Profile® II RFN Nylon Depth Filter – Gas, Liquid Filter Cartridges

For Liquid and Gas Applications 

Profile II RFN Series depth filter cartridges are for liquid and gas applications such as chemical, petrochemical, paint, resin coating, and food and beverage. They are comprised of an all-nylon filter medium with glass-filled polypropylene cores and available with glass-filled nylon cores for use with xylene, toluene, or other aromatics and high temperatures.  There is no binder resin as the fibers are “bonded” by intertwining during the manufacturing process.  As a result, these depth filter cartridges show no media migration.

Order Products

Product Use

Pre-Filtration

Poly-Fine® II, Filter Cartridges, Removal Rating 0.1 μm, Polypropylene, Length 10 Inches, Nitrile product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.1 μm, Polypropylene, Length 10 Inches, Nitrile

Product ID: PFT0110UN959
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.1 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.1 μm, Polypropylene, Length 10 Inches, Fluorocarbon Elastomer product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.1 μm, Polypropylene, Length 10 Inches, Fluorocarbon Elastomer

Product ID: PFT0110UVM3958
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.1 µm
PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3 product photo

PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3

Product ID: PFT0210UEM3513
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, DOE industrial product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, DOE industrial

Product ID: PFT0210UE
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3 product photo

PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM, M3

Product ID: PFT0210UEM3BLK513
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM product photo

PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, EPDM

Product ID: PFT0210UEBLK794
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, SOE flat closed end external 222 O-rings product photo
Unit of Measure
30/EA
Min Order Qty
30
Micron
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, SOE fin end external 222 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, SOE fin end external 226 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, Nitrile, DOE industrial 2.54 cm (1 in) extended core product photo
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm
PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, Nitrile (standard gaskets) product photo

PolyFine-II Filter Cartridge, Highly asymmetric polysulfone, 0.2 µm, 10 in, Nitrile (standard gaskets)

Product ID: PFT0210UNBBLK
Unit of Measure
1/EA
Min Order Qty
1
Micron
0.2 µm

Description

Why Choose Profile II RFN Series depth filter cartridges?

 

The Profile II RFN elements have an absolute rated downstream section leading to 99.98% efficiency in liquid and a continuously profiled pore size upstream section for increased service life. 

Product Highlights

  • All nylon filter medium with glass-filled polypropylene cores
  • Increased service life

Applications/Uses

The Profile II RFN filter has numerous applications in a broad range of industries such as chemical, petrochemical, pharmaceutical, paint, resin coating, food, beverage and cosmetics.

 

 

Chemicals and Polymer:

  • Chemicals - Final product (liquid), raw material (gas, air, liquid) and intermediate product (other)
  • Petrochemicals (Amine, Benfield, other solvent loops)
  • Polymer - Carbon fiber, nylon and polyurethane production

Oil and Gas:

  • Upstream Injection Water & SRU
  • Midstream LNG acid gas
  • Midstream glycol filtration
  • Midstream Process Water
  • Refinery Amine Systems

Specifications

 

The recommended maximum pressure differential for the standard RFN Series filters is 75 psi up to 86 °F (30 °C), 50 psi up to 158 °F (70 °C), and 35 psi up to 180 °F (82 °C). For the GN Series filters with glass filled nylon cores, recommended maximum pressure differential is 90 psi up to 86 °F (30 °C), 80 psi up to 158 °F (70 °C), 70 psi up to 212 °F (100 °C), and 50 psi up to 300 °F (150 °C).

 

If the fluid filtered is compatible with polypropylene and temperature below 194 °F (90 °C), Profile II RF Polypropylene Series elements, described in Data Sheet E1 and Bulletin PRO 400, may be suitable. Pall Corporation’s Scientific and Laboratory Services group will supply compatibility information for both nylon and polypropylene upon request.

 

Cartridge Grade Grade Removal Rating Clean Pressure Drop Typical Aqueous Flow (GPM/10" Cartridge)
  Liquid Service Liquid Service Gaseous Service  
  Rating in μm at % Efficiency Aqueous Pressure Drop (psi/gpm)2 CFM of Air per PSI per 10" Cartridge3  
  90% 99% 99.9% 99.98%      
050 2.0 3.0 4 5 0.8 11 3 - 8
100 6.5 7.5 9 10 0.3 29 6 - 15
200 10 14 18 20 0.10 75 10 - 15
400  20 30 35 40 0.05 207 10 - 15
700 32 50 701 - <0.05 415 10 - 15

 

1 Extrapolated values.

2 Pressure drop in PSI per GPM for a single 10″ module. For multiple elements, divide by number of modules. For fluids other than water, multiply by viscosity in centipoise.

3 For longer modules, increase the flow rates listed in proportion. The flow rates listed do not take into account pressure losses due to flow in the internal diameter of the element, which becomes significant above about 40 to 60 cfm.