Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

CTRG BW HDC H400 C7 (4-HIGH) product photo

CTRG BW HDC H400 C7 (4-HIGH)

Product ID: BWAB4P400XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

CTRG BW HDC HS-40 C7 40" product photo

CTRG BW HDC HS-40 C7 40

Product ID: BWAB4P1000XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

CTRG BW HDC H050 C7 H 3H product photo

CTRG BW HDC H050 C7 H 3H

Product ID: BWAB3P050XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 304 stainless steel product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 304 stainless steel

Product ID: C001A10A
Unit of Measure
30/EA
Min Order Qty
30
Packaging
Bulk
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 316 stainless steel, Bulk packaging product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 316 stainless steel, Bulk packaging

Product ID: C001A10S
Unit of Measure
30/EA
Min Order Qty
30
Packaging
Bulk
See All Attributes
C001A975A product photo

C001A9.75A

Product ID: C001A975A
Unit of Measure
30/EA
Min Order Qty
30
C001AW20U product photo

C001AW20U

Product ID: C001AW20U
Unit of Measure
1/EA
Min Order Qty
1
Packaging
Bulk
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 316 stainless steel, with Core Cover product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, 316 stainless steel, with Core Cover

Product ID: C001A10SC
Unit of Measure
30/EA
Min Order Qty
30
Packaging
Bulk
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, Electrolytic tin plated steel product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 10 Inches, Electrolytic tin plated steel

Product ID: C001A10T
Unit of Measure
30/EA
Min Order Qty
30
Packaging
Bulk
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 29.5 Inches, 316 stainless steel, Bulk packaging product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 29.5 Inches, 316 stainless steel, Bulk packaging

Product ID: C001AW295S
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, 304 stainless steel, with Core Cover

Product ID: C001AW20AC
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
1 µm
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Cartridge Outer Diameter (OD) (Imperial)
2.5 in
Cartridge Outer Diameter (OD) (Metric)
6.4 cm
See All Attributes
DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, Electrolytic tin plated steel product photo

DFT Classic®, Filter Cartridges, Removal Rating 1 μm, Length 20 Inches, Electrolytic tin plated steel

Product ID: C001AW20T
Unit of Measure
10/EA
Min Order Qty
10
Packaging
Bulk
See All Attributes

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.

Documents

Data Sheets

  • Profile® II RFN Series Filter Elements

    Select Language :