Cadence™ Single-Pass Tangential Flow Filtration Modules and Systems
Order Products
Effective Filtration Area
1700 cm²

Cadence™ Single-Pass TFF Module, Delta regenerated cellulose membrane, 10 kDa molecular weight cut-off (MWCO), 0.17 m² effective filtration area (EFA)
1/EA
1
This product is currently not available. Please contact us for more information.

Cadence™ Single-Pass TFF Module, Delta regenerated cellulose membrane, 30 kDa molecular weight cut-off (MWCO), 0.17 m² effective filtration area (EFA)
1/EA
1
Description
Eliminate the Recirculation Loop and Streamline Operations to Optimize Downstream Processing
Cadence Single-Pass TFF ( SPTFF ) is a patented breakthrough technology that allows direct flow-through concentration with no recirculation of product. SPTFF enables high concentration of shear sensitive proteins and antibodies >160 grams/liter. What makes this possible is a unique flow path design and staging of cassettes in a serial flow.See the Cadence™ system in action.
Single-pass TFF patent numbers:
- US patent number 7.682.511 B2
- US patent number 7.384.549 B2
- US patent number 7.967.987 B2
- US patent number 8.157.999
This exciting new technology leads to
economic and practical benefits, including:
- Increased yield of product due to improved recovery capability and lower hold-up volume.
- Increased final product concentration due to high concentration factor capability.
- Elimination of product damage or aggregation due to reduced residence time and shear exposure.
- Ability to couple the concentration of product before or after other downstream process steps, consequently optimizing other steps and reducing in-process pool tank volumes.
- Available in single use format.
Cadence single-pass TFF modules and systems can be easily integrated with other downstream processes such as chromatography or virus removal.
Using Cadence modules with Delta membrane, the innovative benefits of Single-Pass TFF technology are enhanced by the proven high flux, high selectivity, and low protein binding attributes of Delta regenerated cellulose membrane cassettes.
Optimize Economic and Operational Benefits
- Enhance downstream processing to increase capacity and reduce costs – Cadence systems can eliminate or reduce intermediate storage tanks and associated cleaning of tanks when using the systems for in-process volume reduction before or after existing steps.
- Increase yield and achieve high product recovery > 98 % – The single-pass TFF process collects most of the process volume during the process run, leaving only a small percentage of the product in the module at the end of the run. This small percentage of product can be easily recovered due to the low hold-up volume in the system.
- Enable high concentration factors > 20X – High concentration factors are achieved due to the staging of cassettes in series, which results in high conversions of feed-to-permeate in one flow path. This is accomplished by optimizing the module staging configuration based on cassette performance for a particular application.
- Optimize processing of highly shear-sensitive products – Processing results in only one pass through the pump and cassette, reducing shear exposure. For products sensitive to pumping, the pump can be completely eliminated by using pressurized vessels to flow the process fluid through the module. Further benefits are achieved by eliminating any mixing or foaming issues associated with the feed tank.
- Use smaller, more compact systems – Cadence systems require less pump capacity, allowing smaller piping or tubing diameters for a more compact system design with lower working and hold-up volumes.
- Simplify installation and use – Cadence modules are supplied preassembled. The modules’ feed, retentate and permeate ports are easily connected to clearly-marked system ports.
Product Platform
Innovative single-pass TFF processing takes place within Cadence modules. Cadence modules incorporate Pall’s proven T-Series cassettes with Delta membrane, and are available in different sizes to accommodate various processing volumes (see Ordering Information). Cadence modules are designed for use with a Pall Cadence single-pass TFF system. (Contact Pall for information on a Cadence system to meet your application requirements.)
Cadence Modules Incorporate High Performance T-Series Cassettes with Delta Membrane
Delta regenerated cellulose membrane offers high flux and selectivity. The membrane has been specifically developed to minimize protein binding to the surface and interstitial structure of the membrane. Inherently hydrophilic, this membrane shows low protein adsorption properties and is optimal for processes involving very hydrophilic proteins. Delta regenerated cellulose membrane shows low fouling characteristics, allowing consistent performance or flux from run to run. It is easy to clean and typically recovers normalized water permeability (NWP) by using 0.1 N NaOH.
