Order Products
PAREQII Filter Cartridge, AB1PAREQII7WH4
1/EA
1
Documents
Datasheets
Download:Description
For "Sterile" Filtration of Beer
Pasteurizer Replacement filter cartridges are a family of pre-filters and hydrophilic membrane filters desig ned for reliable retention of spoilage microorganisms in the filtration of beer in the CFS NEO system or standard housings.
Description
The Pasteurizer Replacement filter cartridge family was developed and validated for removal of beer spoilage microorganisms in the CFS NEO system or standard housings.
There are 6 family members providing reduction in microbial spoilage organisms from beer. Four of the beer membrane filter of the cartridges are constructed from microbial removal membranes with a correlated integrity test value. Two of the cartridges are pre-filters designed not only to protect the selected downstream beer membrane filter but also aid in the removal of beer spoilage organisms. The single open ended (SOE) configuration is designed to fit into the sanitary housings on the CFS NEO system to ensure effective microbial reduction and assembly integrity.
Pasteurizer Replacement filter cartridges are suitable for exposure to repeated hot water sanitization and in situ steam sterilization cycles for longer service life in the CFS NEO system. The optimized support and drainage materials, provide increased mechanical strength during operation, repeated hot water, chemical and steam sanitization and thus, high throughput.
Features | Benefits |
Cartridges resistant to numerous sanitization cycles |
|
Hydrophilic membranes |
|
Validated with beer spoilage microorganisms |
|
Individually serialized cartridges |
|
Integrity testable |
|
Quality
- Cartridges are produced in a controlled environment
- Manufactured according to ISO 9001:2015 certified Quality Management System
- All final filters are 100% integrity tested before manufacturing release
Food Contact Compliance
Please refer to the Pall website https://pall.com/en/food-beverage/compliance-and-safety.html for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.
Specifications
Materials of Construction
Table 1: Pre-Filters
Part Number | Media and hardware description |
AB4PAREG7WH4 | All Polypropylene media and hardware construction |
AB4PAREJ7WH4 | All Polypropylene media and hardware construction |
Table 2: Final Membrane Filters
Part Number | Media and hardware description |
ABN4PAREM7WH4 | Nylon 6:6 filter media in a Nylon 6-10 filter construction |
AB4PAREQ7WH4 | Supor® polyethersulfone filter membrane in a polypropylene filter construction |
AB+PAREQII+W+ | Supor polyethersulfone filter membrane in a polypropylene filter construction |
ABN4PAREV7WH4 | Nylon 6:6 filter media in a Nylon 6-10 filter construction |
ABN4PAREY7WH4 | Nylon 6:6 filter media in a Nylon 6-10 filter construction |
CFS NEO System
Performance
Microbial Removal Rating
Test Organism Log Reduction Value (LRV) | |||
Final Membrane Filters |
Serratia marcescens (ATCC 14756) |
Lactobacillus in beer |
Pediococcus in beer |
ABN4PAREM7WH4 | 11 | 8.5 | 9 |
AB4PAREQWH4 | 8 | 8 | 7 |
AB+PAREQII+W+ | 8 | 8 | 7 |
ABN4PAREV7WH4 | 7.5 | 9 | 8 |
ABN4PAREY7WH4 | 6 | 8 | 8 |
Pre-filters | Serratia marcescens (ATCC 14756) |
Lactobacillus in beer |
Pediococcus in beer |
AB4PAREG7WH4 | 4 | - | - |
AB4PAREJ7WH4 | 2.5 | - | - |
Challenges were performed at a level of ≥107 per cm2 of effective filtration area on new and unused filters. For detailed information regarding microbial removal please contact Pall for the appropriate technical performance guide.
+See next page for construction and ordering details
*Filters provided a yeast free effluent when challenged.
Type
Ordering Information
Ordering Information for Extended Line of Supor Polyethersulfone Filter Membrane in Polypropylene Laid Over Pleat Configuration
Cartridge Part Number
AB [Table 1] PAREQII [Table 2] W [Table 3] [Table 4]
This is a guide to the Part Numbering structure only. For specific options, please contact Pall.
Table 1: Nominal Length
Code | Description |
1 | 254 mm (10”) |
2 | 508 mm (20”) |
3 | 762 mm (30”) |
4* | 1016 mm (40”) |
*40” filter elements are suitable for use in a CFS system
Table 2: Adaptor
Code | Description |
3 | SOE – single open end with flat closed end and external 222 O-rings |
7 | SOE – single open end with fin end, 2 locking tabs and external 226 O-rings |
8 | SOE – single open end with fin end and external 222 O-rings |
9 | SOE – single open end with fin end, 3 locking tabs and external 222 O-rings |
Table 3: O-Ring Seal Material
Code | Description |
H4 | Silicone Elastomer |
J | Silicone Elastomer J Ethylene Propylene Rubber |
Table 4: Sterilization and Sanitization
Media | Temperature | Cumulative Exposure Time*/ cycles |
Steam | 125 °C (257 °F) | 125 x 20 min cycles |
Hot Water | 90 °C (194 °F) | 200 x 30 min cycles |
*Measured under laboratory test conditions. The actual cumulative time depends on the process conditions. For applications requiring sterilization or sanitization Pall recommends the use of Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Contact Pall for recommended procedures.