Datasheets
Download:Athalon™ maximum-life manifold high-pressure filters deliver the highest sustained fluid system protection level across all applications, regardless of severity. Featuring an industry-leading BetaX(C)=2000* filter efficiency, these high-pressure hydraulic fluid filters have the highest-rated filter performance available today. (* per ISO 16889)
In addition they
In addition they
- Keeps fluids the cleanest, longest, for the greatest value
- Provide consistent, reliable protection of system components over the entire service life of the filter element
- Rapidly achieves and sustains the required fluid system cleanliness
- Delivers maximum filter capacity in the smallest footprint
- Prevents electrostatic discharge from damaging your filter and degrading your fluid
Features
- Patented Ultipleat (laid-over pleat) filter medium pack
- Pall Stress-Resistant Technology (SRT) Media
- Coreless filter element configuration
- Low clean pressure drop for low energy operation
Notes and Specifications Filter Housing
- Flows to 600 L/min (160 US gpm)
- Pressures to 414 bar (6000 psi)
- Port size 1½"
- Rated Fatigue Pressure:
0-240 bar (3500 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million cycles), verified by testing at 0-280 bar (4050 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles - Filter Element Burst Pressure:
10 bard (150 psid) - Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids - Bypass Valve Setting:
4.5 bard (65 psid) - Indicator Pressure Setting:
3.5 bard (50 psid) - Materials of Construction:
Head and Cover: Ductile Cast Iron
Tube: Carbon steel - Filter Element :
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
Dimensional Drawings
Dimensions in mm (inches)Length Code | Overall length mm (in) | Cover Service Element RemovalClearance mm (in) | Head Service Element Removal Clearance mm (in) | Empty Weight kg (lb) | ||
K Type Head | S Type Head | K Type Head | S Type Head | |||
08 | 444.6 (17.50) | 505.1 (19.89) | 248 (9.76) | 305 (12) | 31.7 (69.9) | 31.7 (69.9) |
13 | 579.2 (22.80) | 639.7 (25.19) | 383 (15.08) | 440 (17.32) | 36.5 (80.5) | 36.5 (80.5) |
20 | 749.4 (29.50) | 809.9 (31.89) | 553 (21.77) | N/A | 42.5 (93.9) | 42.5 (93.9) |
K24 OPTION

S24 OPTION

Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop
310 Series Filter Elements – bard/1000 L/min (psid/US gpm)
Length Code | AZ | AP | AN | AS | AT |
08 | 5.52 (0.302) | 2.30 (0.126) | 1.82 (0.100) | 1.32 (0.072) | 0.82 (0.045) |
13 | 3.31 (0.182) | 1.38 (0.076) | 1.09 (0.060) | 0.79 (0.043) | 0.49 (0.027) |
20 | 2.18 (0.120) | 0.91 (0.050) | 0.72 (0.040) | 0.52 (0.029) | 0.33 (0.018) |
40 | 1.10 (0.060) | 0.46 (0.025) | 0.36 (0.020) | 0.26 (0.014) | 0.16 (0.009) |
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm
Sample ΔP calculation
UH310 Series 13" length housing with K24 1 1/2" topmount flange using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.58 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.77 (housing) + 0.68 bard (element)
= 1.45 bard (21.1 psid)
Housings, Vessels, or Assemblies
For new installations, select one complete part number from each section below
Section 1 Housing P/N: UH310 [Table A] [Table B]
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.
Table A | Table B |
Port & Length Options | Bypass & Orientation Options |
Tables 1, 2 and 3 | Table 4 |
K24087, G3, G6, C3, C6 | G3, G6, C3, C6 |
K2420Z | G3, G6, C3, C6 |
S2408Z, G3, G6, G3H | G6H, C3, C6 |
S2413Z, G3, G6, G3H | G6H, C3, C6 |
S2420Z | G3, G6, C3, C6 |
Table 1: Housing Port Options
Code | Port Style | Max. Operating Pressure |
K | Top manifold mount | 414 bar (6000 psi) |
S | Side manifold mount | 414 bar (6000 psi) |
Table 2: Port Size
Code | Port Style |
24 | 1 1⁄2" nominal |
Table 3: Housing Length and Seal Options
Code | Length and Seal Material |
08Z | 8" nominal length, fluorocarbon seals |
13Z | 13" nominal length, fluorocarbon seals |
20Z | 20" nominal length, fluorocarbon seals |
Table 4: Bypass Valve and Service Options
Code | Bypass Valve and Service Type |
G3 | 4.5 bard (65 psid) bypass valve, Cap service, metric port |
G3H | 4.5 bard (65 psid) bypass valve, Head service, metric port |
G6 | 4.5 bard (65 psid) bypass valve, Cap service, imperial port |
G6H | 4.5 bard (65 psid) bypass valve, Head service, imperial port |
C3 | 4.5 bard (65 psid) bypass valve with reverse flow, metric port |
C6 | 4.5 bard (65 psid) bypass valve with reverse flow, imperial port |
Seal Kit P/N: SH 310 SKZ
*Other seal material options are available; Contact Pall.Section 2 Element P/N: UE 310 [Table 5] [Table 3]
Note: Z indicates fluorocarbon seals are standard.
Other options are available; contact Pall.
Table 5: Filter Element Options
Code | ßx(c) ≥2000 based on ISO 16889 | CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 25 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Section 3 (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Differential Pressure Indicator P/N:
RC [Table 6] Z091 Z [Table 7]
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 6: Indicator Options
Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Code | Stainless Steel indicator |
778NZ | Visual filter with thermal lockout |
861CZ | Electrical Switch (SPDT) with 6" leads |
861CZ* | Electrical switch (SPDT) with Hirschmann connector |
771BZ | Electrical switch (SPDT) with 3-pin |
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 7.
Table 7: Differential Pressure Indicator Material
Code | Pressure Setting |
Omit | Brass Indicator |
SS | Stainless Steel Indicator: recommended for high pressure cycle applications with pressure > 200 bar (3000 psi) |
Other setting options are available; contact Pall.
We appreciate your review of this product. Please login to your account to leave a review.