Cadence T01 Module Installed in Holder

Specifications
The operating conditions and module configurations for any single-pass TFF process must be established by performing trials and analyzing results. Pall’s Technical Support Group is available to assist in conducting trials to select configurations and develop operating conditions necessary to achieve the desired process objectives.
Cadence Module Materials of Construction | |
Membrane | Delta regenerated cellulose, 10 kD |
Support | Polypropylene |
Screens | Polypropylene |
Encapsulant | Polyurethane with white pigment (TiO2) |
Permeate Seals | Medical grade, platinum cured silicone |
Gaskets | Medical grade, platinum cured silicone |
Cadence Module Operating Limits | |
Maximum Pressure | 6 barg (87 psig) @ 23 °C 4.1 barg (60 psig) @ 55 °C |
Maximum Transmembrane Pressure (TMP) | 4.1 barg (60 psig) @ 4 - 55 °C |
Processing Temperature Range | 4 to 40 °C (freezing will damage module) |
pH Range | 2 to 13 |
Flow Rate Range During Cleaning | < 5 L/min/m2 (0.2 L/min/ft2) |
The performance of Cadence modules, based on an IgG model feed solution, is demonstrated in the table below over a wide range of feed flow rates (L/min/m2) and volumetric concentration factors (X) for various module configurations and feed concentrations (g/L).
Cadence Module Typical Feed Flow Rates in L/min/m2 | Concentration Factor | ||
Process Flux* | 4X | 10X | 30X |
10 LMH | 0.22 | 0.19 | 0.17 |
50 LMH | 1.11 | 0.93 | 0.86 |
100 LMH | 2.22 | 1.85 | 1.72 |
* LMH = Liters/meter2/hour
Cadence Module Integrity Test | |
Systems Integrity Test Pressure | 4.1 barg (60 psig) |
Acceptable Pressure Decay (System) | < 0.07 barg (1 psig) per minute |
Module Integrity Test Pressure | 4.1 barg (60 psig) |
Acceptable Forward Flow Rate | < 50 sccm/ft2 (538 sccm/m2) |
Each Cadence module has a unique serial number for full traceability.
Shelf Life
The shelf life of Cadence modules packaged in preservative is expected to be two years from the date of manufacture when the modules are stored unopened in the original packaging at ambient temperature up to 25 °C and protected from direct light. Extended shelf life studies are ongoing.
Biological Safety
Materials of construction for Cadence modules have been tested and meet the requirements for the Biological Reactivity Tests listed in the United States Pharmacopeia (USP) under USP <88> for Class VI - 70 °C Plastics.
Documentation
Each module is supplied with the following comprehensive documentation to ensure the Cadence module is operated successfully:
- Certificate of Quality
- Care and Use Procedures
- Material Safety Data Sheet for the module preservative
Contact your local Pall representative to obtain:
- Validation Guide
- Validation service for specific tests such as compatibility testing with your product fluid
- Training and technical support to optimize your process using Cadence systems
Pall Provides Comprehensive Documentation with Each Cadence Module
Applications
- In-process volume reduction
- Desalting protein solutions
- Purification and recovery of antibodies or recombinant proteins
- Preparation of samples (concentrating, desalting) before or after column chromatography
Single-Use Applications
Depending on the application, Cadence modules may also be applied for single use. When applied for single use, Cadence modules are used with a specially-designed Cadence system. Contact Pall for more information on single-use systems.
Application Note: Cadence™ Systems Employ New Single-Pass TFF Technology To Simplify Processes And Lower Costs- The commercialization of a revolutionary TFF technology by Pall Life Sciences presents opportunities to simplify biopharmaceutical process design and lower capital and operational costs. The new technology, single-pass TFF, is brought to life through Pall’s Cadence systems and modules. This Application Note introduces the design innovations of Cadence Single-Pass TFF Systems to biopharmaceutical researchers and manufacturers.
