PTFE Syringe Filters

Pall non-sterile syringe filters with PTFE membrane are ideal for use in the filtration of gas or organic solvents. PTFE syringe filters have been widely used for the sample preparation applications, removing particulate contamination and protecting HPLC systems and columns.

Order Products

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 30in 76.2cm

Product ID: HC2286FKS30H
Unit of Measure
1/EA
Min Order Qty
6
Anti-Static
No
Beta Rating
BETA 1000
Element Series
HC2286
Family
Red1000
Filter Media
Glass Fiber
Filter Removal Rating (μm)
12 µm
See All Attributes
RT250A10S product photo

RT250A10S

Product ID: RT250A10S
Unit of Measure
1/EA
Min Order Qty
1
Packaging
Bulk
See All Attributes

BR 25-20 246

Product ID: BR2520246
Unit of Measure
18/EA
Min Order Qty
18

FluoroTrans W PVDF Transfer Membrane - 7 x 9 cm sheets (10/pkg)

Product ID: BSP0158
Unit of Measure
1/PAC
Min Order Qty
1
Detection System
Chemiluminescence|Total Protein
Filter Media
Fluoro Trans PVDF
Pore Size (Removal Rating)
0.2 µm
Sheet Size Length (Metric cm)
7 cm
Sheet Size Width (Metric cm)
9 cm
Typical Thickness (Metric µm)
127 µm
See All Attributes
125MM (4.92") SLIT .2UM PVDF product photo

125MM (4.92") SLIT .2UM PVDF

Product ID: BSP0440
Unit of Measure
1/FT
Min Order Qty
1

FluoroTrans W PVDF Transfer Membrane - 10 x 15 cm sheets (10/pkg)

Product ID: BSP0157
Unit of Measure
1/PAC
Min Order Qty
1
Detection System
Total Protein|Chemiluminescence
Filter Media
Fluoro Trans PVDF
Pore Size (Removal Rating)
0.2 µm
Sheet Size Length (Metric cm)
10 cm
Sheet Size Width (Metric cm)
15 cm
Typical Thickness (Metric µm)
127 µm
See All Attributes

FluoroTrans W PVDF Transfer Membrane - 20 x 20 cm sheets (10/pkg)

Product ID: BSP0159
Unit of Measure
1/PAC
Min Order Qty
1
Detection System
Chemiluminescence|Total Protein
Filter Media
Fluoro Trans PVDF
Pore Size (Removal Rating)
0.2 µm
Sheet Size Length (Metric cm)
20 cm
Sheet Size Width (Metric cm)
20 cm
Typical Thickness (Metric µm)
127 µm
See All Attributes

FluoroTrans W PVDF Transfer Membrane - 26 cm x 3.3 m roll (1/pkg)

Product ID: BSP0161
Unit of Measure
1/EA
Min Order Qty
1
Detection System
Chemiluminescence|Total Protein
Filter Media
Fluoro Trans PVDF
Pore Size (Removal Rating)
0.2 µm
Roll Size Length (Metric cm)
26 cm
Roll Size Width (Metric m)
3.3 m
Typical Thickness (Metric µm)
127 µm
See All Attributes

BT839

Product ID: BT839
Unit of Measure
1/EA
Min Order Qty
1
CTRG BW HDC H050 C7 H 3H product photo

CTRG BW HDC H050 C7 H 3H

Product ID: BWAB3P050XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

CTRG BW HDC H400 C7 (4-HIGH) product photo

CTRG BW HDC H400 C7 (4-HIGH)

Product ID: BWAB4P400XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

CTRG BW HDC HS-40 C7 40" product photo

CTRG BW HDC HS-40 C7 40

Product ID: BWAB4P1000XHS
Unit of Measure
1/EA
Min Order Qty
1

This product is currently not available. Please contact us for more information.

Description

Syringe filters are used in analytical chemistry applications to remove particulate contamination prior to analysis. Filtering a sample prior to injection into a HPLC machine will help protect sensitive parts of the instrument from particulate build up and reduce system downtime. 

 

Sample filtration using syringe filters containing 0.45 μm (HPLC) or 0.2 μm (UHPLC) pore size membranes will also extend the life of chromatography columns. High performance columns are composed of small particles of narrow size distribution. Optimal peak profiles depend on column operating characteristics and should be instrument independent. Filtration can prevent particulate contamination of a column, and avoid physical changes occurring such as blocked frits or channel voids in the column packing.

