UltiKleen™ Filters and KC Assemblies product photo Primary L

UltiKleen™ Filters and KC Assemblies

Description

Pall’s UltiKleen filter is an advanced all-fluoropolymer cartridge that is highly recommended for critical chemical filtration. Prewet filters are guaranteed extractable levels and particle cleanliness levels. The UltiKleen KC Assembly is a completely disposable filter unit, consisting of an all fluoropolymer UltiKleen filter.

Features

  • Utilizes an all fluoropolymer filter cartridge ensuring excellent effluent cleanliness
  • Eliminates O-rings for KC assemblies
  • Low differential pressure
  • Low extractable
  • Compatible with virtually all chemicals
  • 100% integrity tested
  • Available in In-line and T-flow styles
  • High pressure and temperature capability


Contact Us
* Required

Documents

Datasheets

Download: Chinese | English | Japanese

Description

Description

Pall’s UltiKleen filter is an advanced all-fluoropolymer cartridge that is highly recommended for critical chemical filtration. Prewet filters are guaranteed extractable levels and particle cleanliness levels. The UltiKleen KC Assembly is a completely disposable filter unit, consisting of an all fluoropolymer UltiKleen filter.

Features

  • Utilizes an all fluoropolymer filter cartridge ensuring excellent effluent cleanliness
  • Eliminates O-rings for KC assemblies
  • Low differential pressure
  • Low extractable
  • Compatible with virtually all chemicals
  • 100% integrity tested
  • Available in In-line and T-flow styles
  • High pressure and temperature capability

Specifications

Materials of construction1

 
Components Materials
Filter Medium PTFE
Media Support PTFE/PFA
Inner Core / Outer Cage PFA
End Caps PFA
Sealing methods Melt seal
O-ring (for cartridge) FEP Encapsulated fluoroelastomer
Housing (for KC type) PFA
 


1
All fluoro-polymer components made without PFOA.

 
Removal Ratings FD FT FR FX
0.05 μm 0.1 μm 0.2 μm 0.45 μm
Configurations (KC Assemblies) T-Flow, In-line
Configurations (Cartridge Filters) ABF04 AB1 AB2 AB3
Nominal Filter Areas 0.48 m2 / 5.17 ft2 1.2 m2 / 13 ft2 2.4 m2 / 26 ft2 3.6 m2 / 39 ft2
Nominal Length 102 mm / 4 in 254 mm / 10 in 508 mm / 20 in 762 mm / 30 in
Maximum Operating Temperature 170 ˚C / 338 ˚F
Maximum Forward Differential Pressure 0.59 MPa < 50 ˚C / 85 psid < 120 ˚F
Maximum Operating Pressure 0.49 MPaG ( < 25 ˚C / 77 ˚F)
0.39 MPaG ( < 60 ˚C / 140 ˚F )
0.34 MPaG ( < 90 ˚C / 194 ˚F )
0.20 MPaG ( < 120 ˚C / 248 ˚F )
0.15 MPaG ( < 150 ˚C / 302 ˚F)
0.12 MPaG ( < 170 ˚C / 338 ˚F )
 

Performance


UltiKleen™ Filters

Typical Flow Characteristics - 1cP fluid, 20 ºC



Type

Filter Capsules

Additional Information

Operating Recommendations

  • Available prewet as an option
  • Proper wetting procedures should be followed if prewet option is not selected. IPA or other low surface
    tension wetting liquids need to be completely flushed prior to chemical contact.
  • Must allow for proper venting

Dimensions



Part Numbers / Ordering Information2

ABF [1] UCF [2] 3EH1 [3]
MRF [1] UCF [2] 25EH1 [3]

Table 1

 
Code Cartridge Length
Nominal AB type MR type
04 4 in 130 mm / 5.1 in -
1 10 in 284 mm / 11.2 in 262 mm / 10.3 in
2 20 in 544 mm / 21.4 in 503 mm / 19.8 in
3 30 in 794 mm / 31.3 in -
 

Table 2

 
Code Removal Ratings
D 0.05 μm
T 0.1 μm
R 0.2 μm
X 0.45 μm
 

Table 3

 
Code Prewet Option
blank Without Prewet
-K3 Prewet filter ( packaged in DI water)
-K7 Prewet filter ( packaged in DI water), Low metal extractables3
 

2 Part numbers in conbination with all codes are not always availbale. Please contact Pall for the part number availability.
3 Please contact Pall on the extractable conditions.


UltiKleenTM KC Assemblies

Typical Flow Characteristics - 1cP fluid, 20℃

Dimensions by Configurations



Nominal Length

 
Length Tube size 3/4 in (Code 13) Tube size 1/2 in (Code 09)
L1 416 -
L2 281 -
L2 430 420
L4 292 282
L5 180 -
L6 105 106
 


UltiKleenTM KC Assemblies

Part Numbers / Ordering Information4

LDF [1] [2] UCF [3] [4] E [5] [6]

Table 1

 
Code Flow
T T-Flow
N In-Line
 

Table 2

 
Code Cartridge Size
1 10 in
05 5 in
 

Table 3

 
Code Removal Ratings
D 0.05 μm
T 0.1 μm
R 0.2 μm
X 0.45 μm
 

Table 4

 
Code Tube Size
095 1/2 in female
13 3/4 in female
 

Table 4

 
Code Connection Size
066 3/8 in male
086 1/2 in male
127 3/4 in male
648 3/8 in male
 

Table 5

 
Code Connections
1 20 series (Flowell)
2 Super Pillar Type (Nippon Pillar)
51 Flare style
69 FinalLock
71 Super Pillar 300 P series (Nippon Pillar)
72 Super Pillar 300 P series L type (Nippon Pillar)
8 60 series (Flowell)
 

Table 6

 
Code Prewet Option
blank Without Prewet
-K3 Prewet filter (packaged in DI water)
-K7 Prewet filter (packaged in DI water), Low metal extractables10
 


4
Disposable capsules are not available with every option. Please contact Pall for the part number availability.
5 Only for In-line type.
6 Only for flare style of In-line type.
7 Only for flare style. 8 Only for Super Pillar 300 series.
9 Only for T-flow type.
10 Contact your local Pall representative for information about extractables.