F310 Series Versalon® Medium Pressure Filters product photo Primary L

F310 Series Versalon® Medium Pressure Filters

Features

  • Flows to 120 L/min (32 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 1 in.
  • Out-to-in filter element flow path


Contact Us
* Required

Documents

Datasheets

Download: English

Description

Features

  • Flows to 120 L/min (32 US gpm)
  • Pressures to 70 bar (1015 psi)
  • Port size 1 in.
  • Out-to-in filter element flow path

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    70 bar (1015 psi)
  • Rated Fatigue Pressure:
    0 - 40 bar (580 psi) per NFPA T2.6.1 R2-2001 CAT C/90, verified by testing at 0 - 46.5 bar (675 psi)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Maximum operating temperature: 120 ˚C (250 ˚F)
    Minimum operating temperature: -25 ˚C (-13 ˚F)
    Minimum ambient temperature: -40 ˚C (-40 ˚F)
  • Bypass Valve Settings:
    ‘B’ option – 3.4±0.3 bard (50±4 psid)
    ‘G’ option – 4.5±0.5 bard (65±7 psid)
  • Indicator Pressure Settings:
    2.4±0.3 bard (35±4 psid) for ‘B’option
    3.4±0.5 bard (50±7 psid) for ‘G’option
  • Materials of Construction:
    Head - SG Iron
    Bowl - Aluminium

Filter Element

  • Filter Element Collapse Pressure:
    10 bard (145 psid)
  • Filter Element Construction:
    Inorganic fibers impregnated and bonded with specifically formulated resins. Polyamide endcaps. Corrosion protected carbon steel core.

Dimensional Drawings

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.



HCG300 Filter Elements – bard/1000 L/min (psid/US gpm)

 
Length Code CN CS KD CT
04 5.60 (0.34) 4.17 (0.23) 2.68 (0.15) 2.87 (0.16)
08 3.04 (0.17) 2.26 (0.12) 1.41 (0.08) 1.56 (0.09)
 


Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

Sample ΔP calculation


F310 Series 4” length housing with C16 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 20 cSt and specific gravity (S.G.) 1.2.

Total FilterΔP
= ΔP housing + ΔP element
= (0.32 x 1.2/0.9) bard (housing)
   + ((100 x 5.35/1000) x 20/32 x 1.2/0.9) bard (element)
= 0.427 bard (housing) + 0.445 bard (element)
= 0.873 bard (12.7 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

 
Part Number Description
HZF310A16CNSS00001 HZF310A16CNSGD1X160
HZF310C16CSRB00001 HZF310C16CSRB11X160
HZF310C16CSSS00001 HZF310C16CSSGD1X160
HZF310A16CSRB00001 HZF310A16CSRB11X160
 
* Other options available, contact factory

Element P/N: HCG300F [Table 2] [Table 3]Z

Seal P/N: G300SKZ

Table 1: Housing Port Style Options

 
Code Port Style
A16 SAE J1926 straight thread
C16 BSP threads to ISO228
 

Table 2: Filter Element Options

 
Code ßx(c) ≥1000 based on ISO 16889
CN 7
CS 12
KD 19
CT 22
 

Table 3: Length Options

 
Housing Code Element Code Length (in)*
R 4 127 mm (5.00 in.)
S 8 219 mm (8.62 in.)
 
* Nominal length

Table 4: Valve Options

 
Code Option
B 3.4 ± 0.4 bard (50 ± 6 psid)
G 4.5 ± 0.5 bard (65 ± 7 psid)
 

Table 5: Differential Pressure Indicator Port Options

 
Code Indicator
D Visual indicator
1 Machined port with plastic shipping plug Indicator must be installed prior to operation
 

Reviews