Documents
Datasheets
Download:Description
Versalon™ T200 tank mounted filters deliver high-performance contaminant protection for lube and hydraulic systems in an economical package tailored for Industrial and Mobile OEMs. The T200 features Coralon® filter elements, with world-class BetaX(C)≥1000 filtration rating.
![VersalonT200Infographic](/INTERSHOP/static/WFS/PALL-Site/PALLUSP/PALL/en_US/VersalonT200Infographic.jpg)
Specifications
Notes and Specifications
Filter Housing
- Maximum Flow Rate (8-inch assembly):
150 L/min (39 USgpm ) - Maximum Allowable Working Pressure:
10 bar (145 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions, and most synthetic hydraulic and lubrication fluids - Temperature Range:
Nitrile Seals: -29°C to 100°C (-20°F to 212°F) 50°C (122°F) maximum in HWCF or water-glycol fluids - Bypass Valve Settings:
3.4 bar (50 psi) - Visual Gauge Settings:
Visual gauge with green at <2.4 bar="" 35="" psi="" and="" red="">2.4 bar (35 psi) - Materials of Construction:
Head: Aluminum alloy
Cover: Polyamide
Canister: Polyamide
Filter Element
- Filter Element Collapse Pressure:
10 bar (145psid ) - Filter Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Corrosion protected carbon steel core and end caps
![](/INTERSHOP/static/WFS/PALL-Site/PALLUSP/PALL/en_US/images/Industrial-Manufacturing/T-200_Series.jpg)
![](/INTERSHOP/static/WFS/PALL-Site/PALLUSP/PALL/en_US/images/Industrial-Manufacturing/T-200_Series_2.jpg)
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity
![](/INTERSHOP/static/WFS/PALL-Site/PALLUSP/PALL/en_US/images/Industrial-Manufacturing/T-200_Series_graph.jpg)
Element Pressure Drop
HCT200 Filter Elements – bard/1000 L/min (
Length Code | CS | CT |
04 | 6.0 (0.33) | 3.92 (0.21) |
08 | 3.33 (0.18) | 2.04 (0.11) |
Multiply actual flow rate times factor in
Note: factors are per 1000 L/min and per 1 US
Sample ΔP calculation
T200 Series 8 inch length with C16 ports using CS grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cST and specific gravity (s.g.) 1.2
Total Filter ΔP
= ΔP housing + ΔP element= (0.32 x 1.2/0.9) bard (housing)
+ ((100 x 3.3/1000) x 45/30 x 1.2/0.9) bard (element)
= 0.43 bard (housing) + 0.66 bard (element)
= 1.09 bard (15.8 psid)
Type
Ordering Information
![](/INTERSHOP/static/WFS/PALL-Site/PALLUSP/PALL/en_US/images/Industrial-Manufacturing/T-200_Series_3.jpg)
T-200_Series_2
Table 1: Housing Port Style Options
Code | Port Style |
C | BSP threads to ISO 228 |
U2 | JIS B0203 tapered pipe thread |
Table 2: Housing Port Size Options
Code | Port Size |
08 | 1/2” |
12 | 3/4” |
16 | 1" |
Table 3: Indicator Port Location
Code | Gauge Position |
1 | Position 90 degrees counter clockwise from |
2 | Position 90 degrees clockwise from |
3 | Position opposite from inlet port |
Table 4: Filter Element Options
Code | Rating (μm) βX(C)≥1000 |
CS | 12 |
CT | 22 |
Table 5: Length Options
Housing Code | Element Code | Length mm (in) |
R | 04 | 102 (4) |
S | 08 | 203 (8) |
Table 6: Bypass Valve
Code | Bypass Valve Type |
B | 3.4 ± 0.3 bar (49 ± 6 psi) |
Reviews