- SPTFF process is continuous, produces high concentration factors, significantly higher conversion in one pass through flow rating control and eliminates the need for the conventional recirculation loop.
- Elimination of the conventional recirculation loop minimizes aggregation problems and requires no mixing, minimizes shear exposure and also alows the SPTFF step to be coupled with other downstream process steps.
- Additional SPTFF benefits over conventional TFF include lower system hold-up volumes, higher recoveries, and lower flush volume requirements.
- Applications that can leverage SPTFF technology include but are not limited tin-process volume reduction, inline salt reduction, high-concentration formulations, and processing of fragile biomolecules.
Performance
Achieve High Concentration Factors:
Flux Versus Concentration for Cadence Modules with Delta 30 kD Membrane
MAb Material (53.2 g/L Initial Concentration)
Type
Use
Related Documents
Regulatory/Quality Documentation
Ordering Information
Identify
and order Cadence modules using the table below. For example, a Cadence T01 module with 10 kD Delta regenerated cellulose membrane area of 0.14 m2 (1.5 ft2) is part number CD010T010815. Note: a Pall Cadence system must be used to operate Cadence modules. (Contact Pall for information on a Cadence system to meet your application requirements.)
Guide to Cadence Module Part Numbers
Example: Part number CD010T010815
C | D | 010 | T01 | 08 | 15 |
Concentration | Delta membrane | Nominal molecular weight cutoff (10 kD) | Cassette format | Number of cassettes in series | Total number of cassettes in module |
Cadence Module | Configuration | Delta 10 kD Membrane Area (m2) | Part Number |
T01 | 4-in-series | 0.065 | CD 010 T010407 |
T01 | 7-in-series | 0.12 |
CD 010 T010713 |
T01 | 8-in-series | 0.14 | CD 010 T010815 |
T01 | 9-in-series | 0.17 |
CD 010 T010918 |
T02 | 4-in-series | 0.13 |
CD 010 T020407 |
T02 | 7-in-series | 0.24 |
CD 010 T020713 |
T02 | 8-in-series | 0.28 | CD 010 T020815 |
T02 | 9-in-series | 0.33 | CD 010 T020918 |
T12 | 4-in-series | 0.7 | CD 010 T120407 |
T12 | 7-in-series | 1.3 |
CD 010 T120713 |
T12 | 8-in-series | 1.5 |
CD 010 T120815 |
T12 | 9-in-series | 1.8 | CD 010 T120918 |
T06 | 4-in-series | 3.5 | CD 010 T060407 |
T06 | 7-in-series | 6.5 | CD 010 T060713 |
T06 | 8-in-series | 7.5 | CD 010 T060815 |
T06 | 9-in-series | 9.0 | CD 010 T060918 |
Cadence Module | Configuration | Delta 30 kD Membrane Area (m2) | Part Number |
T01 | 4-in-series | 0.065 | CD 030 T010407 |
T01 | 7-in-series | 0.12 |
CD 030 T010713 |
T01 | 8-in-series | 0.14 | CD 030 T010815 |
T01 | 9-in-series | 0.17 |
CD 030 T010918 |
T02 | 4-in-series | 0.13 |
CD 030 T020407 |
T02 | 7-in-series | 0.24 |
CD 030 T020713 |
T02 | 8-in-series | 0.28 | CD 030 T020815 |
T02 | 9-in-series | 0.33 | CD 030 T020918 |
T12 | 4-in-series | 0.7 | CD 030 T120407 |
T12 | 7-in-series | 1.3 |
CD 030 T120713 |
T12 | 8-in-series | 1.5 |
CD 030 T120815 |
T12 | 9-in-series | 1.8 | CD 030 T120918 |
T06 | 4-in-series | 3.5 | CD 030 T060407 |
T06 | 7-in-series | 6.5 | CD 030 T060713 |
T06 | 8-in-series | 7.5 | CD 030 T060815 |
T06 | 9-in-series | 9.0 | CD 030 T060918 |
Product Summary
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.