Documents
Datasheets
Download:Description
Fluorodyne II filter cartridges are hydrophilic membrane filters designed for reliable retention of bacteria in the final filtration of bottled water.
Description
The Fluorodyne II JSD filter was developed and validated to provide enhanced, secure and reliable removal of microorganisms from bottled water. The cartridge is constructed from serial layers of 0.2 and
The Fluorodyne II JSD filter is suitable for exposure to in situ steam sanitization cycles for longer service life.
This filter is integrity testable. An in-situ and non-destructive integrity test can provide assurance of filter performance within minutes. Integrity tests help manufacturers avoid costly issues such as product contamination, product losses, reprocessing and production delays, as well as satisfying auditor requirements.
Learn more about the importance of Integrity Testing and microbial filtration
Media
- Hydrophilic, easy to wet and integrity test
- Fixed pores, non-shedding, resin and surfactant free
Element
- Multiple adapter options for installation into sanitary housings
- Repeated sanitization/sterilization capability for economical operation
- Individually serialized for full traceability
Quality
- Cartridges produced in a controlled environment
- Manufactured according to ISO 9001:2000 certified Quality Management System
Microbial Removal Rating
Fluorodyne II JSD filter cartridges, passing an appropriate integrity test, provide a sterile effluent when challenged with Brevundimonas diminuta at ≥1 x 107 CFU per cm2 of effective filtration area.
Fluorodyne II JSD filter cartridges passing the appropriate Forward Flow integrity test have also been shown in laboratory tests to give titre reductions of typically 108 when challenged with Acholeplasma laidlawii ATCC28206 at a challenge level of 107 per cm2 filtration area.
Materials of Construction
Filter Medium | Hydrophilic polyvinylidene fluoride |
Support and Drainage | Polypropylene |
Core, Cage, End Cap and Fin End | Polypropylene |
Adaptor | Polypropylene with internal stainless steel reinforcing ring |
O-ring Seal | Silicone elastomer (H4) |
Specifications
Technical Information
Operating Characteristics in Compatible Fluids1
Maximum Differential Pressure | Operating Temperature |
5.3 bard (76.9 psid) (forward pressure) | 50 °C (122 °F) |
3.4 bard (49.3 psid) (forward pressure) | 80 °C (176 °F)2 |
300 |
In normal operation or in situ steam sterilization |
2 Maximum operating temperature is 90 °C.
Sterilization and Sanitization
Fluorodyne II JSD filters may be repeatedly steam sterilized.
Media | Temperature | Cumulative Time/Cycles3 |
Steam | 140 °C (284 °F) | 5 hours /5 cycles |
Steam | 125 °C (257 °F) | 30 hours / 30 cycles |
Steam (reverse) | 125 °C (257 °F) | 5 hours / 5 cycles |
Pressure Drop vs. Liquid Flow Rate4
4.2 liters per minute @ 100
0.76 US
Type
Use
Ordering Information
This is a guide to the Part Numbering structure only. For specific options, please contact Pall.
Table 1: Nominal Length
Code | Description |
1 | 254 mm (10") |
2 | 508 mm (20") |
3 | 762 mm (30") |
4 | 1016 mm (40") |
Table 2: Adaptor
Code | Description |
7 | SOE – single end with fin end, 2 locking tabs and external 226 O-rings |
28* | SOE – single open end with fin end, 3 locking tabs and external 222 O-rings |
Reviews
We appreciate your review of this product. Please login to your account to leave a review.