Datasheets
Download:Features
- Flows to 50 L/min (13 US gpm)
- Pressures to 250 bar (3625 psi)
- Port size 1⁄2 in., 5⁄8 in. and M22
- Out-to-in filter element flow path
Filter Housing
- Maximum Allowable Working Pressure:
250 bar (3625 psi) - Rated Fatigue Pressure:
0-240 bar (0-3480 psi) per NFPA T2.06.01R2-2001
CAT C/90/*(1 million cycles), verified by testing at 0-280 bar (0-4060 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29 ºC to 120 ºC (-20 ºF to 250 ºF)
50 ºC (122 ºF) maximum in HWCF or water glycol fluids - Bypass Valve Settings:
4.5 ± 0.5 bard (65 ± 7 psid) - Indicator Pressure Settings:
3.4 ± 0.4 bard (50 ± 6 psid) - Materials of Construction:
Head: SG Iron
Bowl: Carbon steel
Filter Element
- Filter Element Burst Pressure:
10 bard (145 psid) - Filter Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polyamide endcaps. Corrosion protected carbon steel core
Dimensional Drawings

Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.
HCG200 Filter Elements – bard/1000 L/min (psid/US gpm)
Length Code | KN | KS | KD | KT |
04 | 9.35 (0.51) | 4.90 (0.27) | 4.94 (0.27) | 3.92 (0.21) |
08 | 4.90 (0.27) | 3.33 (0.18) | 2.56 (0.14) | 2.04 (0.11) |
Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.
Sample ΔP calculation
G210 Series 8 in. length housing with M22 ports using KN grade media. Operating conditions 50 L/min (13 US gpm) flow rate using a hydraulic fluid at 45 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.55 x 1.2/0.9) bard (housing)
+ ((50 X 4.9/1000) X 45/32 X 1.2/0.9) bard (element)
= 0.73 bard (housing) + 0.46 bard (element)
= 1.19 bard (17.3 psid)
Housings, Vessels, or Assemblies
Housing P/N:
HZG210 [Table 1] [Table 2] [Table 3] [Table 41] G [Table 5] X160
Element P/N: HCG200F [Table 3] [Table 4] Z
Seal P/N: G200SKZ
HZG210 [Table 1] [Table 2] [Table 3] [Table 41] G [Table 5] X160
Element P/N: HCG200F [Table 3] [Table 4] Z
Seal P/N: G200SKZ
Table 1: Housing Port Style Options
Code | Port Style |
A | Straight threads & 0-Ring boss to SAE J1926 |
M | Metric threads to BS3643 |
C | BSP threads to ISO228 |
Table 2: Housing Port Sizes Options
Code | Port Size | Styles Available |
08 | Nominally 1⁄2 in. | ‘C’ |
10 | Nominally 5⁄8 in. | ‘A’ |
22 | M22x1.5-6H THD | ‘M’ |
Table 3: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 |
KN | 7 |
KS | 12 |
KD | 19 |
KT | 22 |
Table 4: Length Options
Housing Code | Element Code | ‘L’ Dim* |
R | 4 | 100.2 mm (3.95 in.) |
S | 8 | 192.9 mm (7.59 in.) |
* Nominal length
Table 5: Differential Pressure Indicator Options
Code | Indicator | ‘H’ Dim. |
0 | Unmachined indicator port | - |
1 | Machined port with plastic shipping plug Indicator must be installed prior to operation. Only available to distributors |
- |
B | Bleed plug and seal in place of indicator | 16 |
C | Electrical switch - normally closed, automatic reset Connection: Deutsch DT042P |
74 |
D | Visual indicator, window changes from white to red on indication. Automatic reset | 36 |
U | Electrical switch - normally closed, automatic reset Connection: AMP junior timer connector |
67 |
We appreciate your review of this product. Please login to your account to leave a review.