Like the Pall PCM400, the new improved PCM500 uses proven mesh Blockage technology to report accurate, reliable, 3 part ISO 4406 cleanliness codes for most types of fluids, in many types of environment.
With the PCM500 you can:
- Monitor contamination levels in mineral, synthetic, or water based fluids. Results are unaffected by the presence of water, air, or dark fluids
- Get accurate, 3 part* ISO 4406 cleanliness code results in under 6 minutes and quickly take preventative action
- Upload real-time results directly to mobile devices for analysis and action
- 'Pass off' cleanliness of new builds quickly and confidently
- Protect your systems from catastrophic failure by detecting abnormal fluid cleanliness conditions quickly
The PCM500 can be permanently installed to monitor critical applications (including component test facilities) or used as a portable device for routine condition monitoring of various fluid systems
PCM500 Monitor Features
* 3 part code measured at 4 µm, 6 µm and 14 µm (c) per ISO 16889. |
![]() For ordering and pricing information contact your local sales office or distributor Contact Us. |
Specifications
Power supply: | 90-260 VAC or integral 12 VDC Lithium Ion battery |
Battery life: | Typically 35 samples |
Temperature: | 10°C to 80°C (50°F to 176°F) |
Range: | (dependent on fluid type) |
Compatibility: | Water glycols, aqueous solutions. Petroleum and synthetic oils (hydraulic lubricating, dielectric, etc.) fuels, industrial phosphate esters. |
Seals: | Fluorocarbon |
Operating viscosity: | 1.5 to 450 cSt (30 to 2,200 SUS) |
Pressure: | 0 to 315 bar (4568 psi) max |
Monitoring Range: | ISO 4406: <11/9/7 to 23/21/17 SAE AS 4059 Table 1 Class 1 to 12 (derived from NAS 1638) SAE AS 4059 Table 2 >4 µm 1A to 12A, >6 µm 1B to 12B >14 µm 1C to 12C |
Water in Oil % RH: | ± 2% at 5 to 95% RH (PCM500W) |
Accuracy: | ± 1/2 ISO 4406 Code |
Communication Ports: | 3 x USB's (Data Acquisition, PC Setup, Printer), Ethernet and RS232C (PLC Control) |
Enclosure: | IP 65 (NEMA 4) |
Weight: | 11 kg (24 lb) |
Dimensions: | 400 x 260 x 250 mm (15.8 x 10.2 x 10 inches) |
![]() Real time data is displayed during test to show progress |
![]() Multiple test data can be stored and displayed for subsequent analysis and download |
Applications
|
![]() |
For ordering and pricing information contact your local sales office or distributor Contact Us.
Type
Use
Ordering Information
Table 1: Fitting Type
Table 2: Power Lead
|
![]() |
Printer Kit and Accessories
PCM500-PRTFor ordering and pricing information contact your local sales office or distributor Contact Us.
Reviews
We appreciate your review of this product. Please login to your account to leave a review.