Operating Conditions
Operating temperature and maximum differential pressures in compatible fluids.1
Operating Temperature |
Maximum Differential Pressure |
82 °C / 180 °F |
1 bard / 15 psid |
70 °C / 158 °F |
2 bard / 30 psid |
30 °C / 86 °F2 |
4.1 bard / 60 psid |
1 Fluids that do not soften, swell or adversely affect the filter or materials of construction.
2 Recommended filter changeout: 2.3 bard / 40 psi.
Typical Liquid Flow Rate versus Differential Pressure3
3 For liquids with viscosities differing from water, multiply the pressure drop by the viscosity in cP.
Figure 1 Graded pore structure