Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

DISC NM NPG 025100 product photo

DISC NM NPG 025100

Product ID: NPG025100
Unit of Measure
1/BOX
Min Order Qty
1
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, Nitrile product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, Nitrile

Product ID: NXA0510UM3N
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, FEP encapsulated fluorocarbon elastomer Orings

Product ID: NXA0510UM3F
Unit of Measure
30/EA
Min Order Qty
30
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
FEP encapsulated fluorocarbon elastomer (O-rings)
See All Attributes
NXA 0.5-10U-M7S product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), SOE fin end, external 226 O-rings (retrofits other manufacturers’ Code 7), Silicone gasket

Product ID: NXA0510UM7S
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 19.5 inches

Product ID: NXA05195UH21
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
19.5 in
Cartridge Length (Metric)
495 mm
Cartridge Length (Metric)
49.5 cm
Gasket / O-Ring Material
NA
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, silicone product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches, silicone

Product ID: NXA0510UM3S
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene

Product ID: NXA051UH21
Unit of Measure
6/EA
Min Order Qty
6
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
NA
End Configuration Code
H21
End Configuration
H21 - DOE, Santoprene gasket seal
Cartridge Type
NXA
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 10 inches

Product ID: NXA0510U
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.5 micron
NXA 0.5-10U-DOEE product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), DOE with elastomer gasket seals and end caps, EPDM gasket

Product ID: NXA0510UDOEE
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.5 micron
NXA 0.5-10U-M3E product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), EPDM gasket

Product ID: NXA0510UM3E
Unit of Measure
60/EA
Min Order Qty
60
Micron
0.5 micron
NXA 0.5-20U-DOEE product photo

Nexis, NXA, 0.5 μm, 50.8 cm (20 in), DOE with elastomer gasket seals and end caps, EPDM gasket

Product ID: NXA0520UDOEE
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 inches, Fluorocarbon Elastomer, SOE flat closed end external 222 O-rings product photo
Unit of Measure
24/EA
Min Order Qty
24
Micron
0.5 micron

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :