Acrylic Copolymer Syringe Filters

Sterile Acrodisc® syringe filters with Versapor® (acrylic copolymer) membrane are certified non-pyrogenic and biologically safe. These sterile filters can be used to filter aqueous samples and are ideal for use in the prefiltration of particulate laden samples, clarification of biological solutions and serum filtration.
Life Science Acrodisc Syringe Filters

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Product Use

Sterile Filtration and Clarification

Palltronic® Red Pneumatic Tubing (2m) with Stäubli fittings, CT001-INTUBING

Product ID: CT001-INTUBING
Unit of Measure
1/EA
Min Order Qty
1
Connections
Staubli Nipple
Length (m)
2 m

Palltronic® Blue Pneumatic Tubing (3m) with Stäubli fittings and vent valve (connects Compact Touch to test housing)

Product ID: CT001-OUTTUBING
Unit of Measure
1/EA
Min Order Qty
1
Connections
Staubli Coupling
Length (m)
3 m

Palltronic® Compact Touch External Power Supply, CT001-EXTPWR

Product ID: CT001-EXTPWR
Unit of Measure
1/EA
Min Order Qty
1
Adapter Info
Includes EU, UK, US, AU adaptors

Palltronic® Compact Touch Thermal Printer Paper, CT001-PRTPAPER

Product ID: CT001-PRTPAPER
Unit of Measure
1/EA
Min Order Qty
1
Paper
Thermal
Paper Roll Diameter
45 mm
Paper Roll Length
25 m
Paper Roll Width
58 mm

MicroFunnel™ Filter Funnel with Polycarbonate Membrane, 300 mL, 0.4 µm, Sterile, Individually Bagged (20/pkg)

Product ID: FMFNL3020
Unit of Measure
1/EA
Min Order Qty
1
Cover Material
Polystyrene
Cylinder and Base Material
Polypropylene
Diameter (Imperial in)
3.5 in
Diameter (Metric cm)
8.8 cm
Dimensions (Metric cm)
8.8 cm
EFA (Effective Filtration Area)
13.46 cm²
See All Attributes

MicroFunnel™ Filter Funnel with Polycarbonate Membrane, 100 mL, 0.4 µm, Sterile, Individually Bagged (50/pkg)

Product ID: FMFNL1050
Unit of Measure
1/PAC
Min Order Qty
1
Cover Material
Polystyrene
Cylinder and Base Material
Polypropylene
Diameter (Imperial in)
2.4 in
Diameter (Metric cm)
6.1 cm
EFA (Effective Filtration Area)
13.46 cm²
Filter Media
Polycarbonate Track-etched
See All Attributes

Glass filter funnel with sidearm support assembly and flask, 300 mL funnel with 1 L flask (1/pkg)

Product ID: 4013
Unit of Measure
1/EA
Min Order Qty
1
EFA (Effective Filtration Area)
9.6 cm²
Filter Size
47 mm

Glass filter funnel with sidearm support assembly and flask, 1 L funnel with 4 L flask (1/pkg)

Product ID: 4012
Unit of Measure
1/EA
Min Order Qty
1
EFA (Effective Filtration Area)
9.6 cm²
Filter Size
47 mm

Glass flask, 4 L (1/pkg)

Product ID: 4016
Unit of Measure
1/EA
Min Order Qty
1
EFA (Effective Filtration Area)
9.6 cm²
Filter Size
47 mm

Glass flask, 1 L (1/pkg)

Product ID: 4018
Unit of Measure
1/EA
Min Order Qty
1
EFA (Effective Filtration Area)
9.6 cm²
Filter Size
47 mm

SolVac® Filter Holder - Membrane seal gasket kit (10/pkg)

Product ID: 4025
Unit of Measure
1/PAC
Min Order Qty
1
EFA (Effective Filtration Area)
10.2 cm²
Filter Size
47 mm
Maximum Operating Temperature (Metric)
38 °C
Maximum Vacuum (Imperial)
25 in Hg

SolVac® Filter Holder - 122 cm (4 ft.) replacement feedline tubing (1/pkg)

Product ID: 4022
Unit of Measure
1/EA
Min Order Qty
1
EFA (Effective Filtration Area)
10.2 cm²
Filter Size
47 mm
Maximum Operating Temperature (Metric)
38 °C
Maximum Vacuum (Imperial)
25 in Hg

Description

Pall’s Versapor membrane is formed from an acrylic copolymer material, a membrane that is very strong and flexible providing excellent throughput with high liquid flow rates at low differential pressures. When the Versapor membrane is used in a syringe filter format it forms a single use, self contained, filtration device which is ideal for use in the filtration of particulate laden aqueous samples.

Acrodisc syringe filters with Versapor membrane are available sterilized by gamma irradiation. Sterilization by gamma irradiation eliminates potential cytotoxic residuals associated with EtO sterilization. They are individually blister packed to ensure sterility during storage and handling. The syringe filters are certified non-pyrogenic and biologically safe, making them ideal to use in life science applications such as the filtration of serum or the clarification of other biological solutions.

Documents

Applications

  • Prefiltration of particulate laden samples
  • Clarification of aqueous samples
  • Serum filtration

Specifications

Product Specifications Values

Acrodisc® Syringe Filters With Versapor® Membrane

 

Materials of Construction

Filter Media: Versapor membrane

(acrylic copolymer on a non-woven

support) 

25 mm Housing: Modified acrylic

Effective Filtration Area

25 mm: 2.8 cm2

Inlet/Outlet Connections

25 mm: Female luer lock

inlet, male slip luer outlet

Typical Hold-Up Volume

(with air purge)

25 mm: < 50 μL

Maximum Operating Temperature

25 mm: 55 °C (131 °F)

Maximum Operating Pressure

25 mm: 5.2 bar

(520 kPa, 75 psi)

 

Typical Water Flow Rate

mL/min at 3.1 bar (310 kPa, 45 psi) 

0.8 μm, 25 mm: 600

1.2 μm, 25 mm: 660

5 μm, 25 mm: 970

Endotoxin Level

< 0.25 EU/mL using Limulus

Amoebocyte Lysate (LAL) test

Biological Safety

Passes United States Pharmacopeia

(USP) Biological Reactivity Test,

In Vivo <88>

Sterilization

sterilized by gamma irradiation and individually blister packaged