Centrifugal Filters

Pall’s centrifugal filter devices can accelerate sample processing, maximize sample recovery, add versatility and prevent solution bypass.

Accelerate sample processing – Concentrate and purify samples with starting volumes of < 50 µL to 60 mL.

Maximize sample recovery – Obtain high flow rates and low non-specific protein and nucleic acid binding.

Add versatility – Available in various membrane types; Nanosep®, Microsep®, Macrosep™, and Jumbosep™ devices are available with Omega™ (modified polyethersulfone) ultrafiltration membrane in a variety of MWCOs. Nanosep MF devices are available with low-binding Bio-Inert® (modified nylon) and wwPTFE (hydrophilic polytetrafluoroethylene) membranes. Microsep and Macrosep devices also are available with Supor® (polyethersulfone) membrane.

Prevent solution bypass – Membrane seals stop solution leakage, minimizing sample loss.

Easy visual identification – Devices are color-coded for a wide variety of membranes, ranging from 1k to 0.45 µm

Pall Centrifugal Filters

Product images are a representation of product family for illustartion purpose only. Actual products may vary

Length

12.80 cm

AcroPrep Advance Filter Plates for Aqueous Filtration - 1 mL, 30-40 µm PP/PE non-woven media (5/pkg)

Product ID: 8127
Unit of Measure
1/PAC
Min Order Qty
1
Filter Media
PP/PE non-woven (polypropylene/polyethylene) media
Pore Size Maximum
40 μm
Pore Size Minimum
30 μm
Sample Volume
< = 9 00 μL
Height (Metric cm)
1.8 cm
Length (Metric cm)
12.80 cm
See All Attributes
$ 169.00

AcroPrep Advance Filter Plates for Aqueous Filtration - 2 mL, 30-40 µm PP/PE non-woven media (5/pkg)

Product ID: 8227
Unit of Measure
1/PAC
Min Order Qty
1
Filter Media
PP/PE non-woven (polypropylene/polyethylene) media
Pore Size Maximum
40 μm
Pore Size Minimum
30 μm
Sample Volume
< = 1 .9 μL
Height (Metric cm)
1.8 cm
Length (Metric cm)
12.80 cm
See All Attributes
$ 169.00

AcroPrep™ Advance Filter Plate, 350 μL, 30-40 µm PP/PE non-woven media (10/pkg)

Product ID: 8027
Unit of Measure
1/PAC
Min Order Qty
1
Filter Media
PP/PE non-woven (polypropylene/polyethylene) media
Pore Size Maximum
40 μm
Pore Size Minimum
30 μm
Sample Volume
< = 1 .9 μL
Height (Metric cm)
1.8 cm
Length (Metric cm)
12.80 cm
See All Attributes
$ 282.00

Documents

Data Sheets

  • Centrifugal Devices

    Select Language :
  • Pall Nucleic Acid Binding Nanosep® Centrifugal Device

    Select Language :

