Gas Filters

Sterilizing-grade gas filters protect biopharmaceutical products from contamination by microorganisms or particles during processes such as gas venting from tanks or bioreactors, compressed gas filtration and high-temperature or highly oxidizing applications. Non-sterilizing-grade filters reduce bioburden for non-critical applications or act as prefilters protecting a sterilizing-grade filter downstream.

 

Shop Gas Filters

 

Emflon II

Emflon® PFR

Emflon HTPFR

HDC II

Emflon PFA

Order Products

Brand

Poly-Fine®

Filter Media

Polypropylene

Profile® UP, Filter Cartridges, Removal Rating 6 μm, Length 30 Inches

Product ID: AB3UY0607J
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
6 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Ethylene Propylene
See All Attributes

Profile® UP, Filter Cartridges, Removal Rating 10 μm, Length 30 Inches, FluorocarbonElastomer

Product ID: AB3UY1007H
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Fluorocarbon Elastomer
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 20 Inches, EPDM

Product ID: ARD0520UEDOE
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 10 Inches

Product ID: ARD1010UH21
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
End Configuration Code
H21
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 10 Inches, EPDM, DOE with elastomer gasket seals and end caps

Product ID: ARD1010UEDOE
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 10 Inches, EPDM, SOE flat closed end external 222 O-rings

Product ID: ARD1010UEM3
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
EPDM
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 20 Inches

Product ID: ARD1020UH21
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
End Configuration Code
H21
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 10 μm, Polypropylene, Length 30 Inches

Product ID: ARD1030USM3
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 10 Inches, Nitrile

Product ID: ARD110UNDOE
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Nitrile
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 20 Inches, DOE Santoprene gasket seal

Product ID: ARD120UH21
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
End Configuration Code
H21
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 10 Inches, Expanded PTFE gaskets FEP encapsulated silicone O-rings

Product ID: ARD110UTM8
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket / O-Ring Material
Expanded PTFE (gaskets) FEP encapsulated silicone (O-rings)
See All Attributes

Poly-Fine® ARD, Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 39 Inches

Product ID: ARD139UNDOE
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
39 in
Cartridge Length (Metric)
991 mm
Cartridge Length (Metric)
99.1 cm
Gasket / O-Ring Material
Nitrile
See All Attributes

Description

Pall® Gas Filter Comparisons

 

Family/Grade

Emflon II 

Emflon PFR

Emflon HTPFR

HDCII

Emflon PFA

Membrane part number reference

V002

PFR

HTPFR

J

PFA

Membrane material

 

Polyvinyl fluoride (PVDF)

Polytetrafluoroethylene (PTFE)

Polytetrafluoroethylene (PTFE)

Polypropylene (PP)

Polytetrafluoroethylene (PTFE)

Support and drainage layer/ core/cage/endcap material

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

 

Polypropylene

Gamma Sterilizable?

Yes

No

No

No

No

Steam and Autoclave Sterilizable?

Yes

Yes

Yes

Yes

Yes

Pore size (µm)

0.2

0.2

0.2

1.2 – 10

0.2

Suitability for highly oxidative environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good

Suitability for high temperature environments

 

Good

 

Very Good

 

Excellent

 

Good

 

Good




For sterilizing-grade gas filtration in single-use systems

 

Emflon® II PVDF sterilizing-grade membrane gas filters are used in single-use systems and are validated for gamma irradiation. Emflon II filter capsules can be supplied either pre-sterilized by gamma irradiation or non-sterilized for sterilization by gamma irradiation/autoclave by the end user.

 

For sterilizing-grade gas filtration in stainless steel systems

 

Emflon® PFR PTFE sterilizing-grade membrane filter cartridges and capsules are used in nitrogen blanketing or compressed gas applications for stainless steel bioreactors and filling operations.  The hydrophobic and chemically inert filter membranes meet the FDA requirements for microbial removal to qualify as sterilizing-grade. These filters have high strength and long life under 60°C.

 

For high-temperature, ozonated-water venting and oxygen-enriched applications

 

Emflon® HTPFR PTFE sterilizing-grade membrane filter cartridges are specially designed for gas filtration in highly oxidizing applications such as oxygen enrichment of bioreactors, or process steps with temperatures above 60 °C, such as autoclaves, fermentation inlet air, aseptic packaging/ blow-fill-seal and WFI tank vents. The Emflon HTPFR cartridges have an oxidation-resistant structure that has been validated for extended use at elevated temperatures or in highly oxidizing applications.

 

Prefilter

 

HDC® II PP filters are used for prefiltration to protect sterilizing-grade filters.  They can also be used in fine particle applications where purity, reliability, and economy are critical.  All-polypropylene filter capsules and cartridges incorporate proprietary HDC II tapered pore polypropylene depth media and are available in a range of different formats. 

 

Bioburden

 

Emflon® PFA PTFE filters can be used in bioburden applications where a sterilizing-grade filter isn’t required.  These gas filter cartridges offer the highest levels of bioburden reduction, and high flow rates combined with a high filter area per 254 mm (10 in.) cartridge.

Applications

 

Application

Recommended Filter

Sterilizing-grade for single-use systems

Emflon® II

Sterilizing-grade for stainless steel systems

Emflon® PFR

Sterilizing-grade for high-temperature, ozonated-water venting, and oxygen enriched applications

Emflon® HTPFR

Prefilter for protection of sterilizing-grade gas filters

HDC® II

Bioburden reduction for high flow applications

Emflon® PFA

 


Need more help choosing the right filter? 

 

Our Scientific and Laboratory Services (SLS) team have been helping our customers optimize their processes for more than 50 years. Together with our wide range of filter membranes, we can find the right filtration solution or help to optimize your sterile filtration process. 

 

Contact us via the web form at the bottom of this page to request a consultation with one of our sterile filtration specialists to discuss your process and offer free support to help you get it right.

 

Documents

Application Notes

  • Safety Considerations for Gas Filtration in High-Temperature and Oxygen Enrichment Applications

    Select Language :
  • Best Practices For Successful Filter Integrity Testing Using The Water Intrusion Test (WIT) Method

    Select Language :
  • Identifying False Failures Using the Water Intrusion Test

    Select Language :
  • How to Select the Right Filter Integrity Test Instrument

    Select Language :
  • Sterile Vent Filtration on Ozonated Water Tanks

    Select Language :
  • Sterilizing Filtration of Enriched and Pure Gaseous Oxygen Employed in Cell Culture Applications

    Select Language :
  • Meeting Regulatory Requirements for Vent Filtration on Water For Injection (WFI) Tanks

    Select Language :