrane in Kleenpak™ Nova capsule, 0.45 µm removal rating, in-line style, 10-inch filter, 1-1½ in sanitary flange connections, suitable for gamma irradiation

Product ID: NP6DBLP1G
Unit of Measure
1/EA
Min Order Qty
1
Membrane Material
Polyvinylidene fluoride (PVDF)
Sterilization Option(s)
Suitable for Autoclave, Suitable for Gamma Irradiation
See All Attributes

Documents

Datasheets

Download: English

Description

These 0.45 micron capsule filters are predominantly used in pre-filtration applications or viscous fluid filtrations. Validated removal of Serratia marcescens (ATCC 14756) with a typical titer reduction (TR) of > 106 ensures that they are also suitable for bioburden control. A serial layer (0.65/0.45 micron) membrane construction allows for high throughputs and high flow rates compared with other 0.45 micron-rated filters.

Kleenpak Nova capsules are designed for use in medium-to-large-scale production environments (100 L to > 1000 L) and are often selected by the end-user following scaling studies using the smaller Kleenpak capsule formats. Kleenpak Nova capsules can be offered in ‘In-line’'(NP) or ‘T’style (NT) inlet/outlet configurations with sanitary flange or hose barb fittings. With the AB-style filter cartridge at their core, Kleenpak Nova filter capsules can be supplied with the most comprehensive range of filter media among all of 'Pall's single-use capsules.

Key Features and Benefits

  • Encapsulated format for higher flexibility, minimized cleaning, and low installation costs
  • Incorporated prefiltration layer
  • Low extractables  
  • High protein transmission
  • Rapid preservative recoveries 
  • Easy integrity testing 
  • Compatible with organic solvents, acids, and chemicals¹
  • Resin and surfactant-free 
  • Melt-sealed, non-shedding
    ¹ Except for ketones and amides

Quality Standards

  • Manufactured for use in conformance with cGMP 
  • 100% integrity tested
  • ISO 9000 Certified Quality System
  • Meets USP Biological Reactivity Test in vivo for Class VI-121 °C plastics
  • Every filter tested during manufacture
  • Test correlated to microbial retention
  • Certificate of Test provided includes
    • Fabrication Integrity 
    • Bacterial Retention 
    • Materials of Construction
    • Effluent quality for cleanliness, TOC and water conductivity, pH and pyrogens

Specifications

Materials of Construction

Filter Membrane  Hydrophilic modified PVDF
Support/Drainage  Polypropylene
Core/End Caps  Polypropylene
Cage  Polypropylene
O-rings  Silicone elastomer
Sealing Technology  Thermal bonding without adhesives
Housing Bowl  Polypropylene
 Housing Head  Polypropylene

Operating Parameters¹

 Maximum Temperature 40 °C
 Maximum Operating Pressure 3 bar (44 psi) at 40 °C
 Maximum Differential Pressure (Forward Direction) 3 bar (44 psi) at 40 °C
¹ In compatible fluids which do not soften, swell or adversely affect the filter or its materials of construction

Sterilization²

 Autoclavable (G option only)  3 x 60 minutes at 125 °C
 Gamma Irradiation (G option only)  Maximum of 50 kGy
² Pre-sterilized Kleenpak Nova capsules must not be re-sterilized. Kleenpak Nova capsules must not be sterilized in-situ by passing steam under pressure

Typical Extractables in Water at 20 °C³

G option  < 10 mg per 254 mm (10 in.) capsule
S option  < 20 mg per 254 mm (10 in.) capsule
³ Tested on elements without pre-flushing

Nominal Dimensions

In-Line (P-style) NP6 NP7 NP8
Maximum diameter including valves 154 mm (6.1 in.) 154 mm (6.1 in.) 154 mm (6.1in.)
Length with hose barb inlet/outlet 397 mm (15.6 in.) 644 mm (25.4 in.) 895 mm (35.2 in.)
Length with sanitary inlet/outlet 335 mm (13.2 in.) 584 mm (23.0 in.) 834 mm (32.8 in.)
T-style NT6 NT7 NT8
Maximum diameter including valves 240 mm (9.5 in.) 240 mm (9.5 in.) 240 mm (9.5 in.)
Length 349 mm (13.7 in.) 598 mm (23.5 in) 848 mm (33.4 in.)


Nominal Effective Filter Area (EFA)

5500 cm² per 254 mm capsule (5.9 ft² per 10 in. capsule)

Integrity Test Values (Air test gas, water wet)*

 Max. allowable forward flow values for
254 mm (10 in.) capsule at 20ºC 
13 mL/min at 1240 mbar (18 psi)
* Contact Pall for multi-element integrity test values and recommended test procedures


Type

Filter Capsules

Use

Bioburden Filtration

Product Summary

Fluorodyne® II DBL Membrane in Kleenpak™ Nova 0.45 micron capsule filters are encapsulated for higher flexibility while minimizing cleaning and installation costs. Using both in-line and T-style configurations, the user can easily implement this prefiltration system. Capsules can be supplied with a wide arrange of filter media, including single-use products. Each capsule is 100% integrity tested and meets ISO 9000 Certified Quality System standards.

Reviews

We'd like your opinion! Rate and review this item