Product image is a representative example for illustration purposes. Actual product may vary.
AcroPak™ 1000 Capsules with Supor Membrane - 0.8/0.2 µm, gamma-irradiated (1/pkg)
Product ID: 12992 Need this product with different specifications
Membrane Material
Supor (Hydrophilic polyethersulfone)
Effective Filtration Area (Metric)
1000 cm²
Removal Rating
0.8/0.2 µm
Inlet/Outlet Connections
Stepped Hose Barb
Packaging Quantity
1 pkg
Sterile
Sterile
Documents
Datasheets
Download:Description
AcroPak 1000 Capsules with Supor Membrane, Sterile Filtration, 0.8/0.2 µm gamma-irradiated (1/pkg)
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."
“Pall Laboratory products are designed for laboratory applications only. This product is not approved for use in medical, clinical, surgical or other patient applications. If you require further assistance in product selection for your chosen application, please email us a question or call 1-800-521-1520."
Specifications
Materials of Construction
- Filter Media: Supor [hydrophilic polyethersulfone (PES)] membrane
- Housing, Vent Plug, and Filter Support: Polypropylene
- Sealing Technology: Thermal bonding
- Filling Bell: Polycarbonate
Pore Size
- 0.1/0.1, 0.2/0.2, 0.8/0.2, and 0.8/0.45 μm
Effective Filtration Area
- 500 Series: 500 cm2
- 1000 Series: 1000 cm2
- 1500 Series: 1500 cm2
Dimensions
- Housing Diameter: 6.9 cm (2.7 in.)
- Overall Length (Without Filling Bell):
500 Series: 14.5 cm (5.7 in.)
1000 Series: 19.3 cm (7.6 in.)
1500 Series: 22.9 cm (9.0 in.)
Inlet/Outlet Connections
- 500 and 1000 Series: 6.4 - 12.7 mm (1/4 - 1/2 in.) stepped hose barb with filling bell on outlet
- 1500 Series: 12.7 mm (1/2 in.) straight hose barb, no filling bell on outlet
Typical Hold-Up Volume (with 10 psi air purge)
- 500 Series: 30 mL
- 1000 Series: 45 mL
Maximum Operating Temperature
- 60 °C (140 °F) at 2.1 bar (210 kPa, 30 psi)
Maximum Operating Pressure
- Continuous: 4.1 bar (410 kPa, 60 psi) at ambient temperature
Recommended Integrity Test Minimum Bubble Point – Water
- 0.2 μm: 3.5 bar (350 kPa, 51 psi)
- 0.45 μm: 1.7 bar (170 kPa, 24 psi)
- 60% IPA/40% H2O (v:v)
- 0.1 μm: 2.4 bar (240 kPa, 35 psi)
Typical Water Flow Rate
- Lpm at 0.1 bar (10 kPa) [Lpm/psi]:
Pore Size 500 Sereis 1000 Sereis 1500 Series 0.1/0.1 µm 0.2 (0.2) 0.4 (0.3) - 0.2/0.2 µm 0.6 (0.4) 1.1 (0.8) 1.6 (1.1) 0.8/0.2 µm 1.1 (0.8) 1.6 (1.1) 2.2 (1.5) 0.8/0.45 µm 1.3 (0.9) 2.5 (1.7) -
Bacterial Retention
- 0.1/0.1 μm Capsules: Lot samples retain a minimum of 107 cfu/cm2 of A. laidlawii challenge per modified ASTM F838, current revision
- 0.2 μm Capsules: Lot samples retain a minimum of 107 cfu/cm2 of B. diminuta per modified ASTM F838, current revision
Endotoxin Level
- < 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test
Biological Safety
- Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>
Sterilization
- Sterilized by gamma irradiation
- If desired, autoclave once only prior to use at 121 - 123 °C (250 - 253 °F) for a maximum of 20 min.
Applications
- Large-volume media preparation
- Pilot-scale manufacturing
- Liquids requiring prefiltration, such as serum-containing media
- Sterile filtration of buffers
- Point-of-use filtration for laboratory water
- Reduce mycoplasma with the 0.1 µm pore size
Performance
Total Throughput Recorded for Devices with an EFA of Up to 1000 cm2

Throughput Determined using 3% TSB
Built-in Prefilter Enhances Total Throughput

Membrane Type: 47 mm Disc
Throughput Determined using 2.5 % TSB
Type
Filter Capsules
Use
Sterile Filtration and Clarification
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.