Features
- Flows to 265 L/min (70 US gpm)
- Pressures to 41 bar (600 psi)
- Port size ¾", 1" and 1¼"
- Patented Ultipleat (laid-over pleat) filter medium pack
- Coreless, cageless element configuration
- Pall Stress-Resistant Technology (SRT) Media
- In-to-out filter element flow path
The UR219 Series is a Preferred Product Line utilizing Stress-Resistant Technology. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.
Filter Housing
- Maximum Working Pressure:
41 bar (600 psi) - Rated Fatigue Pressure:
41 bar (600 psi) 106 cycles per NFPA T2.06.01R2-2001 Typical Burst Pressure: 145 bar (2100 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids - Materials of Construction:
Aluminum alloy head, tube and cap
Filter Element
- Filter Element Burst Pressure:
10 bard (150 psid) - Ultipleat SRT Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.
Length Code | ‘C’ Option Overall Length mm (in.) | ‘C’ Option Element Removal Clearance mm (in.) | Empty Weights kg (lb) |
04 | 246 (9.72) | 130 (5) | 2.5 (5.6) |
08 | 348 (13.72) | 230 (9) | 3.1 (6.8) |
13 | 483 (19.02) | 370 (14.5) | 3.6 (7.9) |
20 | 653 (25.72) | 530 (21) | 3.9 (8.5) |


Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.
Element Pressure Drop
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.219 Series Filter Elements — bard/1000 L/min (psid/US gpm)
Length Code | AZ | AP | AN | AS | AT |
04 | 20.07 (1.102) | 8.51 (0.467) | 5.72 (0.314) | 3.55 (0.195) | 2.69 (0.148) |
08 | 9.93 (0.545) | 4.21 (0.231) | 2.83 (0.155) | 1.76 (0.096) | 1.33 (0.073) |
20 | 5.95 (0.327) | 2.52 (0.139) | 1.70 (0.093) | 1.05 (0.058) | 0.80 (0.044) |
40 | 3.95 (0.217) | 1.68 (0.092) | 1.13 (0.062) | 0.70 (0.038) | 0.53 (0.029) |
Sample ΔP calculation
UR219 Series 13" length housing with C20 (11⁄4" BSP) threaded ports using AN grade media. Operating conditions 150 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.41 x 1.2/0.9) bard (housing)
+ ((150 x 1.70/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.55 bard (housing) + 0.53 bard (element)
= 1.08 bard (15.7 psid)
Housings, Vessels, or Assemblies
Please select only from the following list of standard filter housing options.
The specification of each filter housing part number is outlined in the tables below.
Seal Kit P/N: UR 219 SKZ
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Available UR219 Series Options
UR219CA16 08ZA1 UR219CC16 08ZA1 UR219CA16 13ZA1 UR219CC16 13ZA1 UR219CA16 20ZA1 UR219CC16 20ZA1 UR219CA20 08ZA1 UR219CC20 08ZA1 UR219CA20 13ZA1 UR219CC20 13ZA1 UR219CA20 20ZA1 UR219CC20 20ZA1 UR219CA16 08ZG1 UR219CC16 08ZG1 UR219CA16 13ZG1 UR219CC16 13ZG1 UR219CA16 20ZG1 UR219CC16 20ZG1 | UR219CA20 08ZG1 UR219CC20 08ZG1 UR219CA20 13ZG1 UR219CC20 13ZG1 UR219CA20 20ZG1 UR219CC20 20ZG1 UR219CA16 08ZN1 UR219CC16 08ZN1 UR219CA16 13ZN1 UR219CC16 13ZN1 UR219CA16 20ZN1 UR219CC16 20ZN1 UR219CA20 08ZN1 UR219CC20 08ZN1 UR219CA20 13ZN1 UR219CC20 13ZN1 UR219CA20 20ZN1 UR219CC20 20ZN1 |
The specification of each filter housing part number is outlined in the tables below.
Section 1
Housing P/N: UR 219 [Table 1] [Table 2] ++ [Table 3] Z [Table 4] 1Seal Kit P/N: UR 219 SKZ
Note: Pall Ultipleat SRT filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The suffix '1' at the end of the Housing P/N designates 1 indicator port fitted with a plug.
*Other seal material options are available; Contact Pall.
Table 1: Housing Orientation Options
Code | Port |
C | Cap service (tube up) -standard |
Table 2: Housing Port Options
Code | Port |
A16 | 1" SAE J514 straight thread |
A20 | 11⁄4" SAE J514 straight thread |
C16 | 1" BSP ISO 228 threads |
C20 | 11⁄4" BSP ISO 228 threads |
Table 3: Housing Length Options
Code | Length (in.)* |
08 | 8 |
13 | 13 |
20 | 20 |
* Nominal length
Table 4: Housing Bypass Valve Options
Code | Valve |
A | 1.7 bard - 25 psid - Use 084 code indicator only |
G | 4.5 bard - 65 psid - Use 091 code indicator only |
N | Non-Bypass - Use 091 code indicator only |
Section 2
Element P/N: UE 219 [Table 1] [Table 2] ZNote: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 | CST Rating* |
AZ | 3 | 08/04/01 |
AP | 5 | 12/07/02 |
AN | 7 | 15/11/04 |
AS | 12 | 16/13/04 |
AT | 22 | 17/15/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Table 2: Filter Element Length Options
Code | Length (in.)* |
04 | 4 |
08 | 8 |
13 | 13 |
20 | 20 |
* Nominal length
Section 3 (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Differential Pressure Indicator P/N: RC [Table 1] [Table 2] Z[Table 3] [Table 4]Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HA9000-P8-Kit Z) must be ordered separately and fitted to replace the plastic shipping plug.
Table 1: Differential Pressure Indicator Options*
Code | Indicator | 'H' Dim. |
778NZ | 'P' type Visual indicator with thermal lockout | 21mm (0.83in.) |
860MZ | 'D' type Visual indicator with no thermal lockout | 21mm (0.83in.) |
861CZ | 'L' type Electrical switch (SPDT) with 6" leads | 38mm (1.50in.) |
861CZ | 'M' type Electrical switch (SPDT) with DIN43650 connector and matching cap | 78mm (3.07in.) |
861CZ | 'R' type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap | 89mm (3.50in.) |
771BZ | 'S' type Electrical switch (SPDT) with 3-pin MS connector | 57mm (2.24in.) |
* Other options available on application.
Table 2: Indicator Pressure Setting Option*
Code | Valve |
084 | For 'A' Valve Option - Housings (1.1 bard - 16 psid) |
091 | For 'G' and 'N' Valve Options - Housings (3.5 bard - 50 psid) |
* Other setting options are available; contact Pall.
Table 3: 'M' & 'R'-Type Indicator Codes*
Code | Option |
YM | 'M' option |
YR | 'R' option |
* Use only if 'R' or 'M' Indicator is selected from Table 1
Table 4: 'R' Indicator Options
Code | Column2 |
110AC | 110V AC |
220AC | 220V AC |
220V AC | 24V DC |
* Use only if 'R' Indicator is selected from Table 1