G410 Series 'T' Filters product photo Primary L

G410 Series 'T' Filters

Features

  • Out-to-in filter element flow path
  • Flows to 250 L/min (66 US gpm)
  • Pressures to 420 bar (6090 psi)
  • Port size 1 in. and 1 1?4 in.


Contact Us
* Required

Documents

Datasheets

Download: English

Description

Features

  • Out-to-in filter element flow path
  • Flows to 250 L/min (66 US gpm)
  • Pressures to 420 bar (6090 psi)
  • Port size 1 in. and 1 1?4 in.

Specifications

Filter Housing

  • Maximum Working Pressure: 420 bar (6090 psi)
  • Rated Fatigue Pressure: 0-240 bar (0-3480 psi) per NFPA T2.6.1 R2-2001 CAT C/90. Verified by testing at 0-280 bar (0-4060 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles
  • Fluid Compatibility: Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    • Nitrile Seals: -43 ®C to 120 ®C (-46 ®F to 250 ®F) 60 ®C (140 ®F) maximum in HWCF or water glycol fluids
    • Fluorocarbon Seals: -29 ®C to 120 ®C (-20 ®F to 250 ®F)
  • Bypass Valve Settings: 4.5 bard (65 psid)
  • Indicator Pressure Settings: 3.4 bard (50 psid)
  • Materials of Construction:
    • Head: SG Iron
    • Bowl: Carbon steel

Filter Element

  • Filter Element Burst Pressure: 10 bard (145 psid)
  • Filter Element Construction: Inorganic fibers impregnated and bonded with epoxy resins. Polyamide endcaps. Corrosion protected carbon steel.

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.



HCG300 Filter Elements ® bard/1000 L/min (psid/US gpm)

Length Code KN KS KD KT
08 3.83 (0.21) 2.92 (0.16) 2.73 (0.15) 2.01 (0.11)
10 3.10 (0.17) 2.37 (0.13) 2.22 (0.12) 1.64 (0.09)

Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

Sample ?P calculation

G410 Series 8 in. length housing with C20 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cSt and specific gravity (s.g.) 1.2.

Total Filter ?P

  • ?P housing + ?P element
  • (0.22 x 1.2/0.9) bard (housing)
    • ((100 x 3.83/1000) x 45/32 x 1.2/0.9) bard (element)
  • 0.29 bard (housing) + 0.71 bard (element)
  • 1.00 bard (14.5 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

Housing P/N: H [1] G4 [2] 0 [3] [4] [5] G [6] [7] X160
Element P/N: HCG300F [4] [5] [1]
Seal P/N: G400SK [1]

Table 1: Seal Options

Code Seal Material Fluid Service
H Nitrile Water Glycol Emulsions
Water - Oil Petroleum
Z Fluorocarbon Specified Synthetics

Table 2: Housing Port

Code Option
0 'L' Port
1 'T' Port

Table 3: Housing Port Style Options

Code Port Size Port Style Port Available
A 16 1 in. Straight threads and
O-Ring boss per SAE J1926
'L' & 'T'
A 20 11?4 in. 'L' & 'T'
B 16 1 in. NPT threads to ANSI B2.1 'L' & 'T'
B 20 11?4 in. 'L' & 'T'
C 16 1 in. BSP threads to ISO228 'L' & 'T'
C 20 11?4 in. 'L' & 'T'
E 20 11?4 in. Split flange to SAE J518C code 62 'L'
G 20 11?4 in. Split flange to SAE ISO6162 (Metric) 'L'

Table 4: Filter Element Options

Code ®x(c) ?1000 based on ISO 16889
KN 7
KS 12
KD 19
KT 22
++ No Element

Table 5: Length Options

Code Element Length Code 'L' Dim*
S 8 230.3 mm (9.07 in.)
K 10 282.0 mm (11.10 in.)
*Normal Length


Table 6: Differential Pressure Indicator Options

Code Indicator 'H' Dim.
1 Machined port with plastic shipping plug
Indicator must be installed prior to operation
Only available to distributors
-
B Bleed plug and seal in place of indicator 16
C Electrical switch - normally closed, automatic reset
Connection: Deutsch DT042P
Reed switch operation suitable for low current applications
56
D Visual indicator, red button rises 5 mm on actuation
Remains up until manually reset
23
P Visual indicator with thermal lockout and manual reset
No signal below 0 ®C, signal above 27 ®C
Indicator includes clear plastic cover and internal dirt protection
23
R Electrical switch-SPDT with neon light indicator
Connection: plug and socket as per DIN43650,
ISO 4400, Hirschmann type (24 volt DC)
90
U Electrical switch - normally closed, automatic reset
Connection: AMP junior timer connector
Reed switch operation suitable for low current applications
47

Table 7: Drain Options

Code Option
0 None
3 1?4 BSP
6 1?4 BSP

Reviews

We appreciate your review of this product. Please login to your account to leave a review.