Notes and Specifications
Filter Housing

    • Maximum Flow Rate (8-inch assembly):
      150 L/min (39 US gpm)
    • Maximum Allowable Working Pressure:
      10 bar (145 psi)
    • Fluid Compatibility:
      Compatible with all petroleum oils, water glycols, water-oil emulsions, and most synthetic hydraulic and lubrication fluids
    • Temperature Range:
      Nitrile Seals: -29°C to 100°C (-20°F to 212°F) 50°C (122°F) maximum in HWCF or water-glycol fluids
    • Bypass Valve Settings:
      3.4 bar (50 psi)
    • Visual Gauge Settings:
      Visual gauge with green at <2.4 bar="" 35="" psi="" and="" red="">2.4 bar (35 psi)
    • Materials of Construction:
      Head: Aluminum alloy
      Cover: Polyamide
      Canister: Polyamide

Filter Element

  • Filter Element Collapse Pressure:
    10 bar (145 psid)
  • Filter Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Corrosion protected carbon steel core and end caps

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity



Element Pressure Drop

HCT200 Filter Elements – bard/1000 L/min (psid/US gpm)

 
Length Code CS CT
04 6.0 (0.33) 3.92 (0.21)
08 3.33 (0.18) 2.04 (0.11)
 

Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 30 cSt (141 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/30 (SUS/141) x new S.G./0.9.
Note: factors are per 1000 L/min and per 1 US gpm.

Sample ΔP calculation

T200 Series 8 inch length with C16 ports using CS grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cST and specific gravity (s.g.) 1.2

Total Filter ΔP

= ΔP housing + ΔP element
= (0.32 x 1.2/0.9) bard (housing)
+ ((100 x 3.3/1000) x 45/30 x 1.2/0.9) bard (element)
= 0.43 bard (housing) + 0.66 bard (element)
= 1.09 bard (15.8 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

T-200_Series_2
Table 1:
Housing Port Style Options

 
Code Port Style
C BSP threads to ISO 228
A SAE J1926 straight thread
U2 JIS B0203 tapered pipe thread
 

Table 2: Housing Port Size Options

 
Code Port Size
08 1/2”
12 3/4”
16 1"
 

Table 3: Indicator Port Location

 
Code Gauge Position
1 Position 90 degrees counter clockwise from inlet port (standard)
2 Position 90 degrees clockwise from inlet port
3 Position opposite from inlet port
 

Table 4: Filter Element Options

 
Code Rating (μm) βX(C)≥1000
CS 12
CT 22
 

Table 5: Length Options

 
Housing Code Element Code Length mm (in)
R 04 102 (4)
S 08 203 (8)
 

Table 6: Bypass Valve

 
Code Bypass Valve Type
B 3.4 ± 0.3 bar (49 ± 6 psi)
 