HDC® II filter cartridges are constructed of pure polypropylene, high area, pleated media. This new generation of HDC II filters, unlike the original HDC filters and other polypropylene pleated filters, has incorporated a proprietary concept into its medium construction: varying the fiber diameter continuously to produce a pore size distribution from coarse (upstream) to fine (downstream). This unique construction permits more contaminants to be trapped in the outer layers of the medium, thus substantially increasing dirt-holding capacity. The finer inner layers are essentially unchanged from those of the original HDC medium, thus maintaining the absolute rating of the filter.
Relative filter life studies, both in the laboratory and in the field, have shown that this new construction increases service life as much as four times compared to other filters of similar appearance.
Removal ratings range from 0.6 μm (micron) to 70.0 μm absolute. Refer to Bulletin HDC 700 for more detailed information.
Relative filter life studies, both in the laboratory and in the field, have shown that this new construction increases service life as much as four times compared to other filters of similar appearance.
Removal ratings range from 0.6 μm (micron) to 70.0 μm absolute. Refer to Bulletin HDC 700 for more detailed information.
Features | Advantages | Benefits |
Absolute Rated Medium | 99.98% removal efficiency. | Consistent, reliable filtration. |
Tapered Pore Medium | Prefilter layers. | Longer service life by factors up to 4 times. |
Fixed Pore Structure | No solids unloading or media migration. | No contamination of filtered process fluid. |
Polypropylene Medium with No Surfactants or Binders | Negligible level of extractables. | Wide chemical compatibility. |
Specifications
Operating Characteristics
The recommended maximum pressure differential for the HDC "J" Series filters is 75 psid up to 140 °F (60 °C) and 45 psid up to 180 °F (82 °C) for UNI CAP filters, and 80 psid up to 122 °F (50 °C) and 60 psid up to 176 °F (80 °C) for AB style filters.Warning: Using these filters for filtration at higher pressures or temperatures than recommended, or with fluids incompatible with polypropylene, can result in property damage or personal injury and contaminated filtrate.
Sizes
HDC II "J" Series media are available in the UNI CAP configuration. UNI CAP series pleated elements are manufactured as 2 1⁄2 in. OD by 10, 20, 30, and 40 inch long filter cartridges. Elastomeric gaskets are attached to each end cap.Sanitary (AB Style) elements are 2 3⁄4 in. OD by 10 in. single openended constructions with an O-ring piston seal at the open end. AB style elements are also available in 20, 30, and 40 inch lengths.
Applications
HDC II filters are specifically designed for use in applications where economy and reliability are critical. All materials of construction are FDA listed for direct food contact, and all components have been tested according to the USP Class VI biological tests for plastics at 250 °F (121 °C).
Representative applications include:
General Service: rinse water, reverse osmosis system prefiltration, water–prior to and/or after demineralization.
General Process Industries: electroplating solutions, metal etching solutions, audio and video tape coatings, automotive paints, can coatings, coil coatings, computer tape and disc coatings, photographic film manufacturing and processing.
Chemical/Petrochemical Industries: amines for gas scrubbing, monomers, polymers, glycols, herbicides and pesticides, liquid catalysts, product polishing, photoresists, acids, bases, solvents, deep well disposal fluids.
Film and Fiber Industries: monomers, quench water, slurry additives, delusterants, slip agents, D.I. water, solvents, spin finishes, aqueous salt solutions.
Power Generation Industries: makeup water, laundry drain wastewater, steam generator blowdown prefilters. Pharmaceutical Industry: parenterals, ophthalmics, oral medications.
Biological Industry: serum and serum fractions, tissue culture media, vaccine preparations, microbiological growth media, media makeup water, diagnostic sera.
Cosmetics: toiletries, aftershaves, perfumes, oils, lotions, creams, ointments, shampoos, body rinses, mouthwashes.
Fermentation Industries: liquid growth media, makeup water, intermediates, final liquid products, additives, exhaust gas, prefiltration.
Food and Beverage Industries: potable liquids, wine, beer, soft drinks, flavors, storage tank/reactor vents, corn syrup, edible oils.
Electronic Industries: photoresists, acids, bases, solvents, etchant gases, D.I. water prefiltration.
Representative applications include:
General Service: rinse water, reverse osmosis system prefiltration, water–prior to and/or after demineralization.
General Process Industries: electroplating solutions, metal etching solutions, audio and video tape coatings, automotive paints, can coatings, coil coatings, computer tape and disc coatings, photographic film manufacturing and processing.
Chemical/Petrochemical Industries: amines for gas scrubbing, monomers, polymers, glycols, herbicides and pesticides, liquid catalysts, product polishing, photoresists, acids, bases, solvents, deep well disposal fluids.
Film and Fiber Industries: monomers, quench water, slurry additives, delusterants, slip agents, D.I. water, solvents, spin finishes, aqueous salt solutions.
