RCA216 / RCA217 / RCA218 / RCA219 product photo Primary L

Differential Pressure Indicators

Deltadyne Differential Pressure Switch

Pall RCA series differential pressure indicators signal the need for filter element change by sensing the differential pressure between ports upstream and downstream of the filter element. They connect to the Deltadyne™ device port available on Pall filter housings.

Electrical Connection



The switch is wired normally closed. Using normally closed configuration allows for the detection of damaged or broken cables or disconnection. The switch will automatically reset when differential pressure is reduced.



Switch can be wired using either normally open or normally closed configuration. The switch will automatically reset when differential pressure is reduced.


Contact Us
* Required
Product ID: RCA222ZK4024

Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
1.8 bar
Maximum Pressure Range (Metric)
4 bar
Minimum Pressure Range (Metric)
1 bar
See All Attributes

Product ID: RCA222ZK2011

Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
0.8 bar
Maximum Pressure Range (Metric)
2 bar
Minimum Pressure Range (Metric)
0.5 bar
See All Attributes

Product ID: RCA222ZK4034

Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
2.4 bar
Maximum Pressure Range (Metric)
4 bar
Minimum Pressure Range (Metric)
1 bar
See All Attributes

Product ID: RCA222ZK8069

Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
4.8 bar
Maximum Pressure Range (Metric)
8 bar
Minimum Pressure Range (Metric)
2 bar
See All Attributes

Product ID: RCA216CZ091Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
Normally Closed

Product ID: RCA216CZ090ZX

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
Normally Open

Product ID: RCA217UZ090ZX

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
Normally Open

Product ID: RCA217UZ090Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
Normally Closed

Product ID: RCA217UZ091Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
Normally Closed

Product ID: RCA217UZ091ZX

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
Normally Open

Product ID: RCA218MZ091Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA218MZ084Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
1.1 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA218MZ097Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
6.9 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA218RZ090Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA218RZ084Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
1.1 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA218RZ091Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
SPDT

Product ID: RCA219DZ090Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
Visual

Product ID: RCA219DZ097Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
6.9 bar
Seal Material
Viton
Switch Type
Visual

Product ID: RCA219DZ084Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
1.1 bar
Seal Material
Viton
Switch Type
Visual

Product ID: RCA219DZ091Z

Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
Visual

Datasheets

Download: English

Deltadyne Differential Pressure Switch

Pall RCA series differential pressure indicators signal the need for filter element change by sensing the differential pressure between ports upstream and downstream of the filter element. They connect to the Deltadyne™ device port available on Pall filter housings.

Electrical Connection



The switch is wired normally closed. Using normally closed configuration allows for the detection of damaged or broken cables or disconnection. The switch will automatically reset when differential pressure is reduced.



Switch can be wired using either normally open or normally closed configuration. The switch will automatically reset when differential pressure is reduced.
 
Fatigue Test Pressure: 1 Million cycles at 0-400 bar (5800psi)
Operating Temperature: Maximum Operating Temperature 120 °C (250 °F)
Minimum Operating Temperature -20 °C (-4 °F)
Minimum Ambient Temperature: -40 °C (-40 °F)
Fluid Compatibility: Standard mineral oils and hydrocarbon-based synthetic Hydraulic and Lubrication fluids and Fuels
Materials of Construction: Brass body
Seal Materials: Fluorocarbon
Environmental: IP67 to IEC 60529
connected or unconnected
Switch:
RCA216/217
Normally closed single pole open on differential pressure exceeding set point
Switching Voltage: 48V DC Maximum
Switching Current: 0.5 A Maximum
Electrical Connectors: RCA 216 - Connector Deustch
DT04-2P to mate with Deutsch
DT06-2S receptacle
RCA 217 - Connector AMP Junior timer to mate with AMP junior timer receptacle 827551-3 and contacts 925596-1
Switch:
RCA218M
Single pole, double throw (SPDT) switch state changes on differential pressure exceeding set point
Switching Voltage: 48V DC Maximum or 250V AC
Switching Current: 4 A Maximum
Electrical Connectors: Hirschmann type
Switch:
RCA218R
Single pole, double throw (SPDT) switch state changes on differential pressure exceeding set point
Switching Voltage: 24V DC
Switching Current: 4 A Maximum
Electrical Connectors: Hirschmann type with red and green LEDs that illuminate when switch operates
Visual indicator:
RCA219
Window changes from white to red on detnation. All units automatically reset when differential pressure drops below set-point.
System Interface: To fit all standard Pall threaded indicator ports
 
Diagnostic and Monitoring Equipment
Monitoring
Pressure Switch P/N: RCA [Table 1] Z [Table 2] Z

Table 1 - Connector Option

 
Code Connector
216C Deutsch DT04-2P
217U AMP Junior Timer
218M Hirschmann
218R Hirscmann with Red and Green LED indicators
219D Visual Indicator
 

Table 2 - Pressure Setting

 
Code Pressure
090 2.4 ± 0.3 bard (35 ± 4 psid)
091 3.4 ± 0.4 bard (50 ± 6 psid)
 

We appreciate your review of this product. Please login to your account to leave a review.