Specifications

Nanosep® Centrifugal Filters
Materials of construction
Sample Reservoir, Membrane Support Base and Filtrate Receiver: Polypropylene Filter Media: Omega (modified polyethersulfone) ultrafiltration membrane Nanosep MF Devices Sample Reservoir, Membrane Support Base and Filtrate Receiver: Polypropylene Filter Media: wwPTFE (hydrophilic Polytetrafluoroethylene) and Bio-Inert (modified nylon) membranes
Nanosep® Centrifugal Filters
Effective filtration area
0.28 cm²
Nanosep® Centrifugal Filters
Dimensions
Length (full assembly with cap): 4.5 cm (1.8 in.)
Nanosep® Centrifugal Filters
Operating temperature range
0 – 40°C (32 – 104°F)
Nanosep® Centrifugal Filters
Capacities
Maximum Sample Volume: 500 μL Final Concentrate Volume: 15 μL Filtrate Receiver Volume: 500 μL Hold-up Volume (membrane/support): < 5 μL
Nanosep® Centrifugal Filters
pH range
1 – 14
Nanosep® Centrifugal Filters
Maximum centrifugal force
14,000 x g
Nanosep® Centrifugal Filters
Centrifuge
Fits centrifuges that accept 1.5 mL tubes
Nanosep® Centrifugal Filters
Sanitization
Non-sterile. May be sanitized by filtering 70% ethanol through the device before use.
Microsep™ Centrifugal Filters
Materials of construction
Sample Reservoir, Membrane Support Base and Filtrate Receiver: Polypropylene Filter Media: Supor (polyethersulfone) and Omega (modified polyethersulfone) membranes Paddle: Polyethylene
Microsep™ Centrifugal Filters
Effective filtration area
3.3 cm²
Microsep™ Centrifugal Filters
Dimensions
Length: 12.0 cm (4.9 in.) Diameter: 17 mm (0.7 in.)
Microsep™ Centrifugal Filters
Operating temperature range
0 – 40°C (32 – 104°F)
Microsep™ Centrifugal Filters
Capacities
Maximum Sample Volume: 5.0 mL Final Concentrate Volume: 65 μL (swinging bucket) 100 μL (35o angle rotor) 80 μL (45o angle rotor) Filtrate Receiver Volume: 6.5 mL Hold-up Volume: 40 μL (membrane and paddle)
Microsep™ Centrifugal Filters
pH range
1 – 14
Microsep™ Centrifugal Filters
Maximum centrifugal force
7,500 x g (for ultrafiltration)
Microsep™ Centrifugal Filters
Centrifuge
Fits rotors that work with standard 15 mL conical tubes and are capable of 3,000 to 14,000 x g
Microsep™ Centrifugal Filters
Sanitization
Non-sterile. May be sanitized by filtering 70% ethanol through the device before use.
Macrosep® Centrifugal Filters
Materials of construction
Sample Reservoir, Membrane Support Base and Filtrate Receiver: Polypropylene Filter Media: Supor (polyethersulfone) and Omega (modified polyethersulfone) membranes Paddle: Polyethylene
Macrosep® Centrifugal Filters
Effective filtration area
7.2 cm²
Macrosep® Centrifugal Filters
Dimensions
Length: 12.0 cm (4.7 in.) Diameter: 50 mm (1.9 in.)
Macrosep® Centrifugal Filters
Operating temperature range
0 – 40°C (32 – 104°F)
Macrosep® Centrifugal Filters
Capacities
Maximum Sample Volume: 20 mL Final Concentrate Volume: As low as 450 μL, depending on rotor used Filtrate Receiver Volume: 22 mL Hold-up Volume: 80 μL (membrane and paddle)
Macrosep® Centrifugal Filters
pH range
1 – 14
Macrosep® Centrifugal Filters
Maximum centrifugal force
5,000 x g (for ultrafiltration)
Macrosep® Centrifugal Filters
Centrifuge
Fits rotors that accept standard 50 mL conical end tubes
Macrosep® Centrifugal Filters
Sanitization
Non-sterile. May be sanitized by filtering 70% ethanol through the device before use.
Jumbosep™ Centrifugal Filters
Materials of construction
Sample Reservoir and Filtrate Receiver: Polysulfone Sample Reservoir Cap: Polyethylene Filter Media: Omega (modified polyethersulfone) membrane Insert Without Membrane: High-density polyethylene Filtrate Receiver Cap and Insert Release: Polypropylene
Jumbosep™ Centrifugal Filters
Effective filtration area
15.2 cm²
Jumbosep™ Centrifugal Filters
Dimensions
Maximum Outside Diameter: 6 cm (2.4 in.) Height (Full Assembly with Cap): 11.3 cm (4.5 in.)
Jumbosep™ Centrifugal Filters
Operating temperature range
0 – 40°C (32 – 104°F)
Jumbosep™ Centrifugal Filters
Capacities
Maximum Sample Volume: 60 mL Final Concentrate Volume: 3.5 – 4 mL Filtrate Receiver Volume (Maximum): 60 mL Hold-up Volume: 0.2 mL (membrane/support)
Jumbosep™ Centrifugal Filters
pH range
1 – 14
Jumbosep™ Centrifugal Filters
Maximum centrifugal force
3,000 x g
Jumbosep™ Centrifugal Filters
Centrifuge
Fits swinging bucket rotors that accept flat-bottomed 250 mL bottles and are capable of 1,000 to 3,000 x g
Jumbosep™ Centrifugal Filters
Sanitization
Non-sterile. May be sanitized by filtering 70% ethanol through the device before use. The filtrate receiver and sample reservoir can be autoclaved. Do not autoclave the filter media.

Applications

Pall’s centrifugal filter devices can replace traditional separation techniques, such as column chromatography, preparative electrophoresis, alcohol or salt precipitation, dialysis, and gradient centrifugation, when performing the following: Protein or nucleic acid concentration Desalting Buffer exchange Deproteination of biological samples Fractionation of protein mixtures Separation of primers from PCR products Separation of labeled nucleic acids or proteins from unincorporated nucleotides Virus concentration or removal Clarification of cell lysates and tissue homogenates