Order Products
Element Series
HCY090
Red1000 Glass Fiber 3 micron (Beta 1000) Fluorocarbon 41in 104.14cm (REPLACED BY HCY09003FRZ41Z)
1/EA
1
This product is currently not available. Please contact us for more information.
High-Performance Pleated Depth Filters for Particle Removal in Food and Beverage Applications
The PREcart PP II conventional, fan pleated depth filter cartridge is ideal for applications requiring excellent particle removal while effectively prolonging the life of downstream final filters. The highly stable media structure also offers consistent and excellent filtrate quality.
Element Series
HCY090
This product is currently not available. Please contact us for more information.
Why choose PREcart PP II pleated depth filter cartridges?
These cartridges are designed to meet typical food and beverage production cycles' high mechanical resistance and compatibility requirements including filtration, sanitization, regeneration, and steam sterilization.
Additional benefits include:
Quality
Food Contact Compliance
Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.
Technical Information
The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described unless otherwise indicated. Actual operating conditions may affect the filter's performance.
PERFORMANCE
Operating Characteristics in Compatible Fluids1
Maximum Differential Pressure | Operating Temperature |
---|---|
5.0 bard (72.5 psid) (forward) | 25 °C (77 °F) |
2.0 bard (29 psid) (forward) | 80 °C (176 °F) |
1.5 bard (21.8 psid) (forward) | 90 °C (194 °F) |
1 bard (14.5 psid) (reverse) | 60 °C (140 °F) |
1Fluids which do not swell, soften, or adversely affect any of the filter components.
Table 1: Removal Rating2
Code | Description |
---|---|
110 | 1 µm |
120 | 2 µm |
130 | 3 µm |
150 | 5 µm |
210 | 10 µm |
220 | 20 µm |
2PREcart PP filter cartridge liquid retention ratings are based on a modified OSU-F2 single pass test. The removal efficiency for all grades is 99.98%.