Documents
Datasheets
Download:Description
Athalon™ maximum-life filters deliver the highest level of sustained fluid system protection, across all applications, regardless of severity.
Featuring an industry leading BetaX(C)=2000* filter efficiency; the highest rated filter performance available today.
(* per ISO 16889)
- Keeps fluids the cleanest, longest, for the greatest value
- Provides consistent, reliable, protection of system components over the full service life of the filter element
- Rapidly achieves and sustains required fluid system cleanliness
- Delivers maximum filter capacity in the smallest footprint
- Prevents electrostatic discharge from damaging your filter and degrading your fluid
Features
- Patented Ultipleat (laid-over pleat) filter medium pack
- Pall Stress-Resistant Technology (SRT) Media
- Coreless filter element configuration
- Low clean differential pressure for low energy operation
Specifications
Specifications Filter Housing
- Flows to 760 L/min (200 US gpm)
- Pressures to 41 Bar (600 psi)
- Port Size 1½" 2" and 2½"
- Rated Fatigue Pressure:
0 - 41 bar (600 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million cycles), verified by testing at 0-48 bar (687 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles - Filter Element Burst Pressure: 10 bard (150 psid)
- Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29 ˚C to 120 ˚C (-20 ˚F to 248 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids - Bypass Valve Setting:
4.5 bard (65 psid) or
1.7 bard (25 psid) - Indicator Pressure Setting:
3.5 Bard (50 psid) or
1.1 bard (16 psid) - Materials of Construction:
Head and Cover: Ductile Cast Iron
Tube: Carbon steel - Filter Element :
Inorganic fibers impregnated and bonded with epoxy resins.
Polymer endcaps. Anti-static media design
Dimensional Drawings
Dimensions in mm (inches)Length Code | Overall length mm (in) |
Cover Service Element Removal Clearance mm (in) |
Head Service Element Removal Clearance mm (in) |
Empty Weight kg (lb) |
8 | 452.1 (17.80) | 248 (9.8) | 290 (11.4) | 14 (30.9) |
13 | 586.7 (23.10) | 383 (15.1) | 437 (17.2) | 16.5 (36.4) |
20 | 756.9 (29.80) | 553 (21.8) | N/A | 19.7 (43.4) |
40 | 1264.9 (49.80) | 1061 (41.8) | N/A | 29.2 (64.2) |
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.
Element Pressure Drop
310 Series Filter Elements – bard/1000 L/min (psid/US gpm)Length Code | AZ | AP | AN | AS | AT |
08 | 5.52 (0.302) | 2.30 (0.126) | 1.82 (0.100) | 1.32 (0.072) | 0.82 (0.045) |
13 | 3.31 (0.182) | 1.38 (0.076) | 1.09 (0.060) | 0.79 (0.043) | 0.49 (0.027) |
20 | 2.18 (0.120) | 0.91 (0.050) | 0.72 (0.040) | 0.52 (0.029) | 0.33 (0.018) |
40 | 1.10 (0.060) | 0.46 (0.025) | 0.36 (0.020) | 0.26 (0.014) | 0.16 (0.009) |
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm
Sample ΔP calculation
UR310 Series 13" length housing with C24 ( 1½" BSPP) ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP= ΔP housing + ΔP element
= (0.3 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.4 (housing) + 0.68 bard (element)
= 1.08 bard (15.68 psid)
Type
Ordering Information
For new installations, select one complete part number from each section below
Section 1
Housing P/N: UR310 [Table A][Table B]
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.
Table A | Table B |
Port & Length Options Tables 1, 2 and 3 |
Bypass & Orientation Options Tables 4 |
A2408Z | A, AH, G and GH |
A2413Z | A, AH, G and GH |
A2420Z | A and G |
A3213Z | A, AH, G and GH |
A3220Z | A and G |
A3240Z | A and G |
C2408Z | A, AH, G and GH |
C2413Z | A, AH, G and GH |
C2420Z | A and G |
C3213Z | A, AH, G and GH |
C3220Z | A and G |
C3240Z | A and G |
D3213Z | A, AH, G and GH |
D3220Z | A and G |
D3240Z | A and G |
D4013Z | AH and GH |
D4020Z | A and G |
D4040Z | A and G |
F3213Z | A, AH, G and GH |
F3220Z | A and G |
F3240Z | A and G |
F4013Z | AH and GH |
F4020Z | A and G |
F4040Z | A and G |
Table 1: Housing Port Options
Code | Port Style |
A | SAE J1926 straight thread |
C | BSP ISO 228 threads |
D | Flange J518C Code 61 |
F | ISO 6162 split flange |
Table 2: Port Size
Code | Port Style |
24 | 1 1/2" nominal |
32 | 2" nominal |
40 | 2 ½" nominal |
Table 3: Housing Length and Seal Options
Code | Length and Seal Material |
08Z | 8" nominal length, fluorocarbon seals |
13Z | 13" nominal length, fluorocarbon seals |
20Z | 20" nominal length, fluorocarbon seals |
40Z | 40" nominal length, fluorocarbon seals |
Table 4: Bypass Valve and Service Options
Code | Bypass Valve and Service Type |
A | 1.7 bard (25 psid) bypass valve, cover service |
AH | 1.7 bard (25 psid) bypass valve, head service |
G | 4.5 bard (65 psid) bypass valve, cover service |
GH | 4.5 bard (65 psid) bypass valve, head service |
Seal Kit P/N: SR310SKZ
*Other seal material options are available; Contact Pall.
Section 2
Element P/N: UE 310 [Table 5][Table 3]
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 5: Filter Element Options
Code | ßx(c) ≥2000 based on ISO 16889 | CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 25 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Section 3 (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Differential Pressure Indicator P/N: RC [Table 6] Z [Table 7] Z
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 6: Indicator Options
Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Other options are available; contact Pall.
Table 7: Indicator Pressue Setting Option
Code | Valve |
084 | For 'A' Valve Option - Housings (1.1 bard - 16 psid) |
091 | For 'G' Valve Option - Housings (3.5 bard - 50 psid) |
Other setting options are available; contact Pall.
Reviews