Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

AB4P01018J

Product ID: AB4P01018J
Unit of Measure
12/EA
Min Order Qty
12

Filter 40" Profile II 5µm

Product ID: AB4Y05018J
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

Filter 40" Profile II 0,5µm product photo

Filter 40" Profile II 0,5µm

Product ID: AB4Y0057J
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

AB4Y10018H

Product ID: AB4Y10018H
Unit of Measure
12/EA
Min Order Qty
24

AB4Y03018J

Product ID: AB4Y03018J
Unit of Measure
12/EA
Min Order Qty
12

CRTG AB4Y0308J

Product ID: AB4Y0308J
Unit of Measure
12/EA
Min Order Qty
12

AB4Y10018J

Product ID: AB4Y10018J
Unit of Measure
12/EA
Min Order Qty
12

AB4Y30018J

Product ID: AB4Y30018J
Unit of Measure
12/EA
Min Order Qty
12

Profile® II, Filter Cartridges, Polypropylene, Length 30 Inches, Fluorocarbon Elastomer

Product ID: AB3Y40018H
Unit of Measure
24/EA
Min Order Qty
24
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
753 mm
Cartridge Length (Metric)
75.3 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
Cartridge Outer Diameter (OD) (Imperial)
2.75 in
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 Inches

Product ID: ARD0530USM3
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.5 µm
End Configuration
SOE flat closed end, external 222 O-rings
Change Out Differential Pressure
2.4 bard

Poly-Fine® ARD, Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 Inches, EPDM

Product ID: ARD0520UEDOE
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 10 Inches

Product ID: ARD1010UH21
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
End Configuration Code
H21
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :