New: RCA222 Series Differential Pressure Transducer

The RCA222 Differential Pressure (ΔP) Transducer is the latest monitoring device for use with Pall filter assemblies. It provides continuous, reliable, real time data of filter service condition to give users increased control of their fluid system maintenance procedures.

The RCA222 ΔP transducer senses the differential pressure across an in-service filter element and transmits the reading as a 4-20mA analogue signal, interpreted as a value of remaining filter life.

In addition it has two independent switched outputs set to 75% and 100% of filter service life to give an initial warning (75%) that the filter element will shortly need replacing, and a final warning (100%) that a replacement filter element is needed. This helps accommodate filter changes into planned maintenance schedules.

The ‘plug and play’ transducer is designed to fit all standard Pall threaded indicator ports, regardless of filter age, for applications rated up to 450 bar.

  • Provides a more automated, continuous method for monitoring filter service life
  • Sudden changes in filter condition can help detect potentially damaging operating conditions, enabling the operator to take corrective action before failure occurs
  • No manual on-site checking of filter status required
  • Transducer thermal lockout (< 20 ºC) ignores signals received before normal operating temperature is reached, ensuring readings are relevant
  • Available in a range of standard differential pressures to suit the Pall filter housing bypass setting the transducer is intended to be used with


* Required
Need Help?
Download Datasheet
Description

The RCA222 Differential Pressure (ΔP) Transducer is the latest monitoring device for use with Pall filter assemblies. It provides continuous, reliable, real time data of filter service condition to give users increased control of their fluid system maintenance procedures.

The RCA222 ΔP transducer senses the differential pressure across an in-service filter element and transmits the reading as a 4-20mA analogue signal, interpreted as a value of remaining filter life.

In addition it has two independent switched outputs set to 75% and 100% of filter service life to give an initial warning (75%) that the filter element will shortly need replacing, and a final warning (100%) that a replacement filter element is needed. This helps accommodate filter changes into planned maintenance schedules.

The ‘plug and play’ transducer is designed to fit all standard Pall threaded indicator ports, regardless of filter age, for applications rated up to 450 bar.

  • Provides a more automated, continuous method for monitoring filter service life
  • Sudden changes in filter condition can help detect potentially damaging operating conditions, enabling the operator to take corrective action before failure occurs
  • No manual on-site checking of filter status required
  • Transducer thermal lockout (< 20 ºC) ignores signals received before normal operating temperature is reached, ensuring readings are relevant
  • Available in a range of standard differential pressures to suit the Pall filter housing bypass setting the transducer is intended to be used with
Specifications

Technical Information


Maximum operating pressure: 450 bar
Pressure fatigue rating: 0-400-0 bar >1 x 106
Proof pressure: 675 bar
Burst pressure (typical): 1100 bar
Number of cycles (Mechanical): 1 x105
Operating Temperature: -25°C(-13°F) to 85°C(185°F)
Minimum Ambient Temperature: -40°C (-40°F)
IP rating: IP65 with mating connector to M12-5 to IEC 61076-2-1001 socket plug assembly.
Connector: PA6, 6-M12-5 PIN to IEC 61076-2-101.

Materials of construction


Body, piston, spring retainer: Brass
Spring: Stainless Steel
Seals: Fluorocarbon
Indicator tightening torque: 50-60Nm.

Electrical switch ratings

24 VDC PNP Maximum load 0.4A normally open, analogue output 4-20mA.

Automatic switch reset when differential pressure is reduced.

Thermal lockout T° = 20°C (68°F) Note if T < T° Digital output 1 remains normally open, digital output 2 remains normally open and analogue output remains at 4mA.

Analogue output remains at 4mA until a minimum of 25% of differential pressure range has been exceeded (dead band).

Transducer connection

Pin 1: 24 VDC ± 10%
Pin 2: Analogue Output 4-20mA
Pin 3: Digital Output 1 75% (PNP)
Pin 4: Digital Output 2 100% (PNP)
Pin 5: 0 VDC, Ground


Type
Testing and Monitoring
Use
Monitoring, Testing
Ordering Information
 
Part Number Analogue Output 100% switch point 75% switch point
RCA222ZK2011 0.5 - 2.0 bard
8 – 29 psid
1.1 bard
16 psid
0.8 bard
12 psid
RCA222ZK4024 1.0 - 4.0 bard
15 – 58 psid
2.4 bard
35 psid
1.8 bard
26 psid
RCA222ZK4034 1.0 - 4.0 bard
15 – 58 psid
3.4 bard
50 psid
2.4 bard
35 psid
RCA222ZK8069 2.0 - 8.0 bard
29 – 116 psid
6.9 bard
100 psid
4.8 bard
70 psid
 
Application
Auto LOH for Stamping, Auto LOH-Filling Lines, Mining Equipment Gear Case, Mining Equipment Hydraulic Fluid, Mining Euqipment Lube Oil - on & off board, Heavy Hydraulic, Heavy Lubrication, Medium & Light Hydraulic, Medium & Light Lubrication, Coolants / Bearing Lubrication, Drives Gear Box + Roll Housing, Forging / Extrusion, Gear Box / Bearing, Gear Box / Morgoil, Material Directional Control, Material Handling, Non Contact, Medium & Light Hydraulic, Medium & Light Lubrication
Segment
Automotive
General Industrial
Industrial and Mobile OEM
Mining