Description
Features:
- Coalescer to rapidly remove bulk-free water.
- Vacuum dehydration unit using mass transfer technology to remove up to 80% of dissolved water.
- High flow filtration using Pall Coreless Ultipor III filter elements to remove harmful particulate contamination.
- Simplified Design for low maintenance and ease of service.
- Customized skid fabrication for optimum flow rates.
Specifications
Guaranteed Performance
The Pall Turbine Lube Oil Conditioner eliminates free water, reduces dissolved water to 100 ppm, and removes particulates to ISO 16/14/12, or better.
Automated Operation
PLC controls with diagnostic automatic shutdown are standard on all units.
Startup Support
Factory representative is present during startup to provide assistance and perform fluid sampling for cleanliness qualification.
Rapid Reservoir Turnover Rate
Designed for high fluid flow rates, the Pall Turbine Lube Oil Conditioner produces reservoir turnover rates that meet or exceed OEM recommendations.
No Water Hookup Required
Optional moisture condenser is air cooled, eliminating the need for a dedicated water supply.
Reduced Oil Oxidation
Dissolved water removal is performed via vacuum dehydration. Therefore, the potentially harmful high heat requirement of flash distillation units is avoided.
Environmentally Friendly
The Turbine Lube Oil Conditioner incorporates Pall Coreless Ultipor III filter technology to reduce the disposal costs of landfilling oil soaked filter elements.
Features:
- Coalescer to rapidly remove bulk free water.
- Vacuum dehydration unit using mass transfer technology to remove up to 80% of dissolved water.
- High flow filtration using Pall Coreless Ultipor III filter elements to remove harmful particulate contamination.
- Simplified Design for low maintenance and ease of service.
Customized skid fabrication for optimum flow rates.
Performance
Flow Schematic
Type
Ordering Information
Part Number: |
TLC |
|
|
|
|
||||
|
|
Table1 |
Table2 |
Table3 |
Table4 |
|
|
|
|
Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: FLOW RATE OPTION |
|
|
|
Code
|
Flow Rate
|
---|---|
|
|
125
|
125 gpm
|
|
|
200
|
200 gpm
|
|
|
290
|
290 gpm
|
|
TABLE 2: VACUUM DEHYDRATION PURIFIER OPTION |
|
|
|
Code
|
Purifier Model
|
---|---|
|
|
V9
|
HVP 902
|
|
|
V27
|
HVP 2702
|
|
TABLE 3: COALESCER OPTION |
|
|
|
Code
|
Coalescer
|
---|---|
|
|
C
|
Included
|
|
|
N
|
Not Included
|
|
TABLE 4: SUPPLY VOLTAGE OPTION |
|
|
|
Code
|
Voltage
|
---|---|
|
|
Omit
|
460V
|
|
|
575
|
575V
|
|
|
380
|
380V
|
|
CONFIGURATION |
||||||
Model
|
Filter Housings
|
Overall Dimensions
|
Port Size
|
|||
Width
|
Length
|
Height
|
Inlet
|
Outlet
|
||
125*
|
1-8314 series
|
84"
|
94"
|
85"
|
4"
|
2-1/2"
|
200*
|
2-8314 series
|
94"
|
94"
|
85"
|
5"
|
3-1/2"
|
290**
|
3-8314 series
|
71"
|
130"
|
85"
|
6"
|
4"
|
* With HVP 902 purifier.
**With HVP 2702 purifier.
Reviews