Documents
Datasheets
Download:Description
Continuous Length, Backflushable, Precoat, Condensate Filter
Hydro-Guard CoLD R filter elements are manufactured using the CoLD Melt™ fiber production process. The CoLD Melt process permits the creation of multiple filtration zones within a single filter cartridge. The reverse graded pore density, multi-zone design provides customers with even precoating, efficient backflushing, and long filter life. Many power plants around the world have switched from string wound technology to Hydro-Guard CoLD R products for improved condensate polishing.
Product Feature | Product Benefit | Customer Benefit |
Continuous Length Element |
|
|
Co-Located Large Diameter Melt Fibers |
|
|
Reverse Graded Pore Density Structure |
|
|
All Polypropylene Construction |
|
|
Specifications
Performance Specifications
Maximum operating temperature
65 °C (150 °F)
Maximum differential pressure
2.07 bard (30 psid) @ 65 °C (150 °F)
Typical Flow vs. Differential Pressure for Application Sizing1
Unit conversion: 1 bar = 14.5 psi
1 Flow rate is for a 152 cm/60 inch 30 μm cartridge. For liquids other than water, multiply differential pressure by fluid viscosity (cP).
Product Specifications
Materials of construction
Filter media: | Polypropylene |
End caps: | Polypropylene |
Sealing: | Thermal bond |
Gasket/O-ring material: | Sulfur-free EPDM (standard) |
Type
Filter Cartridges
Ordering Information
Pall Part Number = HGCOLDR [1]-[2]-P-[3]-[4]-[5]
Table 1
Code | Filter grades (μm) |
5 | 5 |
30 | 30 |
Table 2
Code | Cartridge lengths cm/in. |
50 | 127/50 |
60 | 152/60 |
70 | 178/70 |
80 | 203/80 |
Table 3
Code | Seal material |
E | Sulfur-free EPDM |
Table 4
Code | End configurations - bottom |
COOP | Fine threaded connection for bottom tube sheet vessels |
M8TVO | Extended neck, double O-ring seal for top tube sheet vessels |
PAK-F | One turn, easy install/remove connection with double seal integrity for bottom tube sheet vessels |
PBQ | Double-open-end filter for bottom tube sheet vessels |
End configurations - bottom
Table 5
Code | End configurations - top |
H | 3& ⁄8 HEX - 2.5 inch elongated hex nut and cotter pin for connection with vessel lattice strips |
S | 3& ⁄8 STUD - 1.5 inch threaded stud and either nut or cotter pin for connection with vessel lattice strips |
FIN | SPEAR - Bottom retaining devise for top tube sheet filters |
DOE | Double-open-end filter for top tube sheet vessels |
End configurations - top
Reviews