Acrylic Copolymer Syringe Filters

Sterile Acrodisc® syringe filters with Versapor® (acrylic copolymer) membrane are certified non-pyrogenic and biologically safe. These sterile filters can be used to filter aqueous samples and are ideal for use in the prefiltration of particulate laden samples, clarification of biological solutions and serum filtration.
Life Science Acrodisc Syringe Filters

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Effective Filtration Area

5.8 cm²

Acrodisc® Syringe Filter with Supor® Membrane - 0.45 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4653
Unit of Measure
1/CV
Min Order Qty
1
Pore Size
0.45 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Acrodisc® Syringe Filters with Supor® Membrane, Sterile - 0.1 µm, 32 mm (50/pkg)

Product ID: 4651
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
0.1 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Membrane Material
Supor (Hydrophilic polyethersulfone)
Quantity
50 pkg
Sterile
Sterile
See All Attributes

Acrodisc® Syringe Filter with Supor® Membrane - 0.2 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4655
Unit of Measure
1/CV
Min Order Qty
1
Pore Size
0.2 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Acrodisc® Syringe Filter with Supor® Membrane - 1.2/0.45 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4661
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
1.2/0.45 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Acrodisc® Syringe Filter with Supor® Membrane - 5 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4662
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
5 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Acrodisc® Syringe Filter with Supor® Membrane - 0.8/0.2 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4659
Unit of Measure
1/CV
Min Order Qty
1
Pore Size
0.8/0.2 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Acrodisc® PF Syringe Filters with Supor® Membrane, Sterile - 0.8/0.2 µm, 32 mm (50/pkg)

Product ID: 4658
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
0.8/0.2 µm µm nominal
Filter Size
32 mm
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Hold-Up Volume
<100ul
Housing Material
Acrylic
See All Attributes

Acrodisc® Syringe Filters with Supor® Membrane, Sterile - 0.2 µm, 32 mm (50/pkg)

Product ID: 4652
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
0.2 µm µm nominal
Filter Size
32 mm
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Housing Material
Modified acrylic
Maximum Operating Pressure (bar)
5.2 bar
See All Attributes

Acrodisc® Syringe Filters with Supor® Membrane, Sterile - 0.45 µm, 32 mm (50/pkg)

Product ID: 4654
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
0.45 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Membrane Material
Supor (Hydrophilic polyethersulfone)
Quantity
50 pkg
Sterile
Sterile
See All Attributes

Acrodisc® Syringe Filters with Supor® Membrane, Sterile - 5 µm, 32 mm (50/pkg)

Product ID: 4650
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
5 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Membrane Material
Supor (Hydrophilic polyethersulfone)
Quantity
50 pkg
Sterile
Sterile
See All Attributes

Acrodisc® Syringe Filters with Supor® Membrane, Sterile - 1.2 µm, 32 mm (50/pkg)

Product ID: 4656
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
1.2 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Membrane Material
Supor (Hydrophilic polyethersulfone)
Quantity
50 pkg
Sterile
Sterile
See All Attributes

Acrodisc® Syringe Filter with Supor® Membrane - 1.2 µm, 32 mm modified acrylic housing (1000/pkg)

Product ID: 4660
Unit of Measure
1/PAC
Min Order Qty
1
Pore Size
1.2 µm µm nominal
Diameter (Metric)
32 mm
Effective Filtration Area (Metric)
5.8 cm²
Filter Media
Polyethersulfone (PES)
Hold-Up Volume
<100 µL
Housing Material
Acrylic
See All Attributes

Description

Pall’s Versapor membrane is formed from an acrylic copolymer material, a membrane that is very strong and flexible providing excellent throughput with high liquid flow rates at low differential pressures. When the Versapor membrane is used in a syringe filter format it forms a single use, self contained, filtration device which is ideal for use in the filtration of particulate laden aqueous samples.

Acrodisc syringe filters with Versapor membrane are available sterilized by gamma irradiation. Sterilization by gamma irradiation eliminates potential cytotoxic residuals associated with EtO sterilization. They are individually blister packed to ensure sterility during storage and handling. The syringe filters are certified non-pyrogenic and biologically safe, making them ideal to use in life science applications such as the filtration of serum or the clarification of other biological solutions.

Documents

Applications

  • Prefiltration of particulate laden samples
  • Clarification of aqueous samples
  • Serum filtration

Specifications

Product Specifications Values

Acrodisc® Syringe Filters With Versapor® Membrane

 

Materials of Construction

Filter Media: Versapor membrane

(acrylic copolymer on a non-woven

support) 

25 mm Housing: Modified acrylic

Effective Filtration Area

25 mm: 2.8 cm2

Inlet/Outlet Connections

25 mm: Female luer lock

inlet, male slip luer outlet

Typical Hold-Up Volume

(with air purge)

25 mm: < 50 μL

Maximum Operating Temperature

25 mm: 55 °C (131 °F)

Maximum Operating Pressure

25 mm: 5.2 bar

(520 kPa, 75 psi)

 

Typical Water Flow Rate

mL/min at 3.1 bar (310 kPa, 45 psi) 

0.8 μm, 25 mm: 600

1.2 μm, 25 mm: 660

5 μm, 25 mm: 970

Endotoxin Level

< 0.25 EU/mL using Limulus

Amoebocyte Lysate (LAL) test

Biological Safety

Passes United States Pharmacopeia

(USP) Biological Reactivity Test,

In Vivo <88>

Sterilization

sterilized by gamma irradiation and individually blister packaged