Power Generation Industries: makeup water, laundry drain wastewater, steam generator blowdown prefilters. Pharmaceutical Industry: parenterals, ophthalmics, oral medications.
Biological Industry: serum and serum fractions, tissue culture media, vaccine preparations, microbiological growth media, media makeup water, diagnostic sera.
Cosmetics: toiletries, aftershaves, perfumes, oils, lotions, creams, ointments, shampoos, body rinses, mouthwashes.
Fermentation Industries: liquid growth media, makeup water, intermediates, final liquid products, additives, exhaust gas, prefiltration.
Food and Beverage Industries: potable liquids, wine, beer, soft drinks, flavors, storage tank/reactor vents, corn syrup, edible oils.
Electronic Industries: photoresists, acids, bases, solvents, etchant gases, D.I. water prefiltration.
Performance
Liquid Service
Cartridge Grade | Liquid Removal1 Rating in Microns (μm) at % Efficiency | Aqueous Clean Pressure Drop2 Per 10 in. Module (PSI/GPM) | Typical Flow Rate Per 10 in. Module (GPM) | ||
90% | 99.98% | AB Style | UNI CAP Style | ||
J006 | – | <1.0* | 1.25 | 1.55 | 1-2 |
J012 | <1.0* | 1.2 | 0.22 | 0.31 | 2-3 |
J025 | <1.0* | 2.5 | 0.15 | 0.16 | 2-3 |
J045 | 1.2 | 4.5 | 0.11 | 0.12 | 2-3 |
J060 | 3.0 | 6.0 | 0.08 | 0.08 | 2-3 |
J100 | 5.4 | 10.0 | 0.06 | 0.06 | 3-5 |
J200 | 5.4 | 10.0 | 0.06 | 0.06 | 3-5 |
J400 | 22.0 | 40.0 | 0.02 | 0.02 | 5-8 |
J700 | 35 | 70.0 | 0.01 | 0.01 | 8-10 |
* Extrapolated value.
1 The test procedure used for liquid service rating is an adaptation of ANSI B93.31 - 1973, modified to determine the micron size above which particles are quantitatively removed.
2 Pressure drop in PSI per GPM water for a single 10" module. Multiply this value by the required flow to determine the total aqueous pressure drop. Next, for fluids other than water, multiply by viscosity in centipoise. If this calculated pressure drop is excessive, then divide this value by the number of 10" modules required to reduce this pressure drop to an acceptable level.
Type
Filter Cartridges
Additional Information
Housing Information
Housings are available in polypropylene, other polymers, carbon steel. Refer to brochure SUM 200 for further details.Ordering Information
This information is a guide to the part number structure and possible options. For availability of specific options and housing details, please contact Pall.
Example Part Number: PUY 1 J012 H13( See bold references in tables below)
HDC II "J" Series Element Part Number:
UNI CAP Element
PUY < Cartridge Length Code from Table 4 > < Grade Code from Table 5 > < Gasket Option Code from Table 2 >
Sanitary (AB) Style Element
AB < Cartridge Length Code from Table 4 > < Grade Code from Table 5 > < End Fittings Code from Table 6 > < Application Option Code from Table 3 > < O-Ring Option Code from Table 1 >
Example Part Number: PUY 1 J012 H13( See bold references in tables below)
HDC II "J" Series Element Part Number:
UNI CAP Element
PUY < Cartridge Length Code from Table 4 > < Grade Code from Table 5 > < Gasket Option Code from Table 2 >
Sanitary (AB) Style Element
AB < Cartridge Length Code from Table 4 > < Grade Code from Table 5 > < End Fittings Code from Table 6 > < Application Option Code from Table 3 > < O-Ring Option Code from Table 1 >
Table 1
Code | O-Ring Option |
H4 | Silicone (Standard) |
H | Viton A* |
J | Ethylene Propylene |
* Trademark of E.I. du Pont de Nemours and Co.
Table 2
Code | Gasket Option |
H13 | Buna N |
H | Viton A |
J | Ethylene Propylene (Std) |
Table 3
Code | Application Option |
Omit | Other |
P | Pharmaceutical |
Table 4
Code | Cartridge Lengths |
1 | 10 in. |
2 | 20 in. |
3 | 30 in. |
4 | 40 in. |
Table 5
Code | Grade: 99.98% Removal Rating (μm) |
J006 | <1.0* |
J012 | 1.2 |
J025 | 2.5 |
J045 | 4.5 |
J060 | 6.0 |
J100 | 10 |
J200 | 20 |
J400 | 40 |
J700 | 70 |
* Extrapolated Value
Table 6
End Fittings | ||
Code | O-Ring Fitting I.D. (In.) | O-Ring Replacement Size |
3 | 1.25 | -222 (Flat end) |
7 | 1.5 | -226 (Finned end & bayonet lock) |
8 | 1.25 | -222 (Finned end) |