 

The use of PTFE syringe filters in analytical chemistry sample preparation has long been established. The membrane is highly chemically compatible for the filtration of harsh solvents that can destroy other membrane materials. PTFE is a hydrophobic membrane, so it will repel water and is not suitable for the filtration of aqueous solutions. However, newer analytical chemistry syringe filter technology such as Pall’s Acrodisc® syringe filters with wwPTFE membrane are now available, they contain a special water wettable PTFE membrane that can be considered as universally compatible as it can be used in both aqueous and organic applications.

 

As well as being suitable for the filtration of organic solvents in applications such as HPLC and UHPLC sample preparation, the hydrophobic nature of the PTFE membrane makes these syringe filters ideal to use in gas filtration or as a moisture barrier in venting applications.

Pall supplies PTFE syringe filters in different formats. The devices are all constructed from chemically compatible polypropylene. A 4 mm syringe filter is ideal for small sample volumes of up to 2 mL. They offer a very low sample hold up of < 10 μl. The 13 mm syringe filters are designed for the filtration of volumes up to 10 mL. 13 mm filters are available with a standard male slip luer outlet or Pall’s proprietary minispike outlet. The minispike allows for easy handling with a HPLC vial, and also offers a reduced hold-up volume, ensuring maximum filtrate recovery. 

 

Typical hold-up volumes:

  • 4 mm: < 10 μl
  • 13 mm, male slip luer outlet: < 30 μl 
  • 13 mm, minispike: < 14 μl

Pall supplies both traditional ring moulded 25 mm PTFE syringe filters and PSF (Premium Syringe Filter) 25 mm PTFE syringe filters. The PSF syringe filter has larger effective filtration area compared with the older traditional model, 3.9 cm2 compared to 2.8 cm2. This gives the PSF syringe filter a much improved throughput and flow rate.

PTFE PSF syringe filters are available with a multi-layered glass fiber prefilter (GxF) above the PTFE membrane. Syringe filters with the GxF configuration prefilter provide two to four times the throughput of standard prefilter devices for particulate-laden samples. This makes the filter ideal for applications in which there could be a high particulate load in the sample.

The 25 mm PSF filters have been designed and certified to meet the exacting requirements of automation systems. They demonstrate critical criteria including smooth filter-to-filter release, consistent turret advancement, exceptional housing strength and a strict outside filter geometry to ensure proper alignment and consistent operation. AutopackTM tube packaging is available for compatible automated equipment.

Pall Life Sciences HPLC certification ensures that analytical results will not be compromised by extractable filter materials. To verify low levels of UV-detectable extractables, samples of the HPLC Acrodisc syringe filter line are randomly taken and tested for compatibility with common HPLC solvents using standard HPLC conditions.

Document

Datasheet

  • Tech Guide: Acrodisc Syringe Filters for Analytical Sample Preparation

    Select Language :

Applications

  • Ideal for filtration of gas and/or organic solvents 
  • HPLC/UHPLC sample preparation
  • Moisture barrier for venting applications

Specifications

Product Specifications Values

PTFE Syringe Filters

Materials of Construction

Filter Media: Hydrophobic PTFE

membrane on a polypropylene

support

Housing: Polypropylene

GxF Prefilter: Borosilicate glass

Pore Size

PTFE Membrane: 0.2 and 0.45 μm

GxF Prefilter: 40 - 1 μm

Effective Filtration Area

4 mm: 0.2 cm2

13 mm: 1.0 cm2

25 mm PSF: 3.9 cm2

Inlet/Outlet Connections

4, 13, and 25 mm PSF: Female luer

lock inlet, male slip luer outlet

13 mm: Available with minispike outlet

Maximum Operating Pressure

 4 mm: 5.2 bar (520 kPa, 75 psi)

13 mm: 6.9 bar (690 kPa,100 psi)

25 mm PSF: 4.1 bar (410 kPa, 60 psi)

at 21 - 24 ºC (70 - 75 ºF);

2.1 bar (210 kPa, 30 psi) at 100 ºC

(212 ºF)

Typical Liquid Flow Rate (MeOH)

mL/min at 1.0 bar (100 kPa, 15 psi)

25 mm PSF, 0.2 μm: 245

25 mm PSF, 0.45 μm: 510

25 mm PSF, GxF/0.2 μm: NA

25 mm PSF, GxF/0.45 μm: 395